Install the Control
7.
User Interface
Front
Base
Home
Button
ENTER
HomeButton
Returntothe
HomeScreen
Pressandholdfor3
secondstoaccessthe
programmingmenus.
Touchtogotothe
nextsetting
Touchtoquicklyenter
theViewmenu
Touchto
adjustsettings
Operation
Field
StatusField
Touchtodisplay
RunTime,
Outdoor&Slab
Temperature
Touchto
MeltorStop
Touchtoturnsystem
offwhileaway
8.
Critical Settings
Item Field
Description
APPLICATIon MoDE
Selectthecontrolapplicationmode.
PWM=HydronicPulseWidthModulation.
BOIL=Hydronicboilerheatssnowmelting
system.
MIX=Hydronicmixingvalveorinjection
pumpheatssnowmeltingsystem.
ELEC=Electricsnowmelt.
090=TandemSnow/IceDetection
Default=PWM
SnoW / ICE SEnSoR
SelectifaSnow/IceSensor090orSnow
Sensor095isinstalled.
Default=090
SLAB SEnSoR
SelectifaSlabSensor072isinstalledto
measuretheslabtemperature.
Default=ON
SLAB PRoTECTIon
Selectiftheslabshouldbeprotectedfromlarge
temperaturedifferentialstoavoidcrackingthe
concreteduetohightensilestress.
Default=ON
TheSystemMenuprovidessettingsonhowtoconfigureandoperatethemechanicalequipment.
Item Field
Description
oUTDooR/BoILER RETURn SEnSoR
SelectiftheOut/Bretwiringterminalis
connectedtoanoutdoorsensororaboiler
returnsensor.
Default=OUT
EConoMELT
EconoMeltallowstheusertomechanically
removesnowthenmanuallystartthesystem
tomeltthethinsnowlayerorice.
Default=OFF
tekmarnet
®
SySTEM PUMP
Selectifthesystempumplocatedonthe
tekmarNet
®
SystemControlshouldoperate
whenthesnowmeltzoneisheating.
Conditions:ApplicationModeissettoPWM,
BoilorMixandBoilerTypeissettoCTRL
(tN4control).
Default=ON
AUxILIARy RELAy
Selectiftheauxiliaryrelayshouldfunction
assystempumporasanalert.
Default=SYS
MAxIMUM MELT TIME
Selecttolimittheamountofmeltingrun
time.
Default=3.0days