Gather and identify the faucet pieces.
Remove faucet base & faucet spout from their respective
plastic bags. From above the sink, feed the faucet tubing &
toggle bolt down through the 1¼” mounting hole in the sink.
Ensure that the soft rubber gasket is uniformly positioned in
between the base and the top of the sink.
Align the faucet base so that the handle is on the right side and
the base is sitting fl ush on the sink top. Turn the handle down
(towards you) to the “ON” position to reveal the tightening
screw (located where the spout will be inserted). Using a
phillips head screwdriver, turn the screw clockwise until the
toggle bolt secures the faucet base snug onto the sink top,
do not over torque toggle bolt (5lb.in. max)
Once the faucet base is securely fastened to the sink top,
insert the faucet spout into the faucet base until it is fully
seated. Turn the handle up (away from you) to the “OFF”
position.
Completion of faucet installation (tubing connections) will be
done later in this manual. Refer to the Black Tube Connection
(page 11), Red Tube Connection (page 12), and Blue Tube
Connection (page 12) sections of this manual.
Remove the faucet battery from the plastic bag. Locate the faucet battery compartment drawer on the base of the
faucet. Using a small screwdriver to pry on the notch at the compartment drawer face, slide the drawer out. Insert
the battery into the battery compartment drawer.
NOTE: The + side of the battery faces up. The compartment drawer will not slide in if the battery is installed
upside down.
Once the battery is in place, slide the battery compartment drawer back into the base until it is fl ush.
When the battery is fi rst installed, both the red and green lights will fl ash to indicate that both lights are functional.
Thereafter, it will fl ash green only when the faucet handle is turned to the “ON” position. When your system is ready to
be serviced (approximately six months) you will see the light fl ash red when the handle is turned to the “ON” position.
Refer to the Six Month Maintenance (page 13) section of this manual for fi lter replacement.
NOTE: If your water usage is high the red light may activate sooner than six months indicating the need for
fi lter replacement.
This faucet provides an electronic monitor that will tell you when it is time to replace the fi lters in your
water treatment device. The light indicator will be green for the life of the fi lter, turning red once the life
of the fi lter has been reached. This can occur after six months of use, or sooner for heavy water usage.
To reset the electronic monitor during replacement of fi lters, simply slide out the battery from the faucet
and reinsert. The battery life is expected to last one year, however, for heavy use the battery may need
to be replaced sooner. For replacement, look for battery number CR2354 (Watts p/n:116082) which is
available at your local battery store or contact Watts Premier at 800-752-7782. You can also order online
at www.wattspremier.com.
WATTS Premier Chrome Top Mount & Top Mount Monitored
Faucet Installation
Step 6
Step 7
Step 8
Step 9
Step 10
Faucet Battery Installation (For Monitored Faucets Only - P/N:116074)
Minimum
Maximum
Mounting Hole Size
1.00”
1.25”
Torque on Toggle Bolt
5lb.in. (max)
Watts Faucets
P/N: 116000 Chrome (Non-Monitored)
P/N: 116072 Brushed Nickel (Non-Monitored)
P/N: 116074 Chrome (Monitored)