Watts PWRO4ZRO Pure Water Installation, Operation And Maintenance Manual

Manual is about: Zero Waste Reverse Osmosis System

Summary of PWRO4ZRO Pure Water

  • Page 1

    Installation, operation and maintenance manual zero waste reverse osmosis system model pwro4zro iom-wq-pwro4zro table of contents pages operational parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 contents of reverse osmosis system . . . . . . . . . . . . . . . . . ...

  • Page 2

    2 introduction thank you for your purchase of a state of the art watts reverse osmosis (ro) water treatment system. Water quality concerns are becoming more of a focus for the public . You may have heard about contaminants in the drinking water, such as arsenic, chromium, cryptosporidium or giardia ...

  • Page 3

    3 operating temperatures maximum 100°f (37.8°c) minimum 40°f (4.4°c) operating pressure maximum 85psi (6.0 kg/cm2) minimum 40psi (2.80 kg/cm2) ph parameters maximum 11 minimum 2 iron maximum 0.2 ppm tds (total dissolved solids) turbidity operational parameters do not use with water that is microbiol...

  • Page 4

    4 how to use the quick-connect fittings on the ro module to make a connection, the tube is simply pushed into the fitting . Place a piece of tape 1 / 2 " from end of tube to indicate how far the tube should be inserted . The unique patented quick-connect locking system holds the tube firmly in place...

  • Page 5

    5 step 4 reverse osmosis module mounting step a – determine best location for the ro module to be mounted to allow for future system main- tenance . The parts bag has 2 self-tapping screws . Using an electric drill with a phillips bit, screw them into the cabinet wall 6" apart and 16" from the botto...

  • Page 6

    6 step 5 green tube connection step a – locate green tube attached to the ro module . Insert the open end of the green 1 ⁄ 4 " tube into the open 1 ⁄ 4 " quick-connect fitting on the adapt- a-valve™ making sure the tube is pushed in all the way to the tube stop . Step b – connect the green tube from...

  • Page 7

    7 start up instructions warning: to prevent the possibility of electrical shock, clean up any water on cabinet floor and dry all water from outside of ro unit. Step a– turn on the incoming cold and hot water at the angle stop valves by turning the knob on the adapt-a-valve™ coun- terclockwise . Chec...

  • Page 8

    8 step e – clean the filter housings (bowls) with a mild soap solution and rinse with water . Check o-rings and lubricate with water soluble lubricant. Ky jelly ® , canola oil or other water based lubricants may be used . Petroleum based lubricants (such as vaseline ® ) must not be used. Caution: be...

  • Page 9

    9 membrane replacement this reverse osmosis system contains a replaceable component (the ro membrane) which is critical to the efficiency of the system. Replacement of this reverse osmosis membrane should be with one of identical specifications as defined by watts to assure the same efficiency and c...

  • Page 10

    10 problem cause solution 1. Low/slow production excessive air pressure in tank relieve pressure at schrader valve on tank (set to 7psi with the tank empty) pump not operating wiring connection broken (plug 110 ac wall, plug back in at wall and/or reconnect the 24 vac wire harness connectors) replac...

  • Page 11

    11 parts list cold-water shut-off valve carbon pre-filter sediment pre-filter tee fitting membrane housing storage tank 1/4” green tube feed water carbon post-filter faucet permeate 1/4” black tube - brine flow restrictor flow adapt-a-valve 28 1 to kitchen sink 17 25 24 25 24 26 12 15 22 11 9 3 3 27...

  • Page 12

    12 arsenic facts arsenic (as) is a naturally occurring contaminant found in many ground waters . Arsenic in water has no color, taste or odor . It must be measured by an arsenic test kit or lab test . Public water utilities must have their water tested for arsenic . You can obtain the results from y...

  • Page 13

    13 date of purchase date of install installed by date 1st stage sediment (6 months) 2nd stage carbon (6 months) 3rd stage carbon (6 months) final filter carbon (1 year) tfm membrane (2 – 5 years) notes: service record.

  • Page 14

    14.

  • Page 15

    15.

  • Page 16

    Iom-wq-pwro4zro 1225 edp# 2915899 © 2012 watts usa: tel. (800) 224-1299 • www .Watts .Com canada: tel. (888) 208-8927 • www .Watts .Ca a watts water technologies company limited warranty: certain watts pure water products come with a limited warranty from watts regulator co. Other products may have ...