Watts PWROKC4 Installation, Operation And Maintenance Manual

Manual is about: Reverse Osmosis System

Summary of PWROKC4

  • Page 1

    Installation, operation and maintenance manual kwik-change™ reverse osmosis system model pwrokc4 iom-wq-pwrokc4 important please read the entire manual before proceeding with the installation and startup. Your failure to follow any attached instructions or operating parameters may lead to the produc...

  • Page 2

    2 introduction thank you for your purchase of a state of the art watts reverse osmosis (ro) water treatment system. Water quality concerns are becoming more of a focus for the public . You may have heard about contaminants in the drinking water, such as arsenic, chromium, cryptosporidium or giardia ...

  • Page 3

    3 operating temperatures maximum 100°f (38°c) minimum 40°f (4°c) operating pressure maximum 85psi (6.0 kg/cm2) minimum 40psi (2.80 kg/cm2) ph parameters maximum 11 minimum 2 iron maximum 0.2 ppm tds (total dissolved solids) turbidity operational parameters do not use with water that is microbiologic...

  • Page 4

    4 how to use the quick-connect fittings on the ro module to make a connection, the tube is simply pushed into the fitting . Place a piece of tape 1 / 2 " from end of tube to indicate how far the tube should be inserted . The unique watts quick-connect locking system holds the tube firmly in place wi...

  • Page 5

    5 step 2 watts chrome top mount faucet installation gather and identify the faucet pieces. Step a - remove faucet base and faucet spout from their respective plastic bags . From above the sink, feed the faucet tubing and toggle bolt down through the 1¼" mounting hole in the sink. Ensure that the sof...

  • Page 6

    6 step 6 reverse osmosis module mounting step a – determine best location for the ro module to be mounted to allow for future system main- tenance . The parts bag has 2 self-tapping screws . Using an electric drill with a phillips bit, screw them into the cabinet wall 6" apart and 16" from the botto...

  • Page 7

    7 step a – use supplied teflon ® tape to wrap the tank nipple with 4 to 8 layers of teflon tape . Step b – install supplied ball valve elbow fitting . (do not over tighten) tank ball valve installation step 9 step a – position tank in desired loca- tion . Stand it upright or lay it on its side (usin...

  • Page 8

    8 order filter by calling watts at 1-800-224-1299 item needed: edp# 7100116 includes: • (1) sediment filter • (1) carbon block filter this reverse osmosis system contains a replaceable compo- nent (the ro membrane) which is critical to the efficiency of the system. Replacement of this reverse osmosi...

  • Page 9

    9 membrane replacement this reverse osmosis system contains a replaceable component (the ro membrane) which is critical to the efficiency of the system. Replacement of this reverse osmosis membrane should be with one of identical specifications as defined by watts to assure the same efficiency and c...

  • Page 10

    10 problem cause solution 1. Low/slow production low water pressure assure a minimum of 40psi incoming water pressure. Watts sells a booster pump if home water pressure is low. Make sure water supply is turned on and adapt-a-valve™ is all the way open. Crimps in tubing check tubing and straighten or...

  • Page 11

    11 parts list the reverse osmosis system contains a replaceable treatment component, critical for the effective reduction of total dissolved solids and the product water shall be tested periodically to verify that the system is performing properly shut-off valve storage tank main water supply shut-o...

  • Page 12

    Iom-wq-pwrokc4 1225 edp# 2915874 © 2012 watts usa: tel. (800) 224-1299 • www .Watts .Com canada: tel. (888) 208-8927 • www .Watts .Ca a watts water technologies company limited warranty: certain watts pure water products come with a limited warranty from watts regulator co. Other products may have n...