Webasto 0 Installation & Operation Manual

Manual is about: Webasto FCF Series Marine Air Conditioner

Summary of 0

  • Page 1

    Marine air conditioner installation & operation manual.

  • Page 3

    Table of contents introduction ........................................................................................................................................................4 overview .............................................................................................................

  • Page 4

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 4 introduction thank you for your purchase. No matter which of the following features was the reason for your purchase, we are sure it will meet your needs and provide many years of efficient and trouble free use. The fcf series...

  • Page 5

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 5 overview how it works your self-contained air conditioner consists of four main components and a refrigerant gas circulating through the system. The blower draws warm cabin air across the fins on the evaporator where the heat ...

  • Page 6

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 6 installation unpacking and inspection when the equipment is received, all items should be carefully checked against the packing list to ensure all cartons have been received. Move units in the normal "up" orientation as indica...

  • Page 7

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 7 placement of system selecting a good location for your air conditioner is the most important part of your preparation. Be sure to consider the size of the area you are cooling, the air distribution needs, and the size of the u...

  • Page 8

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 8 condensate drains the condensate drain pan is 2” (50mm) high with two drain locations. During conditions of high humidity, condensate may be produced at a rate of approximately a 1/2 gallon per hour (1.9 liters per hour). With...

  • Page 9

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 9 ducting good airflow is critical for the performance of the entire system. It is highly dependent on the quality of the ducting installation. The ducting should be run as straight, smooth and taut as possible minimizing the nu...

  • Page 10

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 10 tape on all threaded connections. Summary of the seawater system installation: 1. Install the speed scoop thru-hull inlet as close to the keel and as far below the water line as possible, facing forward. Bed the scoop with a ...

  • Page 11

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 11 electrical connections, grounding and bonding all a/c units have a terminal strip mounted inside the electric box. The terminal strip is labeled for proper connections of the electrical supply, ground wires and pump circuits....

  • Page 12

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 12 wired remote controller installation do not turn the unit off and immediately turn it back on. Wait at least 30 seconds for refrigerant pressures to stabilize. Before mounting the wired display, consider the location. The dis...

  • Page 13

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 13 installation checklist (review prior to installation) seawater cooling system: speed scoop located as far below the water line and as close to the keel as possible shut off valve (sea cock) and speed scoop properly sealed and...

  • Page 14

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 14 wiring diagrams power 115v ~ 60hz 115v ~ 60hz line in l 115v ~ 60hz neutral n cooling pump line in 1 cooling pump neutral 2 power 208v / 230v ~ 60hz 208v / 230v ~ 60hz line in l 208v / 230v ~ 60hz neutral n cooling pump line ...

  • Page 15

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 15 wiring diagram fcf 5,000 (115v/230v) – fcf 9,000 (115v/230v) (fcf 9,000 230v comes with a panasonic compressor; all other model are equip with samsung compressors) wiring diagram fcf 12,000 (115v/230v) – fcf 16,000 (115v/230v...

  • Page 16

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 16 operation wired display control operation don't install the wired display in a location where it can get wet. 1. Display receiver 6. Fan speed button 2. Digital display 7. Temp. Setting button / increasing 3. Fan speed displa...

  • Page 17

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 17 power on/off press on/off button to turn the unit on pressing the on/off button a second time will turn the unit off fan control press the fan button, the fan speed will change in the following order: → high →mid → low → auto...

  • Page 18

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 18 display fahrenheit or centigrade pressing the ▲ and ▼ key simultaneously, will switch between fahrenheit centigrade modes. Error codes when there are faults within the system, an error code will be displayed on the display co...

  • Page 19

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 19 when performing this setup or value change, ensure the wireless remote is not in site of any display as this could potentially change values prior to confirming set value. (make sure to confirm new values by simultaneously ho...

  • Page 20

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 20 remote control operation be sure that there are no obstructions between the remote and controller. ● the remote control signal can be received up to a distance of 33’ (10m). ● don't drop or throw the remote control. ● don't p...

  • Page 21

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 21 button / function and description (cover open) mode operations cool mode operation ● according to the difference between room temperature and set temperature, the microcomputer will decide if cooling mode is on or off. ● if r...

  • Page 22

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 22 dehumidify mode operation ● in dehumidify mode, if the indoor temperature is higher than temperature setting, the unit will operate in cooling mode and the fan will run on low speed ● set temperature should be in range of 61°...

  • Page 23

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 23 troubleshooting fault possible reason correction will not start a/c circuit breaker is off turn circuit breaker on at ship's panel, see control operation section in this manual. Display control is not turned on. Check wiring ...

  • Page 24

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 24 continued: fault possible reason correction low air flow air flow is blocked remove any obstructions in return air stream, clean return air filter and grille. Check for crushed or restricted ducting, ducting must be as straig...

  • Page 25

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 25 maintenance reversing valves reverse cycle units have a reversing valve; the valve must be energized periodically to keep the internal parts moving freely. To do this, switch the a/c unit into heat for a few seconds once a mo...

  • Page 26

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 26 winterization there are several methods of winterization, some of which work better than others. There are various methods employed using a 50/50 non-polluting biodegradable anti-freeze/water solution. Any method that causes ...

  • Page 27

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 27 unit dimensions & technical specifications unit dimensions & technical specifications btu capacity 5000 9000 12000 16000 capacity in kw 1.5 2.6 3.5 4.6 voltage 115v/230v 115v/230v 115v/230v 115v/230v frequency 60hz 60hz 60hz ...

  • Page 28

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 28 limited warranty this product comes with a 24 month limited warranty from the date of purchase. To obtain warranty service, contact a customer service representative at: (800) 860-7866 or e-mail at: . Technical assistance if ...

  • Page 29

    Operation / installation manual – fcf 5,000, 9,000, 12,000, 16,000 page 29 notes:.

  • Page 30

    Rev. B - date: may 7, 2009 webasto product n.A., inc. Technical assistance hotline phone: (800) 860-7866 outside u.S. (810) 593-6000