Wayne WSM3300 Operating Instructions & Parts Manual

Manual is about: 12 Volt Advanced Notification System

Summary of WSM3300

  • Page 1

    Quick start instructions wsm3300 for parts, product & service information visit www.Waynepumps.Com 12 volt advanced notification system operating instructions & parts manual read, understand and follow all instructions in this manual - do not discard. Failure to follow these instructions could resul...

  • Page 2: 12 Volt Advanced

    Wsm3300 www.Waynepumps.Com reminder: keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. Read, understand and follow all instructions in this manual - do not discard. Failure to follow these instructions could result in property damage, bodil...

  • Page 3

    Transformer features • when plugged into 120vac, the transformer automatically provides power to the battery charging circuitry. • the transformer can be left connected to the wall outlet indefinitely. • the transformer is designed for the system only, do not use for any other purpose. 3 operating i...

  • Page 4

    4 wsm3300 method 2 - see figure 2 if a separate, dedicated discharge is not possible as in method 1, the back-up dc pump can be tied into the ac-operated pump’s discharge pipe by installing a “y” or "t" connector. Two check valves will be required. 1. Locate the back-up dc pump on a solid, level sur...

  • Page 5

    5 * phone line installation phone system information sharing the phone jack: the 12 volt advanced notification system and your existing phone/fax can share the same wall jack. A standard phone jack splitter also known as a line splitter (not provided) can be purchased at your local hardware store. I...

  • Page 6

    Critical step: it is recommended that a person at the call-to location confirms receiving the test phone call. Validate all calls before concluding that the system setup is finished. Entering and changing phone numbers when programming phone numbers into the system, enter each phone number into the ...

  • Page 7

    The system tallies and remembers the number of rings. 2. On your second call within “3” minutes, let the phone ring until the system answers. The system will answer first because it remembered the first “3” rings, and then answers with an audible system status. If done properly, the answering machin...

  • Page 8

    8 operating instructions 1. To test the back-up pump, unplug the main pump and transformer and fill sump with water until the water lifts the bottom float therefore activating the back-up pump. Repeat this process two times to be sure pump is operating normally. 2. If pump operates normally, plug th...

  • Page 9

    Troubleshooting chart message possible cause(s) corrective action back-up pump pump won't run 1. Connections not secure 2. Low or defective battery 3. Float switch stuck 4. Defective or blown fuse 1. Check all connections 2. Check battery and replace if low or defective 3. Make sure nothing is inter...

  • Page 10: For Replacement Parts Or

    For replacement parts or technical assistance, call 1-800-237-0987 please provide following information: - model number - serial number (if any) - part description and number as shown in parts list address parts correspondence to: wayne water systems 101 production drive harrison, oh 45030 u.S.A. Re...

  • Page 11

    11 operating instructions and parts manual wsm3300 quick reference cut-a-way card call your system to check system status: (no answering machine or digital voice mail service) 1. Make a phone call to the system (phone number at alarm location). 2. Wait for the system to answer (either five (5) or te...

  • Page 12: Système De Notification

    Instructions de dÉmarrage rapide wsm3300 pour des renseignements sur les pièces, les produits et l’entretien, visiter www.Waynepumps.Com système de notification préalable de 12 volts mode d’emploi et liste des piÈces dÉtachÉes © 2012, wayne/scott fetzer company. Étape 1 : vÉrification du contenu de ...