WATSON INDUSTRIES VSG-E469 Owner's Manual - page 4
Watson Industries, Inc.
VSG Bipolar Rev E 02/15/2008
The wire bundle is shielded and connected to the VSG case. Watson Industries
recommends that you do not connect to the shield.
The case of the VSG is not hermetically sealed. Avoid the possibility of moisture
entering the case.
The power ground is already connected internally to the signal ground. Do not
connect the ground wires externally.
The VSG, although of rugged design, is a sensitive instrument. Take care when
handling it.
4.
Typical Operating Circuits
Figure 3: Typical Configurations
+ RATE GIVES
+ OUTPUT VOLTAGE
VSG
Angular Rate Output
Power Ground
Signal Ground
Load (min)
100 kΩ
Output: 0 V ± S/F * Rate Input
+5 V Ref.
Angular Rate Output
Ref. In
ADC
(i) Bipolar Output
(ii) Digital Output
Power Ground
VSG
Red
Blue
Green
Black
Black
Blue
Orange
V +
Red
+V