Watson-Marlow 520DUN User Manual - 22.12 Outputs 1, 2, 3, 4

Manual is about: IP66/NEMA 4X pumps

Summary of 520DUN

  • Page 1

    Watson-marlow 520dun ip66/nema 4x user manual 1 watson-marlow bredel manuals watson-marlow 520dun ip66/nema 4x pumps m-520dun-4x-gb-05 contents 1 declaration of conformity 3 2 declaration of incorporation 3 3 five-year warranty 4 4 when you unpack your pump 5 5 information for returning pumps 6 6 pe...

  • Page 2

    Watson-marlow 520dun ip66/nema 4x user manual 2 29.2 520r and 520r2 tube loading 84 29.3 520re: fitting the drain port 85 29.4 520re element loading 86 29.5 520re element connection 88 30 520r, 520r2 and 520re maintenance 89 31 520r, 520r2 and 520re rotor settings 90 32 pumphead spares 91 33 flow ra...

  • Page 3: 1 Declaration of Conformity

    Watson-marlow 520dun ip66/nema 4x user manual 3 1 declaration of conformity this declaration was issued for watson-marlow 720dun pumps on may 1, 2007. When this pump unit is used as a stand-alone pump it complies with: machinery directive 2006/42/ec, emc directive 2004/108/ec. This pump is etl liste...

  • Page 4: 3 Five Year Warranty

    Watson-marlow 520dun ip66/nema 4x user manual 4 3 five year warranty 520 cased pumps, 620 cased pumps and 720 cased pumps for any 520, 620 or 720 cased pump purchased after 1 january 2007, watson- marlow limited (“watson-marlow”) warrants, subject to the conditions and excep- tions below, through ei...

  • Page 5: 4 When You Unpack Your Pump

    Watson-marlow 520dun ip66/nema 4x user manual 5 4 when you unpack your pump unpack all parts carefully, retaining the packaging until you are sure all components are present and in good order. Check against the components supplied lists, below. Packaging disposal dispose of packaging materials safel...

  • Page 6

    Watson-marlow 520dun ip66/nema 4x user manual 6 storage this product has an extended shelf life. However, care should be taken after storage to ensure that all parts function correctly. Users should be aware that the pump con- tains a battery with an unused life of seven years. Long-term storage is ...

  • Page 7

    Watson-marlow 520dun ip66/nema 4x user manual 7 6 peristaltic pumps - an overview peristaltic pumps are the simplest possible pump, with no valves, seals or glands to clog or corrode. The fluid contacts only the bore of a tube, eliminating the risk of the pump contaminating the fluid, or the fluid c...

  • Page 8: 7 Safety Notes

    Watson-marlow 520dun ip66/nema 4x user manual 8 7 safety notes in the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have read and understood this manual, and considered any hazard involved. If the pump is used in a mann...

  • Page 9

    Watson-marlow 520dun ip66/nema 4x user manual 9 there are moving parts inside the pumphead. Before opening the tool- unlockable pumphead guard, ensure that the following safety directions are fol- lowed. Ensure that the pump is isolated from the mains power. Ensure that there is no pressure in the p...

  • Page 10: 8 Pump Specifications

    Watson-marlow 520dun ip66/nema 4x user manual 10 8 pump specifications labels fixed to the rear of the pump contain manufacturer and contact details, prod- uct reference number, serial number and model details. The same information is carried on the drive’s backplate, accessible when the 520n module...

  • Page 11

    Watson-marlow 520dun ip66/nema 4x user manual 11 520dun, ip66 nema 4x model this pump can be controlled from the keypad or remotely. It features: manual control speed adjustment; run and stop; direction control; keypad scaling; “max” key for rapid priming. Remote control the pump can be digitally co...

  • Page 12

    Watson-marlow 520dun ip66/nema 4x user manual 12 ip (ingress protection) and nema definitions * 520n cased pumps are rated to nema 4x (indoor use) only. Ip nema 1st digit 2nd digit 3 protected against ingress of solid objects with a diameter of more than 2.5mm. Tools, wires etc with a thickness of m...

  • Page 13

    Watson-marlow 520dun ip66/nema 4x user manual 13 pump specifications control range (turndown ratio) 0.1-360rpm (3,600:1) supply voltage/frequency 100-120v/200-240v 50/60hz 1ph maximum voltage fluctuation ±10% of nominal voltage. A well regulated electrical mains supply is required along with cable c...

  • Page 14

    Watson-marlow 520dun ip66/nema 4x user manual 14 standards ec harmonised standards safety of machinery—electrical equipment of machines: bs en 60204-1 safety requirements for electrical equipment for measurement, control and laboratory use: bs en 61010-1 incorporating a2 category 2, pollution degree...

  • Page 15: 8.1 Dimensions

    Watson-marlow 520dun ip66/nema 4x user manual 15 8.1 dimensions unit weights 520dun ip66/nema 4x model drive only + 520r, 520r2 + 520rel, 520rem, 520reh + 505l ip66 nema 4x 10.58kg 23lb 5oz 11.48kg 25lb 5oz 11.40kg 25lb 2oz 13.06kg 28lb 13oz.

  • Page 16: 9.1 General Recommendations

    Watson-marlow 520dun ip66/nema 4x user manual 16 9 good pump installation practice 9.1 general recommendations a correctly engineered installation will promote long tube life. Site the pump on a flat, horizontal, rigid surface, free from excessive vibration, to ensure correct lubri- cation of the ge...

  • Page 17

    Watson-marlow 520dun ip66/nema 4x user manual 17 do not strap the control and mains power cables together. Do keep delivery and suction tubes as short and direct as possible - though ideally not shorter than 1m - and follow the straightest route. Use bends of large radius: at least four times the tu...

  • Page 18: 10 Connecting This Product

    Watson-marlow 520dun ip66/nema 4x user manual 18 10 connecting this product to a power supply the voltage selector is mounted in the switchplate at the rear of the pump, protected from water by the 520n module. The module must be removed to allow access to the switchplate. See 22.1 520n module fit- ...

  • Page 19

    Watson-marlow 520dun ip66/nema 4x user manual 19 if the mains power cable is inappropriate for your installation, it can be changed. This operation can be carried out with the 520n module in place, or after it has been removed, as shown here for clarity. Ensure that the pump is isolated from the mai...

  • Page 20

    Watson-marlow 520dun ip66/nema 4x user manual 20 input line fusing: type t2,5a h 250v 20mm time-delayed fuse, located in a fuseholder in the centre of the switch- plate at the rear of the pump. Power interruption: this pump has an auto-restart feature which, when active, will restore the pump to the...

  • Page 21: 11 Start-Up Check List

    Watson-marlow 520dun ip66/nema 4x user manual 21 11 start-up check list note: see also 29.2 tube loading. Ensure that proper connections are achieved between the pump tube and suc- tion and discharge piping. Ensure proper connection has been made to a suitable power supply. Ensure that the recommend...

  • Page 22

    Watson-marlow 520dun ip66/nema 4x user manual 22 first-time start-up defaults language not set analogue input 4-20ma speed maximum user trim none direction clockwise remote stop open=run pumphead 520r pump number 1 tube size 9.6mm baud rate 9600 calibration from head and tube table stop bits 2 backl...

  • Page 23: 13 Switching The Pump On

    Watson-marlow 520dun ip66/nema 4x user manual 23 13 switching the pump on in subsequent power cycles (if not in auto-restart mode) switch on the power supply at the rear of the pump. The pump runs a power- on test to confirm proper functioning of the memory and hardware. If a fault is found, an erro...

  • Page 24: 14 Manual Operation

    Watson-marlow 520dun ip66/nema 4x user manual 24 14 manual operation 14.1 keypad functions in manual mode all settings and functions of the pump in manual mode are set and controlled by means of key-presses. Immediately after the start-up display sequence detailed above, the manual mode main screen ...

  • Page 25

    Watson-marlow 520dun ip66/nema 4x user manual 25 max: while pressed, max operates the pump at the maximum allowed speed and in the direction shown on the display. When released, the pump returns to its previous status. Note: priming can be achieved by pressing the max key until fluid flows through t...

  • Page 26

    Watson-marlow 520dun ip66/nema 4x user manual 26 enter: cycles the information shown on the manual mode main screen from revolutions per minute, to flowrate in a choice of units (via a warning screen if flowrate has not been calibrated) to rpm, flowrate and run time. (see start, above. See 17 calibr...

  • Page 27: 14.2 Keypad Lock

    Watson-marlow 520dun ip66/nema 4x user manual 27 14.2 keypad lock the keypad can be locked to prevent changes to pump speed or other settings, and make it possible only to start or stop the pump. The padlock symbol shows on the display. While the pump is running, hold down the start key for two seco...

  • Page 28: 15 Main Menu

    Watson-marlow 520dun ip66/nema 4x user manual 28 15 main menu 15.1 keypad functions in menu screens in addition to their functions in other operations, the following keys have specific actions in menu screens: stop: in general, stop functions as a “go back” key, taking the user up one menu level wit...

  • Page 29: 15.2 Main Menu Entry

    Watson-marlow 520dun ip66/nema 4x user manual 29 15.2 main menu entry the menu key displays the main menu. It operates at any point in the pump’s activ- ity except where error screens are displayed, or screens where up and down keys are used to enter values. The main menu offers five options: calibr...

  • Page 30

    Watson-marlow 520dun ip66/nema 4x user manual 30 16 pin-secure process protection the 520dun and 520du feature pin-secure process protection. This allows the pump to be configured to suit the application, and for the setup to be protected by two levels of pin code. See 18.19 security code setup. * w...

  • Page 31: 17 Calibrate

    Watson-marlow 520dun ip66/nema 4x user manual 31 17 calibrate the pump can display flowrate in a choice of units as well as speed in revolutions per minute. It must first be calibrated. Pump calibration can be limited to users who correctly enter a three-digit security code. If a security code has b...

  • Page 32

    Watson-marlow 520dun ip66/nema 4x user manual 32 head and tube if head and tube is selected, the pump displays a list of standard pumpheads that can be fitted to the pump. It occupies two screens. Use the up and down keys to move the highlight down the list. When the last item on the first screen is...

  • Page 33

    Watson-marlow 520dun ip66/nema 4x user manual 33 calibration dose the pump offers to run a calibration dose. Use the up and down keys to choose yes or no. Press enter to confirm. Examples are shown here. If no is selected after a tube selection has been made (see tube above), the pump briefly displa...

  • Page 34

    Watson-marlow 520dun ip66/nema 4x user manual 34 measure the quantity of fluid dispensed. The pump displays its calculated dose, based on previous calibration data. Use the up and down keys to adjust this reading to match the measured volume. Press enter. The pump displays the new head, tube and flo...

  • Page 35: 18 Setup

    Watson-marlow 520dun ip66/nema 4x user manual 35 18 setup entry to the setup menu can be limited to users who correctly enter a three-digit security code. If a security code has been set, selecting setup and confirming with the enter key causes the pump to display the security code entry sequence. S...

  • Page 36: 18.1 Trim

    Watson-marlow 520dun ip66/nema 4x user manual 36 18.1 trim when the pump is under remote control, it tracks an analogue signal from the user’s remote control system to the i/p terminal of the analogue 1 and analogue 2 con- nectors at the rear of the pump within the ranges 4-20ma or 0-10v. The trim s...

  • Page 37: 18.2 Analogue

    Watson-marlow 520dun ip66/nema 4x user manual 37 the final press on enter ends the analogue 1 trimming sequence. If analogue 2 has been configured, the pump displays a similar sequence of screens for that input. Apply the low, high and mid-range signal to the i/p terminal of the analogue 2 connector...

  • Page 38

    Watson-marlow 520dun ip66/nema 4x user manual 38 input 1 - speed allows the user to tell the pump which signal type he will apply to analogue 1, or to choose the program option. If he selects program from the sub- sequent menu, the user can choose his input type and tell the pump the speeds at which...

  • Page 39

    Watson-marlow 520dun ip66/nema 4x user manual 39 program select program using the up or down keys and press enter to confirm. The pump offers two choices: ma and v. Use the up or down keys to make a selection and press enter to confirm your decision. The pump displays a screen allowing you to set th...

  • Page 40

    Watson-marlow 520dun ip66/nema 4x user manual 40 scaling - stroke select scaling - stroke using the up or down keys and press enter to confirm your choice. The pump offers five further choices: off, keypad, 4-20ma, 0-10v and program. Use the up or down keys to make a selection and press enter to con...

  • Page 41: 18.3 Display

    Watson-marlow 520dun ip66/nema 4x user manual 41 18.3 display the pump can display three default screens in manual mode: revolutions per minute, flowrate in a choice of units, or both. In the first screen of the setup menu select display using the up and down keys. Press enter to confirm your choice...

  • Page 42: 18.4 Pump Number

    Watson-marlow 520dun ip66/nema 4x user manual 42 18.4 pump number the 520dun pump can be individually controlled under rs485 as one of up to 32 pumps. First it must be given its identity number. In the first screen of the setup menu select pump no 1 using the up and down keys. Press enter to confirm...

  • Page 43: 18.6 Stop Bits

    Watson-marlow 520dun ip66/nema 4x user manual 43 18.6 stop bits the 520dun pump can be set to communicate with control devices at a choice of stop bits settings. In the second screen of the setup menu select stop bits using the up and down keys. Press enter to confirm your choice. The pump displays ...

  • Page 44: 18.8 Flow Units

    Watson-marlow 520dun ip66/nema 4x user manual 44 18.8 flow units the 520dun pump can display its flow rate in metric (si) or us (imperial) units of volume or mass. In the second screen of the setup menu select flow units using the up and down keys. Press enter to confirm your choice. The pump displa...

  • Page 45: 18.9 Run Time

    Watson-marlow 520dun ip66/nema 4x user manual 45 if you chose a volumetric flow rate from either screen, a confirmation screen appears briefly and the pump displays the second screen of the setup menu. If you chose a mass flow rate from either screen, the pump asks for the specif- ic gravity of the ...

  • Page 46: 18.10 Outputs

    Watson-marlow 520dun ip66/nema 4x user manual 46 18.10 outputs the 520dun pump offers four relay status outputs. See 12 switching the pump on for the first time for initial startup defaults. Each of five parameters can be config- ured to any output, or more than one output. The parameters are: run /...

  • Page 47

    Watson-marlow 520dun ip66/nema 4x user manual 47 in the third screen of the setup menu select outputs using the up and down keys. Press enter to confirm your choice. The pump displays a screen allowing you to configure each of the four outputs, or to exit this menu. Use the up and down keys to choos...

  • Page 48: 18.11 Remote Stop

    Watson-marlow 520dun ip66/nema 4x user manual 48 18.11 remote stop the 520dun pump can be started and stopped with a remote switch between the 5v terminal and the i/p terminal of the run/stop input, using an open=run or open=stop command sense. It also operates with a logic input between 5v and 24v ...

  • Page 49

    Watson-marlow 520dun ip66/nema 4x user manual 49 if yes is chosen, the pump asks the user whether the remote stop feature is to be disabled fully (for both manual and auto operation), or only for manual operation, leaving remote stop functioning when the pump is operating in auto mode. Choose using ...

  • Page 50: 18.12 Auto-Restart

    Watson-marlow 520dun ip66/nema 4x user manual 50 18.12 auto-restart this pump offers an auto-restart feature. If active on power loss, it restores the pump when power returns to the operating state it was in when power was lost. It does not operate when powering down in the middle of a dose: when th...

  • Page 51: 18.13 Set Maximum Speed

    Watson-marlow 520dun ip66/nema 4x user manual 51 18.13 set maximum speed the 520dun pump offers a maximum speed of 220 revolutions per minute. This limit can be reduced for operational purposes. In the fourth screen of the setup menu select set max speed using the up and down keys. Press enter to co...

  • Page 52: 18.15 Rom

    Watson-marlow 520dun ip66/nema 4x user manual 52 18.15 rom the pump can display its software version, model number and pump speed. In the fourth screen of the setup menu select rom using the up and down keys. Press enter to confirm your choice. The pump displays the software version, model number an...

  • Page 53: 18.17 Defaults

    Watson-marlow 520dun ip66/nema 4x user manual 53 18.17 defaults all the pump’s user-set data can be reset to factory defaults. In the fifth screen of the setup menu select defaults using the up and down keys. Press enter to confirm your choice. A warning is displayed for four seconds, and the pump a...

  • Page 54: 18.19 Security Code

    Watson-marlow 520dun ip66/nema 4x user manual 54 18.19 security code access to the pumpís setup menu, direction control and keypad lock can be restrict- ed to those who correctly enter a three-digit security code: the main code. A sec- ondary user code can be set, which permits pin access to directi...

  • Page 55: 18.20 Exit

    Watson-marlow 520dun ip66/nema 4x user manual 55 if you chose cancel codes, any codes previously set are cancelled and access to the pump is not restricted. If you chose set main code or set user code, the pump displays a screen with three blank spaces for digits and the instruction “enter new code”...

  • Page 56: 20 Memodose

    Watson-marlow 520dun ip66/nema 4x user manual 56 20 memodose each time the pump is started by pressing start, it records the number of pump- head revolutions which occur until stop is pressed. The number of revolutions is proportional to the volume of fluid which has been dispensed: the dose. The me...

  • Page 57: 20.1 Changing Dosing Speed

    Watson-marlow 520dun ip66/nema 4x user manual 57 to repeat the dose the pump has recorded the number of pumphead revolutions required to dis- pense the master dose. If the volume of fluid in the measuring vessel is the volume required, press start to repeat the dose. If the volume of fluid in the me...

  • Page 58: Memodose

    Watson-marlow 520dun ip66/nema 4x user manual 58 press the stop key twice within half a second to return to memodose. The dis- play shows the previous percentage dose size. The pump will dose at the new speed. Note: to retain the memodose value through a power interruption the pump must be in auto-r...

  • Page 59: 22 Automatic Control Wiring

    Watson-marlow 520dun ip66/nema 4x user manual 59 22 automatic control wiring interfacing the pump with other devices is by means of screw-terminal connectors within the 520n watertight module at the rear of the pump. Suitable cable must be passed into the module through one or more watertight cable ...

  • Page 60

    If necessary, unplug the two 25-way d-connectors linking the module to the pump drive. If necessary, remove the module’s earth link from the back of the drive. However, the link is long enough to allow the module to fold back to give access to the the circuit board inside and to the back of the driv...

  • Page 61: 22.2 Wiring Up

    Watson-marlow 520dun ip66/nema 4x user manual 61 22.2 wiring up it is the user’s responsibility to ensure the pump’s safe and reliable operation under remote and automatic control. The 0v lines on this pump are commoned and mains transformer-isolated from ground (floating ground). It can be connecte...

  • Page 62

    Watson-marlow 520dun ip66/nema 4x user manual 62 suitable cables for general-purpose use: 300v with extra premium grade pvc jack- et with good flame and moisture resistance. Suitable cables for industrial use: 300v extra-rugged polyurethane grade jacket with resistance to oils, fuels, solvents and w...

  • Page 63

    Watson-marlow 520dun ip66/nema 4x user manual 63 strip the outer sheath as necessary and remove 5mm of insulation from the conductors. No tinning or ferrule is required. Note: if very stiff or large-diame- ter cable is used, it may be convenient to strip the outer sheath before passing the cable’s c...

  • Page 64: 22.3 Speed: Analogue Input

    Watson-marlow 520dun ip66/nema 4x user manual 64 22.3 speed: analogue input it is possible to control the speed of the pump remotely by one of these methods: a voltage analogue signal within the range 0-10v; or a current analogue signal within the range 4-20ma; or a remote potentiometer using the 10...

  • Page 65: 22.4 Scaling: Analogue Input

    Watson-marlow 520dun ip66/nema 4x user manual 65 22.4 scaling: analogue input it is possible to scale the speed of the pump remotely by one of these methods: a voltage analogue signal within the range 0-10v; or a current analogue signal within the range 4-20ma; or a remote potentiometer using the 10...

  • Page 66: 22.5 Speed: Analogue Output

    Watson-marlow 520dun ip66/nema 4x user manual 66 22.5 speed: analogue output an analogue voltage output signal is available on the tacho output connector (j11), between the v terminal and the 0v terminal. The voltage is fixed and directly proportional to the pumphead rotation speed. 0v = zero speed;...

  • Page 67: 22.7 Run / Stop Input

    Watson-marlow 520dun ip66/nema 4x user manual 67 important: general instructions for remote control inputs all remote control inputs can be wired in two ways: logic a logic voltage between 5v ttl and 24v industrial logic may be wired to the input. The pump is configured to operate without modificati...

  • Page 68: 22.10 Memodose Input

    Watson-marlow 520dun ip66/nema 4x user manual 68 22.9 auto / manual toggle input connect a remote switch between the +5v terminal and the i/p terminal of the auto-man i/p connector (j1). Closed switch for automatic control; open switch for man- ual control. Alternatively a logic input may be applied...

  • Page 69: 22.12 Outputs 1, 2, 3, 4

    Watson-marlow 520dun ip66/nema 4x user manual 69 important: pump status outputs outputs 1-4 are available as single-pole change-over relay contacts: relay 1, 2, 3 and 4. Connect to the normally open or normally closed contacts of the relay as required and configure the pump’s software accordingly. S...

  • Page 70: 22.14 Rs485 Input

    Watson-marlow 520dun ip66/nema 4x user manual 70 dc voltage max load typical use +5v 10ma voltage supply for inputs using remote switch. Possible voltage supply for outputs if only 5v is required. +12v 10ma possible voltage supply for inputs using remote switch. Possible voltage supply for outputs. ...

  • Page 71

    Watson-marlow 520dun ip66/nema 4x user manual 71 23 automatic control and operation check that the pump is ready to run before selecting automatic operation. Remote control signals may start the pump without warning. How to get into auto operation while the maunal mode main screen is displayed, pres...

  • Page 72

    Watson-marlow 520dun ip66/nema 4x user manual 72 the pump is automatically switched into auto-restart mode and displays the ! Icon. The only keys active are stop, auto/man, direction and start (available only as an extended keypress to toggle keypad lock). Up and down keys are available if manual sc...

  • Page 73

    Watson-marlow 520dun ip66/nema 4x user manual 73 emergency stop in an emergency press the stop key. The pump stops and displays an inter- ruption screen. If keypad lock is in place when stop is pressed, or if the pump is in auto mode via the digital input, the interruption screen offers one key-pres...

  • Page 74

    Watson-marlow 520dun ip66/nema 4x user manual 74 24 network control and operation check that the pump is ready to run before selecting network operation. Remote control signals may start the pump without warning. How to get into network operation while the maunal mode main screen is displayed, press...

  • Page 75

    Watson-marlow 520dun ip66/nema 4x user manual 75 how to get out of network operation pressing the auto/man key displays three options: analogue, manual and network. Use the up and down keys to choose and press enter to con- firm. Selecting manual sets the pump to manual operation and retains the set...

  • Page 76: 24.1 Rs485 Command Strings

    Watson-marlow 520dun ip66/nema 4x user manual 76 24.1 rs485 command strings command parameters meaning nca - clear lcd display nch - home the cursor ndo xxxxxxxxxx set and run one dose of xxxxxxxxxx tacho pulses, with optional drip of yyyyy (maximum 11,000) tacho pulses. See note 1 ntc - clear the c...

  • Page 77: 25 Troubleshooting

    Watson-marlow 520dun ip66/nema 4x user manual 77 25 troubleshooting if the pump display remains blank when the pump is on, make the following checks: check the position of the voltage selector switch. The voltage selector is mounted in the switchplate at the rear of the pump, protected from water by...

  • Page 78: 25.1 Error Codes

    Watson-marlow 520dun ip66/nema 4x user manual 78 25.1 error codes if an internal error occurs, a flashing error screen is displayed. Note: signal out of range, over signal, no signal and leak detected error screens report the nature of an external signal. They do not flash. Error condition suggested...

  • Page 79: 26 Drive Maintenance

    Watson-marlow 520dun ip66/nema 4x user manual 79 26 drive maintenance there are no user serviceable parts inside the pump (except the power cable: see 10 connecting this product to a power supply). The unit should be returned to watson-marlow or its appointed agents or distributors for service. 27 d...

  • Page 80: 28 The 520R, 520R2 and 520Re

    Watson-marlow 520dun ip66/nema 4x user manual 80 28 the 520r, 520r2 and 520re pumpheads identification of parts 1 guard latch 5 rotor cap 9 pumping roller 2 guard (520r, 520r2) 6 tube guide roller 10 tube clamp slider (520r, 520r2) 3 track 7 rotor 11 tube clamp (520r, 520r2) 4 clutch button cover 8 ...

  • Page 81: Replacement

    Watson-marlow 520dun ip66/nema 4x user manual 81 28.1 pumphead position, removal and replacement the pumphead track can be fitted in one of three orientations to provide right, up or down input/output port positions, whichever is convenient. Position the pump- head so that the tube ports face up or ...

  • Page 82

    Watson-marlow 520dun ip66/nema 4x user manual 82 rotor removal remove any tubing from the pumphead. Open the flexible rotor cap in the centre of the rotor. Undo and withdraw the central locating screw using a slotted screwdriver. Pull the rotor hub off its dogged shaft. Between the hub and the shaft...

  • Page 83: 29 520R, 520R2 and 520Re

    Watson-marlow 520dun ip66/nema 4x user manual 83 29 520r, 520r2 and 520re installation 29.1 opening the pumphead guard unlock the pumphead guard by turning the guard fastener 1 ⁄ 4 turn anticlockwise with a slotted screwdriver. Open the guard to its full extent to create maximum clearance for the tu...

  • Page 84

    Watson-marlow 520dun ip66/nema 4x user manual 84 29.2 520r and 520r2 tube loading 520r continuous tubing pumpheads are factory-set to accept watson-marlow 1.6mm-wall tubing. 520r2 continuous tubing pumpheads are factory set to accept watson-marlow 2.4mm-wall tubing. Pumping performance may be advers...

  • Page 85

    Watson-marlow 520dun ip66/nema 4x user manual 85 the spring-loaded tube clamps must grip the tubing tightly enough to stop it moving in and out of the pumphead but must not over-squeeze the tube and throttle fluid flow. The tubing clamps are fitted with yellow sliders which can be clicked into two p...

  • Page 86: 29.4 520Re Element Loading

    Watson-marlow 520dun ip66/nema 4x user manual 86 29.4 520re element loading 520re tubing element pumpheads are factory-set to accept watson-marlow 2.4mm- wall tubing elements. Elements fitted with either quick-release industrial connectors or tri-clamp sanitary connectors may be used; however, it is...

  • Page 87

    Watson-marlow 520dun ip66/nema 4x user manual 87 check that the conical connector sleeve of the element to be fitted is the same colour as the pumphead rotor cap 520re element loading procedure note: the element loading procedure is the same for industrial (pictured) and san- itary elements. Select ...

  • Page 88

    Watson-marlow 520dun ip66/nema 4x user manual 88 29.5 520re element connection select suitable tubing to connect to the tubing element supply and discharge con- nectors. Check that its pressure rating is appropriate to the application. Sanitary 3 ⁄ 4 in mini-tri-clamp connectors sanitary connectors ...

  • Page 89: 30 520R, 520R2 and 520Re

    Watson-marlow 520dun ip66/nema 4x user manual 89 30 520r, 520r2 and 520re maintenance as part of regular cleaning and maintenance (and at least every three months), lubricate the pivot points, the follower rollers and the tube guide rollers with ultra lube (pa 1240), which is a non-toxic perfluoroet...

  • Page 90: Settings

    Watson-marlow 520dun ip66/nema 4x user manual 90 general guide to cleaning with solvents 31 520r, 520r2 and 520re rotor settings 520r, 520r2 and 520re pumpheads are factory-set to give optimum tube life with watson-marlow tubing and elements. Radial roller positions should not be adjusted in any cir...

  • Page 91: 32 Pumphead Spares

    Watson-marlow 520dun ip66/nema 4x user manual 91 32 pumphead spares parts may be ordered individually. 053.1011.100 520r 053.1011.2l0 520r2 053.1011.El0 520rel 053.1011.Em0 520rem 053.1011.Eh0 520reh 1 mna2050a (520r, 520r2) pumphead guard complete with tool-unlockable latch 2 mna2045a (520r, 520r2)...

  • Page 92: 33 Flow Rates

    Watson-marlow 520dun ip66/nema 4x user manual 92 33 flow rates pumping conditions for precise and repeatable performance it is important to determine flow rates under operating conditions for each new piece of tubing. When rotating counter-clockwise, 520r, 520r2 and 520re pumpheads’ flow rates are d...

  • Page 93

    Watson-marlow 520dun ip66/nema 4x user manual 93 520re performance figures for the 520rel and 520rem have been recorded against 2bar peak pressure and 4bar peak pressure respectively. Performance figures for the 520reh have been recorded against 7bar constant pressure. Although the 520rel is rated t...

  • Page 94

    Watson-marlow 520dun ip66/nema 4x user manual 94 520r fluorel (ml/min) speed range 1.6mm 3.2mm 4.8mm 6.4mm 8.0mm 520dun/r, 520dun/r2 0.1- 220rpm 0.03- 70 0.13- 280 0.29- 630 0.51- 1100 0.80- 1800 520r fluorel (usgph) speed range 1.6mm 3.2mm 4.8mm 6.4mm 8.0mm 520dun/r, 520dun/r2 0.1- 220rpm 0.0005- 1...

  • Page 95

    Elements watson-marlow 520dun ip66/nema 4x user manual 95 520rel neoprene, sta-pure, chem-sure, pumpsil (ml/min) 520rel marprene / bioprene tl (ml/min) speed range 3.2mm 6.4mm 9.6mm 3.2mm 6.4mm 9.6mm 520dun/rel 0.1- 220rpm 0.18- 390 0.70- 1500 1.6- 3500 0.17- 370 0.67- 1500 1.5- 3300 520rem sta-pure...

  • Page 96

    Watson-marlow 520dun ip66/nema 4x user manual 96 performance curves marprene continuous tubing, 1.6mm wall, 200rpm, clockwise rotation marprene continuous tubing, 1.6mm wall, 200rpm, counter-clockwise rotation.

  • Page 97

    Watson-marlow 520dun ip66/nema 4x user manual 97 marprene continuous tubing, 2.4mm wall, 200rpm, clockwise rotation marprene continuous tubing, 2.4mm wall, 200rpm, counter-clockwise rotation.

  • Page 98

    Watson-marlow 520dun ip66/nema 4x user manual 98 marprene tl element, 0-2 bar (0-30psi), 200rpm, counter-clockwise rotation sta-pure element, 0-2 bar (0-30psi), 200rpm, counter-clockwise rotation marprene tm element, 2-4 bar (30-60psi), 200rpm, counter-clockwise rotation sta-pure element, 2-4 bar (3...

  • Page 99

    Watson-marlow 520dun ip66/nema 4x user manual 99 marprene th element, 4-7 bar (60-100psi), 200rpm, counter-clockwise rotation.

  • Page 100

    Watson-marlow 520dun ip66/nema 4x user manual 100 34 tubing and element part numbers 1.6mm wall tubing for 520r pumpheads mm inch # marprene bioprene chem-sure 0.5 1 / 50 112 902.0005.016 903.0005.016 0.8 1 / 32 13 902.0008.016 903.0008.016 1.6 1 / 16 14 902.0016.016 903.0016.016 965.0016.016 3.2 1 ...

  • Page 101

    Watson-marlow 520dun ip66/nema 4x user manual 101 2.4mm wall tubing for 520r2 pumpheads mm inch # marprene bioprene pumpsil 0.5 1 / 50 913.A005.024 0.8 1 / 32 913.A008.024 1.6 1 / 16 119 902.0016.024 903.0016.024 913.A016.024 3.2 1 / 8 120 902.0032.024 903.0032.024 913.A032.024 4.8 3 / 16 15 902.004...

  • Page 102

    Watson-marlow 520dun ip66/nema 4x user manual 102 2.4mm wall elements for 520re pumpheads 0-2 bar (0-30 psi) pressure rated elements industrial mm inch # marprene tl pumpsil neoprene chem-sure 3.2 1 / 8 16 902.0032.Pfq 913.A032.Pfq 920.0032.Pfq 965.0032.Pfq 6.4 1 / 4 17 902.0064.Pfq 913.A064.Pfq 920...

  • Page 103

    Watson-marlow 520dun ip66/nema 4x user manual 103 35 520 series pumping accessories accessory description part code pump compatibility 520anc network cable, rs232, with 9-pin d-connectors 059.3121.000 520du, 520di 520anx network extension cable with 9-pin d-connectors 059.3122.000 520du, 520di 520an...

  • Page 104: 36 Trademarks

    Watson-marlow 520dun ip66/nema 4x user manual 104 36 trademarks watson-marlow, bioprene, pumpsil, loadsure and marprene are trademarks of watson-marlow limited. Fluorel is a trademark of 3m. Sta-pure and chem-sure are trademarks of w.L.Gore and associates. 37 warning not to use pumps in patient-conn...

  • Page 105

    Watson-marlow 520dun ip66/nema 4x user manual 105 39 decontamination certificate in compliance with the uk health and safety at work act and the control of substances hazardous to health regulations, you are required to declare the sub- stances which have been in contact with product(s) you return t...