Watson-Marlow 604S/R Installation And Operating Istructions

Manual is about: IP55 ingress protection, variable speed high-flow pump

Summary of 604S/R

  • Page 1

    Publication pb 0175 issue 2 ip55 ingress protection, variable speed high-flow pump installation and operating instruction drive/s: issue 4 eprom: n/a pumphead/s: 603r issue 1 contents declarations .................................................... Page 2 604s/r.

  • Page 2

    Page 2 safety .................................................... Page 3 information for returning pumps ....................................................Page 3 two year warranty .................................................... Page 3 recommended operating procedures ...........................

  • Page 3

    Page 3 safety in the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have read and understood this manual, and considered any hazard involved. Any person who is involved in the installation or maintenance of this equipmen...

  • Page 4

    Page 4 recommended operating procedures do keep delivery and suction lines as short as possible. Do use the minimum number of bends in rigid pipe runs. If there must be a bend, use a swept bend and not a tight elbow. Do run at a slow speed when pumping viscous fluids. 9.6 or 12.7mm bore tube with a ...

  • Page 5

    Page 5 part 1: drive siting to ensure correct lubrication of the gear box it is important to run the pump only while its feet are standing on a horizontal surface. It should be situated where there is free air to circulate around the pump and where the tubing is allowed to enter the tube clamps with...

  • Page 6

    Page 6 part 2: operation overview start the pump by turning the forward/off/reverse switch on the left hand side of the front panel to the required direction of rotation. The preferred direction of rotation is clockwise (with fluid entering at the bottom right of the pumphead and exiting at the top ...

  • Page 7

    Page 7 part 3: 603r pumphead installation the 604s drives are fitted with pumpheads which incorporate an electrical "safe-guard" isolation switch which will disable the drive when the pumphead is opened or removed. To fit the pumphead first remove the cover from the cased drive. Pass the pumphead gu...

  • Page 8

    Page 8 tube loading switch off the pump and isolate it from the mains supply before loading tubing. If the pump is not switched off before the pumphead guard is raised, a switch on the guard will cut off power to the motor. This switched guard is a safety back-up system and must not be used as the p...

  • Page 9

    Page 9 pumphead spares mr 0574t spindle - guide roller mr 0283m hinge moulding 5 required mr 0573t spindle - main roller mr 0601t collet mra0010a rotor assembly track assembly mr 0571t main roller, 2 required mr 0575t guide roller, 4 required mr 0572t follower roller, 2 required guard - no magnet sg...

  • Page 10

    Page 10 part 4: appendices specification nominal maximum rotor speed 165rpm speed control range 2 percent to 100 percent operating voltages/frequencies 100-240v 50/60hz single phase maximum power consumption 250va fuse rating type t (anti-surge) 5a operating temperature range 5c to 40c storage tempe...

  • Page 11

    Page 11 outline drawing.

  • Page 12

    Page 12 decontamination certificate watson-marlow limited health and safety declaration 1.0 this procedure is a legal requirement in the uk 3.0 either fax this form or send by first class post and must be used when returning pumps and to watson-marlow (or its distributor) to ensure equipment for ser...