Wealtec ELITE 200 Service & Operation & Instruction Manual

Summary of ELITE 200

  • Page 1

    Wealtec corp. Elite 200 power supply service & operation & instruction manual version 2.0 item # 0 2012 http://www.Wealtec.Com e-mail : support@wealtec.Com.

  • Page 2

    Packing list x 1 main body x 1 power cable x 1 manual x 1 warranty card wealtec corp. 1885 meadowvale way, sparks, nv 89431, usa tel: +1-775-351-2066 fax: +1-775-351-2077 http://www.Wealtec.Com e-mail: support@wealtec.Com.

  • Page 3

    Index a. Important notice -------------------------------------------------------------------------------------------- 2 a-1. Warranty a-2. Technical and service contact a-3. Safety notice a-3-1. Certification a-3-2. Safety information b. Introduction ------------------------------------------------...

  • Page 4

    A. Important notice the instrument is designed for laboratory use only. Before setting up and operating elite 200 power supply, please carefully read these instructions to get familiarized with installation and operation process. Instructions should be read by well-trained individuals or by technica...

  • Page 5

    4. Damage caused by disaster. 5. Damage caused by any improper solvents or samples a-2. Technical and service contact most of the operation details are described in the instruction manual and operator can find appropriate solutions according to these instructions. For any other technical/ service qu...

  • Page 6

    A-3-2. Safety information basic safety precautions must be observed when operating the centrifuge in order to avoid hazards of electrical shock or possible physical injuries. Elite 200 power supply, is not to be used in class 1, division 1, group c hazardous location defined by the national fire pro...

  • Page 7

    B. Introduction elite 200 power supply is a settable power supplies with excellent quality. It is perfect for submerged horizontal, mini vertical gel electrophoresis and electro-blotting applications. The output of elite 200 power supply is controlled by timer and constant current/voltage, 4-set of ...

  • Page 8

    B-1. Specifications outputs: voltage 5-200vdc adjustable in 1v steps current 0.01-2.00adc adjustable in 0.01a step power 200w max. Input power 120/230, 50-60hz output terminals 4 set in parallel timer control 1-999 minutes display 3 digit 7 seg led panel control touch panel status alarm yes operatio...

  • Page 9

    B-2. Product descriptions the front and rear panel keys are used to set up and run the elite 200 power supply. A beep sound will alarm to inform user when front panel key been pressed. A long beep sound will alarm after the run is complete or if an error occurs. This beep sound will continue to alar...

  • Page 10

    8.

  • Page 11

    C. Installation 1. Carefully take out elite 200 power supply from the package box and place it at a stable, suitable place. 2. Connect power cable to correct power source and press the power switch to check elite 200 power supply is working properly. D. Operation instruction: step action description...

  • Page 12

    6 if programming a timed run, press mode to display time and enter the minuets to be run. Time is in minutes and the maximum is 999 minutes. If running in time mode a power failure detects (pfd) special function can be activated. 7 set pfd function (optional) when pfd function is activated and a pow...

  • Page 13

    8 press run start the run. During a run, you can view the run conditions just press the mode key. You also can change the value of constant parameter or the length of a timed run by pressing mode key and then the △ and ▽ keys. 9 stop of run when timer is timed or press the run key again to manually ...

  • Page 14

    F. Trouble shooting f-1. Instrument service if your elite 200 power supply is malfunction or operates unusually in any way. You may initially attempt to solve the problem by following the procedures in this section. All other servicing attempts will terminate the responsibility of the manufacturer u...

  • Page 15

    Symptom action and possible causes fan is not spinning led & display do not light up front panel power on indicator off 1. Check source wall power. 2. Replace a new configure fuse and try again. 3. Check if power switch malfunction. 4. Check if line voltage select error. 5. Contact your local wealte...

  • Page 16

    F-3. Error message error code explanation possible solution e1 no load detected the electrophoresis cell(s) are not plugged in. During a run, load current chopped more than 0.01a. *check all connections *check appropriate buffer volume. Press the run key to resume the run or any other key to clear t...

  • Page 17

    E4 power failure during a non-timed run press any key (other than run) to clear the error code. Then press the run key to resume the run. E5 power failure during a timed run (pfd off) press any key (other than run) to clear the error code. Then press the run key to restart the run. E6 power failure ...

  • Page 18

    G. Order information item # description 1001001 elite 200 power supply, 120v, 50-60hz 1001002 elite 200 power supply, 230v, 50-60hz 1001003 elite 300 power supply, 120v, 50-60hz 1001004 elite 300 power supply, 230v, 50-60hz 1001005 elite 300 plus power supply, 120v, 50-60hz 1001006 elite 300 plus po...

  • Page 19

    Appendix: service manual section 1 ─ ─ ─ ─ product description the 200v, 200w, electrophoresis power supply is a micro controller based, fly back converter power supply. The component designations used in the functional description refer to fig. Below. Emi filter bridge rectifies out put rectifies c...

  • Page 20

    Section 2 ─ ─ ─ ─ elite 200 function description the electrophoresis power supply is a micro controller based flyback converter power supply. The principle sections are the primary circuit, 200w power converter, control circuit and the front panel board. Primary circuit ac power is applied through s...

  • Page 21

    Control circuit r17 and r18 divide high voltage output to be a voltage sample signal. The voltage applies to a-d converter u13 ch0. At the same time the r21 current sense resistor converts the output current to a voltage. U7 condition this voltage and apply it to u13 ch1. Micro controller u11 sample...

  • Page 22

    Converts the pulsing to a digital signal. This digital signal is applied to missing pulse detector u12a. Once power failure is detected. The micro controller turns off the power converter and led to conserve power and stores the users running information in non-volatile memory u14. If the primary cu...

  • Page 23

    Section 3 ─ ─ ─ ─ service parts list e000001 up husk e000002 down husk e000003 fundus e000004 foudroyant housing e000005 foudroyant jacketing red e000006 foudroyant jacketing black e000007 foudroyant copperplate e000008 rubber e000009 dc12v fan e000010 filter e000011 power cord e000012 cable red e00...

  • Page 24

    Section 4 ─ ─ ─ ─ circuit diagram: as special request. 22.

  • Page 28

    02012 printed in taiwan wealtec corp. 1885 meadowvale way sparks, nv 89431 tel: (775) 351-2066 fax: (775) 351-2077 http://www.Wealtec.Com e-mail: support @wealtec.Com.