  • Page 1

    Specifications voltage: ew-200-120, ew-205-120 ............................................. 120vac, 60hz ew-200-277, ew-205-277 ............................................. 277vac, 60hz mountable locations ......................................Wall, ceiling or under eaves operating temperature.......

  • Page 2

    1 box contents • one (1) ew-200-120, ew-205-120, ew-200-277 or ew-205-277 • accessory bag: cover plate for 4" round outdoor junction box, with two cover plate attachment hole plugs, cover plate gasket, cover plate screws & screw covers (4 ea), lens mask, wire nuts (3) • installation instructions con...

  • Page 3: Unit Description

    Unit description the ew sensors are outdoor passive infrared (pir) motion sensors rated for wet conditions. They are preassembled with a junction box cover and are ready to install to standard round outdoor junction boxes. The ew sensors utilize advanced pir technology and a superior lens design to ...

  • Page 4: Motion Sensor Placement

    Motion sensor placement careful consideration must be given to sensor placement. Pir sensors detect the difference between infrared energy in motion and the background space. To be detected, a person or vehicle must be within the sensor’s coverage pattern and have an unobstructed view of the sensor....

  • Page 5: Yes

    Mounting and sensor positioning guidelines warning: lamp bulb must be 1/2 inch or more from sensor housing 4 mount to flat, stable, vibration-free surface avoid runoff; sheltered locations preferred aim motion sensor downward to limit sensing mount motion sensor level do not mount by vents or above ...

  • Page 6: Wiring And Installation

    Wiring and installation caution turn power off at the circuit breaker before installing sensor . Sensor must be installed by qualified personnel only . 4" round outdoor junction-box cover plate to controlled loads check our web site for faqs: www .Wattstopper .Com 5 red black white gasket important!...

  • Page 7

    Wiring and installation (continued) orange(common) isolated relay green (normally closed) yellow (normally open) en multiple sensor/load wiring neutral red (load) black black white white white white white black red (load) black black switch (optional) line load load sensor sensor wire the sensor as ...

  • Page 8: Testing After Installation

    Check our web site for faqs: www .Wattstopper .Com 7 testing after installation to facilitate coverage testing, the factory setting for time delay is 12 seconds, and the light level is at maximum. If you want to test a sensor for intended detection or operation: 1. Make sure that the time delay is s...

  • Page 9: Making Changes

    Call 1(800) 879-8585 or 1(972)578-1699 for technical support 8 making changes if you want the lights to turn on/high sooner—turn the light level dial toward the sun icon, as desired; this raises the light level setting. (remember, the sensor must detect motion for lights to turn on.) • the lights tu...

  • Page 10: Security Override

    Check our web site for faqs: www .Wattstopper .Com 9 security override the ew sensors have an override-on feature which allows lights to be turned on for the set time delay period. • if there is an installed switch—turning the switch off then on, turns the lights on. If no motion is detected by the ...

  • Page 11: Warranty Information

    Warranty information wattstopper warranties its products to be free of defects in materials and workmanship for a period of five years. There are no obligations or liabilities on the part of wattstopper for consequential damages arising out of or in connection with the use or performance of this pro...

  • Page 12

    2800 de la cruz boulevard, santa clara, ca 95050, usa technical support: 800.879.8585 www.Wattstopper.Com 00335r4 09/2014 please recycle.