Watts Premier B-RO5M-50 Installation, Operation And Maintanance Manual

Summary of B-RO5M-50

  • Page 1

    Page 1 installation, operation and maintenance manual refer to enclosed warranty for operating parameters to ensure proper use with your water supply. Watts premier, inc. 1725 w. Williams drive c-20 phoenix, az 85027 phone: 800-752-5582 www.Wattspremier.Com fax: 623-931-0191 save manual for future r...

  • Page 2

    Page 2 thank you for your purchase of a state of the art watts premier reverse osmosis (ro) water treatment system. Water quality concerns are quickly becoming more of a focus for the public. Lately you may have heard about contaminants in the drinking water, such as arsenic, chromium, cryptosporidi...

  • Page 3: Table of Contents

    Page 3 with proper installation and maintenance, this system will provide you with high quality water for years to come. All of watts premier’s water enhancement products are rigorously tested by independent laboratories for safety and reliability. If you have any questions or concerns, please conta...

  • Page 4: Operational Parameters

    Page 4 hardness: recommended hardness should not exceed 10 grains per gallon, or 170 ppm. System will operate with hardness over 10 grains but the membrane life will be shortened. (addition of a water softener may lengthen the membrane life.) 1 tank – white 1 module – white 1 parts bag – with a fina...

  • Page 5

    Page 5 make sure the surroundings of the sink are cooled before mounting the faucet to the sink after drilling. Remove all sharp edges. Step 3 step 4 determine desired location for the faucet on your sink and place a piece of masking tape on location where the hole is to be drilled. Mark the center ...

  • Page 6

    Page 6 gather and identify the faucet pieces. Watts premier (top mount) monitor faucet installation step 2 step 3 step 4 step 5 step 6 note: tubing connections the blue tube from the faucet should be connected to the clean water source, such as from the ro system, clean water storage tank, or from t...

  • Page 7

    Page 7 ag-ss with tds monitor faucet installation step 6 step 7 remove the stem nut and the tubing guide from the faucet. Make sure the soft rubber gasket remains, so it will be on top of the counter when installed. From above the sink, feed the tubing and faucet stem down through the 1¼ inch mounti...

  • Page 8

    Page 8 ag-ss with monitor faucet installation - part# 116061 step 6 step 7 gather and identify the faucet pieces. Remove faucet and small parts from plastic bag. Slip the gasket over the threaded stem to the faucet flange. From above the sink, feed the tubing and faucet stem down through the 1¼ inch ...

  • Page 9: Hot

    Page 9 adapta valve installation - part# 134007 turn off the cold water supply to the faucet by turning the angle stop valve completely off. Reverse osmosis module mounting step 13 determine best location for the ro module to be mounted to allow for future system maintenance. The parts bag has 2 sel...

  • Page 10

    Page 10 thread the plastic elbow (supplied in the parts bag) onto the stainless steel connection on the top of tank. Tighten using an adjustable wrench. Do not over tighten as plastic could crack. Step 17 step 18 wrap (7 to 12 turns) teflon tape clockwise around the male pipe threads (mpt) on the sta...

  • Page 11: Green Tube Connection

    Page 11 connect blue tube from tank port on ro module to the tank position tank in desired location. Stand it upright or lay it on its side (using the black plastic stand). Measure the blue tube from the ro module port marked tank over to the tank and cut it to desired length. Insert the blue 3/8” t...

  • Page 12

    Page 12 3/8” black tube connection from faucet measure the black tube from faucet to the black drain saddle and make a straight cut through tube. Remove black plastic nut from drain saddle. Slip black tube through black nut. Insert black tube into the opening in the drain saddle and hand tighten the...

  • Page 13: Final Filter Installation

    Page 13 thread the larger (3/8”) white plastic connector into the other end of the final filter. Step 29 thread the smaller (1/4”) white plastic connector into the end of the final filter and tighten , (flow arrow on filter points to the 1/4” connector). Step 30 the final filter and 2 white plastic conn...

  • Page 14: Start Up Instructions

    Page 14 start up instructions register warranty by mail, phone, or internet. Watts premier uses this information only to provide a filter change reminder service. Pre-filters should be changed every six months. You may register your warranty via our website at www.Wattspremier.Com or call 1-800-752- 5...

  • Page 15: 6 Month System Maintenance

    Page 15 √ one 10” sediment filter (part no. 104017) √ bucket to catch water from filter housings. √ two 10” carbon filters (part no. 101009) clean all filter housings (bowls) with a mild soap solution and rinse with water. Check o-rings and lubricate with water soluble lubricant. Ky jelly ® , canola oil...

  • Page 16: Membrane Replacement

    Page 16 membrane replacement membranes have a life expectancy of between 2 and 5 years, depending on the incoming water conditions and the amount of use of the ro system. Normally, a membrane would be replaced during a semiannual or annual filter change. However, if at any time you notice a reduction...

  • Page 17

    Page 17 pull firmly on the membrane to remove from the housing and discard. Unwrap new membrane and lubricate the o-rings with water soluble lubrication such as ky jelly ® before inserting into housing. Insert end with the two black o-rings into the cap. Twist the membrane as you push firmly into the ...

  • Page 18

    Page 18 check air pressure when tank is empty of water! Check air pressure in the tank when you notice a decrease in available water from the ro system. It is recommended that you drain the tank of water, and then pump up the ro tank in order to ensure all water is out of the tank. Air can be added ...

  • Page 19: Trouble Shooting

    Page 19 trouble shooting problem cause solution 1. Low/slow production low water pressure assure a minimum of 40 psi incoming water pressure. Premier sells a booster pump if home water pressure is low. Maker sure water supply is turned on and adapta valve is all the way open crimps in tubing check t...

  • Page 20

    Page 20 arsenic fact sheet arsenic (as) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results ...

  • Page 21: California Certification

    Page 21 california certification state of california department of health services water treatment device certificate number 1452 date issued: october 17, 2005 trademark/model designation 00 - watts premier deluxe plus watts premier ultra 5 watts premier pur-tek watts premier watts 25 watts premier r...

  • Page 22: Performance Data Sheet

    Page 22 recommended replacement parts and change intervals: note: depending on incoming feed water conditions replacement time frame may vary. Description change time frame sediment pre-filter: #5m-10 6 months carbon pre-filter: #gac-410-56/#5mcb 6 months final carbon filter #1m-6/#1m-10 12 months r.O....

  • Page 23: Performance Data Sheet

    Page 23 recommended replacement parts and change intervals: depending on incoming feed water conditions replacement time frame may vary. Change time description 6 months: sediment pre-filter; carbon pre-filters 12 months final carbon filter 2 to 5 years r.O. Membrane this system has been tested accordi...

  • Page 24

    Page 24 1 1 100014 gac-il-10-1-4 f-premier 2 1 100037 gac-kdf 802 10 inch 3 2 101009 carbon block-10 inch-5m-ctg-watts 4 1 104017 sed-spun-10 inch-5m-ctg 5 3 113018 bowl-manifold 6 1 113035 membrane vessel - manifold 7 6 113041 o-ring-bowl-manifold-341 8 1 113045 o-ring-vessel-manifold-233 9 1 11602...

  • Page 25

    Page 25 watts premier has other fine water filtration products and accessories to enhance your water and to compliment your existing ro system. Listed on the next several pages are only a few of the items we offer. Visit our website at www.Wattspremier.Com or call our customer service representatives ...

  • Page 26

    Page 26 water pressure gauge this gauge mounts onto your outside hose connection to accurately show your home’s water pressure up to 300 psi. A red needle shows peak overnight pres- sure, which may exceed readings during the day. High pressure readings may indicate the need for a pressure regulator ...

  • Page 27

    Page 27 removing chlorine from your shower deluxe shower handle with built in filter replacement filters 2pk 5-way massaging spray 72” reinforced hose high strength bracket triple plated finish reversible filter cartridge (model hhc) cartridge life rating: 3 months part no. 107090 white part no. 1070...

  • Page 28: 4 Ways to Register

    Page 28 4 ways to register 1. Online at www.Wattspremier.Com 2. Call in your information 1-800-752-5582 3. Fax in your information 623-931-0191 first name:_________________________ last name:____________________________ address: ________________________________________ city: ____________________ sta...

  • Page 29: Warranty Registration

    Page 29 warranty registration please fill out and keep for your records insert into envelope and return to watts premier first name:_________________________ last name:____________________________ address: ________________________________________ city: ____________________ state: ___________________...

  • Page 30: Service Record

    Page 30 service record date of purchase:__________ date of install:___________ installed by:__________________ serial no. _____________________ date 1st stage sediment (6 months) 2 nd stage carbon (6 months) 3rd stage carbon (6 months) final filter carbon (1 year) tfm membrane (2-5 years) notes:.

  • Page 31

    Page 31.

  • Page 32: Limited Warranty

    Page 32 limited warranty what your warranty covers: if any part of your watts premier reverse osmosis system is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 3 year of original retail purchase,...