Wavecom GX64 Application Note

Manual is about: power Management

Summary of GX64

  • Page 1

    Page: 1/18 gx64 application note using optitrace this document is the sole and exclusive property of wavecom. Not to be distributed or divulged without prior written agreement. Ce document est la propriété exclusive de wavecom. Il ne peut être communiqué ou divulgué à des tiers sans son autorisation...

  • Page 2

    Trademarks ®, wavecom ® , wismo ® , open at ® , wireless cpu ® , wireless microprocessor ® and certain other trademarks and logos appearing on this document, are filed or registered trademarks of wavecom s.A. In france or in other countries. All other company and/or product names mentioned may be fi...

  • Page 3

    Table of contents 1 general................................................................................................. 5 1.1 scope.................................................................................................................... 5 1.2 abbreviations and terms ....................

  • Page 4

    5.2 firmware upgrade ............................................................................................ 15 5.3 hardware platform......................................................................................... 15 5.4 problem description ................................................

  • Page 5

    1 general 1.1 scope this application note describes how to use the optitrace tool used to capture debug logging information from the gr64 or gs64. This document is meant to be used in addition to the integrators manual and the at command manual for the gr/gs64 wireless cpu. 1.2 abbreviations and ter...

  • Page 6

    2 optitrace 2.1 overview with the next generation gx64 wireless cpus a new set of tools are required when debugging. The platform has the ability to log debug information from all subsystems such as sim, gsm layer 3, sms, csd, etc using the optitrace application. If a customer has problems with the ...

  • Page 7

    In this area of the extranet you can not only download the latest version of the optitrace application but also the software updater for the latest version of firmware. In order to run optitrace you must have one additional file, the trdata.Xml file which debug trace information. This xml file must ...

  • Page 8

    3 hardware 3.1 overview the gr64 and the gs64 send all debug information out via uart2. Wavecom recommends that customers design their pcbs to allow the second uart to be populated during the design and development phase so that debug information may be retrieved when required. Also, debug informati...

  • Page 9

    4 running optitrace 4.1 overview this section will describe how to setup and run optitrace after it has been installed. 4.2 trdata.Xml for each build of software that is loaded onto the module a file called trdata.Xml is created. The purpose of this file is to tell optitrace what traces have been ac...

  • Page 10

    When the module is turned on and you are able to see logging data running through the window, the two check sums, trace table crc and mobile crc should match, if they do not then the trdata.Xml file does not correspond with the build of software that is on the module.You can tell what the value of t...

  • Page 11

    Currently pointing to the correct trdata.Xml file. Currently pointing to the wrong trdata.Xml file. 4.3 project files when optitrace is run the first window that will be presented forces you to select a trace project file. Essentially this is a file that holds filter sets to set which debug informat...

  • Page 12

    Attached to this document is a project file that is useful as a starting point for tracking down a problem. This project file contains a filter called “at_ea_ip_allerrorswarnings” because it has all errors and warnings in the system turned on. Therefore, when reporting a problem it will help wavecom...

  • Page 13

    4.5 tcp/ip in addition to printing the out debug print statements, the optitrace tool has the ability to output a pcap file when you are doing ip transfers. If you are having problems with sending or receiving tcp/ip traffic then reading the pcap file from the module will tell you what data the modu...

  • Page 14

    4.6 embedded applications optitrace is also used to enable debugging of the embedded applications if you are using it. To enable the prtf traces to be received by optitrace the following needs to be set in the filters. Gs – gltracehigh it is recommended that the following is also set as it gives an ...

  • Page 15

    5 reporting an issue when reporting an issue with the gr64 or gs64 firmware there are a lot of items that wavecom support needs to know about to help us resolve your issue as quickly as possible. If these information items can be included in the initial trouble report it will cut down on the amount ...

  • Page 16

    5.6 copy of script if you are using embedded apps please include a copy of the script you were running when the problem occurred. If the problem happened with at commands please send a listing of the at commands entered and their response. If the scripts hold proprietary information then please prov...

  • Page 17

    6 references 6.1 optitrace optitrace includes a users manual that is installed with the application. 6.2 at commands at command manual application note for socket at commands 6.3 integrators manual integrators manual holds information on memory limitations of embedded applications scripts. 6.4 tools...

  • Page 18

    Page: 18/18 gx64 application note using optitrace this document is the sole and exclusive property of wavecom. Not to be distributed or divulged without prior written agreement. Ce document est la propriété exclusive de wavecom. Il ne peut être communiqué ou divulgué à des tiers sans son autorisatio...