Watts Premier RO-PURE Plus Installation, Operation And Maintenance Manual

Manual is about: Water Supply

Summary of RO-PURE Plus

  • Page 1

    Page 1 installation, operation and maintenance manual refer to enclosed warranty for operating parameters to ensure proper use with your water supply. Save manual for future reference warning please read carefully before proceeding with installation. Your failure to follow any attached instructions ...

  • Page 2

    Page 2 thank you for your purchase of a state of the art premier reverse osmosis (ro) water treatment system. Water quality concerns are becoming more of a focus for the public. You may have heard about contaminants in the drinking water such as arsenic, chromium, cryptosporidium or giardia. There m...

  • Page 3: Table of Contents

    Page 3 ** before installation, please take a moment to fill out the warranty card on page 23. Table of contents operational parameters ................................................................................................................... 4 contents of reverse osmosis system ...............

  • Page 4: Operational Parameters

    Page 4 installation must comply with state and local plumbing regulations. Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed using the cold water supply only. Tools recommended fo...

  • Page 5

    Page 5 part no. Description 1 115304 filter module 2 134003 automatic shut off valve 3 119007 storage tank - 3 gallons 4 560080 adapt-a-valve kit 5 420102 faucet - tmt - brushed nickel 6 134018 tank valve - 1/4f x 1/4” qc 7 164056 drain saddle - 3/8” qc - kit 8 119028 tank stand 9 142000 1/4” green ...

  • Page 6

    Page 6 after drilling, remove all sharp edges and make sure the surroundings of the sink are cooled before mounting the faucet. Step 3 step 4 determine desired location for the ro faucet on your sink and place a piece of masking tape over where the hole is to be drilled. Mark the center of the hole ...

  • Page 7: Assemble Faucet (Figure C)

    Page 7 connect tubes to the ro faucet (figure a) this ro faucet is equipped with quick connect fittings for easy tube installation. 1. In the parts bag, locate one 1/4” red tube, one 1/4” blue tube and one 3/8” black tube. 2. Connect the straight end of the 1/4”-blue tube to the corresponding fittin...

  • Page 8: Adapt-A-Valve Installation

    Page 8 turn off the cold water supply to the faucet by turning the angle stop valve completely off. Open cold water sink faucet to relieve pressure. Step 5 step 6 choosing the configuration that fits your plumbing, attach the adapt-a-valve as illustrated in the four photos above. Adapt-a-valve insta...

  • Page 9: Drain Saddle Installation

    Page 9 drain saddle fits standard 1 ¼” – 1 ½” drain pipes drain saddle installation step 7 step 8 step 9 the drain saddle must be installed at least 1 ½” above the nut of the p-trap elbow or cross bar from the garbage disposal to insure proper drainage. Using the 1/4” drill bit, drill into the drain...

  • Page 10: Rear View of Ro-Pure System

    Page 10 red tube connection (from faucet to the ro module) locate the 1/4” red tube attached to the ro faucet. Insert the end of the red tube with the 90* bend into the open 1/4” quick connect fitting on the back side of the ro-pure head behind the membrane head making sure the tube is pushed in all...

  • Page 11: Tank Ball Valve Installation

    Page 11 blue tube connection (from the tank to shut off valve) position tank in desired location. Stand it upright or lay it on its side (using the black plastic stand). Measure the blue tube (marked “tank”) from the ro module to the tank and cut it to length leaving a straight, square edge. Insert ...

  • Page 12: Startup Instructions

    Page 12 startup instructions if you have connected your ro system to a refrigerator / ice maker, make sure the ice maker is off (do not allow water to flow to the ice maker) until flushing (step 4) is complete and the tank has been allowed to fill completely. Connection from the ro to the ice maker ...

  • Page 13: Annual Maintenance

    Page 13 place a towel under the ro module to catch any excess water that may drip out from the filters during the changeover. Step 1 your ro module is equipped with valve heads which will automatically turn off the water supply to each filter when the filter is released, thus you do not need to turn...

  • Page 14: Annual Sanitization

    Page 14 annual sanitization notice do not change your post-carbon filter until the sanitization has been completed. The pre-filters and membrane can be changed before the sanitization step 1: turn off the water supply to your ro system at the adapt-a- valve and open the ro faucet to drain the storag...

  • Page 15: To Restart System:

    Page 15 check air pressure in the tank notice check air pressure only when tank is empty of water! Check air pressure in the storage tank when you notice a decrease in available water from the ro sys - tem. Air can be added with a bicycle pump using the schrader valve that is located on the lower si...

  • Page 16: Trouble Shooting

    Page 16 trouble shooting problem cause solution 1. Low/slow production low water pressure assure a minimum of 40 psi incoming water pressure. Premier sells a booster pump if home water pressure is low. Make sure water supply is turned on and feed water valve is all the way open. Crimps in tubing che...

  • Page 17

    Page 17 watts premier 8716 w ludlow drive suite #1 peoria, az 85381 ro-pure plus system conforms to nsf standard 58 for specific claims. Recommended replacement parts and change intervals: note: depending on incoming feed water conditions replacement time frame may vary. Description change time fram...

  • Page 18

    Page 18 substance percent reduction influent challenge concentration (mg/l unless noted) maximum permissible product water concentration alachlor >98% 0.05 0.001 atrazine >97% 0.1 0.003 benzene >99% 0.081 0.001 bromodichloromethane (tthm) >99.8% 0.300 +/- 0.30 0.015 bromoform (tthm) >99.8% 0.300 +/-...

  • Page 19: Arsenic Fact Sheet

    Page 19 arsenic (as) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results from your water uti...

  • Page 20

    Page 20 this page intentionally left blank.

  • Page 21: Service Record

    Page 21 service record date of purchase:__________ date of install:___________ installed by:_____________ notes: date sediment filter (6 months) membrane (2-5 years) carbon pre-filter (6 months) voc post-filter (12months) model number:__________ serial number:___________.

  • Page 22: Limited Warranty

    Page 22 limited warranty what your warranty covers: if any part of your reverse osmosis system is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, watts premie...