    Inhaltsverzeichnis 1 gesetzliche bestimmungen für den einbau . . . . . . . . . . . . . . . 1 2 verwendung / ausführung . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 einbauort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 typschild . . . . . . . ....

  • Page 3

    Sommaire 1 dispositions légales concernant le montage . . . . . . . . . . . . . . 57 2 application / exécution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 3 emplacement de montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 4 plaque signalétique . . . . . . . . . ...

  • Page 4

    Thermo 50 gesetzliche bestimmungen für den einbau 1 1 gesetzliche bestimmungen für den einbau 1.1. Gesetzliche bestimmungen für den einbau für das heizgerät thermo 50 bestehen typgenehmigungen nach den eg - richtlinien 72/245/ewg (emv) und 2001/56/eg (heizung) mit den eg-genehmigungs – nummern: e1*7...

  • Page 5

    Gesetzliche bestimmungen für den einbau thermo 50 2 2.4. Abgassystem 2.4.1. Der abgasauslass muss so angeordnet sein, dass ein eindringen von abgasen in das fahrzeuginnere über belüftungseinrichtungen, warmlufteinlässe oder fensteröffnungen verhindert wird. 2.5. Verbrennungslufteinlass 2.5.1. Die lu...

  • Page 6

    Thermo 50 verwendung / ausführung 3 2 verwendung / ausführung 2.1. Verwendung der wasserheizgeräte das wasserheizgeräte webasto thermo 50 dient in verbindung mit der fahrzeugeigenen heizanlage – zum beheizen des fahrgastinnenraumes – zum entfrosten der fahrzeugscheiben sowie – zum vorwärmen wasserge...

  • Page 7

    Einbauort thermo 50 4 3 einbauort das wasserheizgerät darf nur außerhalb des fahrgastraums eingebaut werden. Der einbau der heizgeräte erfolgt vorzugsweise im motorraum in gegen spritzwasser geschützte bereiche der vorderen kotflügel oder an der spritzwand. Der einbau der heizgeräte erfolgt möglichs...

  • Page 8

    Thermo 50 einbauort 5 bild 2: einbauzeichnung thermo 50 4 1 2 3 5 6 237 193 105,5 1 umwälzpumpe 2 brennstoffeintrittsstutzen 3 wasseraustrittsstutzen 4 abgasaustrittsstutzen 5 verbrennungsluft-eintritt 6 wassereintrittsstutzen thermo50_02_de_d.Fm seite 5 dienstag, 27. Mai 2003 11:53 11.

  • Page 9

    Typschild thermo 50 6 4 typschild das typschild muss an einer gegen beschädigung geschützten stelle liegen und im eingebauten zustand des heizgerätes gut sichtbar sein (oder typschild-duplikat verwenden). Die nichtzutreffenden jahreszahlen sind am typschild zu entfernen. Bild 3: typschild thermo50_0...

  • Page 10

    Thermo 50 einbaubeispiele 7 5 einbaubeispiele bild 4: einbaubeispiel für heizgerät thermo 50: thermostatkreislauf 1 kühler 2 kühlwasserthermostat 3 wasserpumpe (des fahrzeug-motors) 4 fahrzeug-motor mit serienmäßiger ausstattung 5 wasserheizgerät 6 batterie 7 sicherungshalter 8 steuergerät (im heizg...

  • Page 11

    Einbaubeispiele thermo 50 8 bild 5: einbaubeispiel für heizgerät thermo 50: bypass-einbindung mit rückschlagventil 1 kühler 2 kühlwasserthermostat 3 wasserpumpe (des fahrzeug-motors) 4 fahrzeug-motor mit serienmäßiger ausstattung 5 wasserheizgerät 6 batterie 7 sicherungshalter 8 steuergerät (im heiz...

  • Page 12

    Thermo 50 anschluss an das kühlsystem des fahrzeuges 9 6 anschluss an das kühlsystem des fahrzeuges bei thermostatkreisläufen sind nur thermostate mit einem Öffnungs- beginn das heizgerät wird an das kühlsystem des fahrzeuges entsprechend bild 4 und 5 angeschlossen. Die im kreislauf vorhandene kühlf...

  • Page 13

    Brennstoffversorgung thermo 50 10 7 brennstoffversorgung der brennstoff wird dem kraftsoffbehälter des fahrzeugges oder einem separaten brennstoffbehälter entnommen. Die angaben über zulässigen druck an der brennstoffentnahmestelle sind der folgenden tabelle zu entnehmen. Zulässige brennstoff- zulau...

  • Page 14

    Thermo 50 brennstoffversorgung 11 die brennstoffentnahme muss aus dem kraftstoffbehälter oder separa- tem tank erfolgen (siehe bild 8, 9 und 10). Mit dieser separaten brenn- stoffentnahme wird eine druckbeeinflussung ausgeschlossen. Hinweis: schnittstelle am tankentnehmer nach dem absägen entgraten ...

  • Page 15

    Brennstoffversorgung thermo 50 12 7.1. Brennstoffleitungen als brennstoffleitungen dürfen nur stahl-, kupfer- und kunststoffleitun- gen aus weich eingestelltem, licht- und temperaturstabilisiertem pa 11 oder pa 12 (z.B. Mecanyl rwtl) nach din 73378 verwendet werden. Hinweis: die schlauchschellen sin...

  • Page 16

    Thermo 50 brennstoffversorgung 13 7.3. Dosierpumpe die dosierpumpe ist ein kombiniertes förder-, dosier- und absperrsy- stem und unterliegt bestimmten einbaukriterien (siehe bild 7, 12 und 13). 7.3.1. Einbauort vor einbau der dosierpumpe ist sicherzustellen, dass der maximal auf- tretende druck an d...

  • Page 17

    Brennluftversorgung thermo 50 14 8 brennluftversorgung die brennluft darf auf keinen fall räumen entnommen werden, in de- nen sich personen aufhalten. Die brennluftansaugöffnung darf nicht in fahrtrichtung zeigen. Sie ist so anzuordnen, dass ein zusetzen durch verschmutzung, schneebewurf und ein ans...

  • Page 18

    Thermo 50 abgasleitung 15 9 abgasleitung die abgasleitung (innendurchmesser 22 mm) kann mit mehreren bie- gungen (zusammen 270°, kleinster biegeradius 50 mm) verlegt werden. Die abgasleitung darf gesamt nicht kürzer als 500 mm sein. Die maximale leitungslänge beträgt 1000 mm. Der abgasschalldämpfer ...

  • Page 19

    Elektrische anschlüsse thermo 50 16 10 elektrische anschlüsse 10.1. Anschluss steuergerät / heizgerät der elektrische anschluss der heizgeräte wird ausgeführt gemäß bild 17 bis 22. 10.2. Anschluss der bedienelemente das heizgerät kann über folgende webasto-bedienelemente ein- und ausgeschaltet werde...

  • Page 20

    Thermo 50 schaltpläne 17 11 schaltpläne 11.1. Legende für schaltpläne: ➀ fahrzeuggebläsesicherung im fahrzeug vorhanden ➁ mit plus an anschluss 10 = dauerbetrieb bei sofortheizen anschluss 10 offen = heizdauer ist variabel programmierbar (10 min bis 120 min); grundeinstellung 120 min ➂ dieser anschl...

  • Page 21

    Schaltpläne thermo 50 18 pos. Benennung bemerkung a1 heizgerät thermo 50 a2 steuergerät b2 temperaturfühler e glühstift / flammwächter f1 sicherung 15a flachsicherung sae j 1284 f2 sicherung 5a flachsicherung sae j 1284 f3 sicherung sicherung analog zu fahrzeug- gebläsesicherung (max. 20 a) h1 leuch...

  • Page 22

    Thermo 50 schaltpläne 19 bild 17: schaltplan für thermo 50, 24v vorwahluhr (legende siehe seite 17) ϑ ! " " " # ! ! ! ! ! ! ! $ % % % ! ! ! ! ! & ! ! ' ! ( ( ( ) thermo50_02_de_d.Fm seite 19 dienstag, 27. Mai 2003 11:53 11.

  • Page 23

    Schaltpläne thermo 50 20 bild 18: schaltplan für thermo 50, 24v schalter (legende siehe seite 17) ϑ ! ! ! " # $ $ % # & ! $ ' thermo50_02_de_d.Fm seite 20 dienstag, 27. Mai 2003 11:53 11.

  • Page 24

    Thermo 50 schaltpläne 21 bild 19: schaltplan für thermo 50, 24v vorwahluhr mit einem nebenantrieb (legende siehe seite 17) ϑ ! " # # # $ " " " " " " " " % & & & & " " " " " ! ' " " ( " ) ) ) ) & * " +, & - thermo50_02_de_d.Fm seite 21 dienstag, 27. Mai 2003 11:53 11.

  • Page 25

    Schaltpläne thermo 50 22 bild 20: schaltplan für thermo 50, 24v vorwahluhr mit zwei nebenantrieben (legende siehe seite 17) ! ! " ! ! ϑ ! ! # #! # $! % &! & & ' '! ! %" % ! %! % % % % % %" ( )! )" ) ) " ! ! ! ! ! ! % %! % % % $ * %" %! ! ! " + %! , ,! , )" ) ! - ! Thermo50_02_de_d.Fm seite 22 dienst...

  • Page 26

    Thermo 50 schaltpläne 23 bild 21: adr-schaltplan für thermo 50, 24v schalter mit einem nebenantrieb (legende siehe seite 17) ϑ ! " # # # $ " " " " " " " " % & & & & " " " " " ! ' " ( & ! % " ( # & " ) *+ " thermo50_02_de_d.Fm seite 23 dienstag, 27. Mai 2003 11:53 11.

  • Page 27

    Schaltpläne thermo 50 24 bild 22: adr-schaltplan für thermo 50, 24v schalter mit zwei nebenantrieben (legende siehe seite 17) ϑ ! " # # # $ $ " " " " " " " " % & & & & " " " " " ! ' " & & ! % " " ( # & ) " *+ thermo50_02_de_d.Fm seite 24 dienstag, 27. Mai 2003 11:53 11.

  • Page 28

    Thermo 50 erstinbetriebnahme 25 12 erstinbetriebnahme hinweis: die sicherheitshinweise in der bedienungs- und wartungsanweisung sind zu beachten! Die bedienungs- und wartungsanweisung vor inbetriebnahme des heizgerätes unbedingt lesen. Nach dem einbau des heizgerätes ist der wasserkreislauf sowie da...

  • Page 29

    Störungen thermo 50 26 13 störungen 13.1. Störabschaltung durch fehler am heizgerät bei nichtzustandekommen der flamme wird max. 180 sekunden brennstoff gefördert. Bei Überhitzung (auslösung des temperaturbegrenzers) wird die brennstoffzufuhr sofort gestoppt. In allen fällen (ausgenommen defekt am b...

  • Page 30

    Thermo 50 technische daten 27 14 technische daten die nebenstehenden technischen daten verstehen sich, soweit keine grenzwerte angegeben sind, mit den bei heizgeräten üblichen toleran- zen von ± 10 % bei einer umgebungstemperatur von +20 °c und bei nennspannung. 14.1. Brennstoff für thermo 50 (diese...

  • Page 31

    Technische daten thermo 50 28 thermo50_02_de_d.Fm seite 28 dienstag, 27. Mai 2003 11:53 11.

  • Page 32

    Thermo 50 statutory regulations governing installation 29 1 statutory regulations governing installation 1.1. Statutory regulations governing installation the thermo 50 heater has been type-tested and approved in accordance with ec directives 72/245/eec (emc) and 2001/56/ec (heater) with the followi...

  • Page 33

    Statutory regulations governing installation thermo 50 30 2.4. Exhaust system 2.4.1. The exhaust outlet must be positioned in such a way that exhaust gases cannot enter the vehicle via ventilation devices, hot-air inlets or window openings. 2.5. Combustion air inlet 2.5.1. The air for the combustion...

  • Page 34

    Thermo 50 use / version 31 2 use / version 2.1. Use of water heaters the webasto thermo 50 water heater is used in connection with the vehicle's own heating system – to heat the passenger compartment, – to defrost the vehicle windows and – to preheat water-cooled engines. The water heater operates i...

  • Page 35

    Installation position thermo 50 32 3 installation position the water heater must be installed outside the passenger compartment. The heaters are preferably installed in the engine compartment, in areas of the front fender where they are protected from splashing water or on the splashboard. The heate...

  • Page 36

    Thermo 50 installation position 33 fig. 2: thermo 50 installation drawing 4 1 2 3 5 6 237 193 105,5 1 circulation pump 2 fuel filler neck 3 water outlet connector 4 exhaust outlet connector 5 combustion air inlet 6 water inlet connector thermo50_02_gb_g.Fm seite 33 dienstag, 27. Mai 2003 12:08 12.

  • Page 37

    Rating plate thermo 50 34 4 rating plate the rating plate must be positioned so that it cannot be damaged and must still be clearly legible when the heater is installed (otherwise a duplicate rating plate must be used). Inapplicable years must be erased from the rating plate. Fig. 3: rating plate th...

  • Page 38

    Thermo 50 examples for installation 35 5 examples for installation fig. 4: example for installation of the thermo 50 heater: thermostat circuit 1 radiator 2 cooling water thermostat 3 water pump (of the engine) 4 engine with standard equipment 5 water heater 6 battery 7 fuse holder 8 control unit (i...

  • Page 39

    Examples for installation thermo 50 36 fig. 5: example for installation of the thermo 50 heater: bypass integration with non-return valve 1 radiator 2 cooling water thermostat 3 water pump (of the engine) 4 engine with standard equipment 5 water heater 6 battery 7 fuse holder 8 control unit (in the ...

  • Page 40

    Thermo 50 connection to the vehicle cooling system 37 6 connection to the vehicle cooling system in thermostat circuits, only use thermostats which start to open at the heater is connected to the vehicle cooling system as shown in figs. 4 and 5. At least 4 litres of coolant must be circulated. Note:...

  • Page 41

    Fuel supply thermo 50 38 7 fuel supply the fuel is taken from the vehicle fuel tank or from a separate fuel tank. The values for the permissible pressure at the fuel delivery point are listed in the following table. Permissible fuel inflow height h (m) max. Perm. Excess pressure (bar) in the fuel li...

  • Page 42

    Thermo 50 fuel supply 39 the fuel must be taken from the vehicle fuel tank or from a separate tank (see figs. 8, 9 and 10). This separate fuel pickup precludes any effect of pressure. Note: deburr the cut on the tank connector after sawing it off and remove any metal chips. Note on fig. 10: the fitt...

  • Page 43

    Fuel supply thermo 50 40 7.1. Fuel lines only steel, copper and plastic lines of plasticised, light and temperature- stabilised pa 11 or pa 12 (e.G. Mecanyl rwtl) in accordance with din 73378 may be used for the fuel lines. Note: the hose clips must be tightened with a torque of 1.0 + 0.4 nm. Leakin...

  • Page 44

    Thermo 50 fuel supply 41 7.3. Metering pump the metering pump is a combined delivery, metering and shutoff system and is subject to specific installation criteria (see figs. 7, 12 and 13). 7.3.1. Installation position before installing the metering pump, ensure that the maximum pressure occurring at...

  • Page 45

    Combustion air supply thermo 50 42 8 combustion air supply under no circumstances may the combustion air be taken from areas occupied by people. The combustion air intake opening must not point in the direction of travel. It must be located so that it cannot become clogged with dirt or snow and cann...

  • Page 46

    Thermo 50 exhaust line 43 9 exhaust line the exhaust line (inside diameter 22 mm) can be routed with several bends (270° altogether, minimum bending radius 50 mm). The total length of the exhaust line must be not less than 500 mm. The maximum line length equals 1000 mm. The exhaust muffler should pr...

  • Page 47

    Electrical connections thermo 50 44 10 electrical connections 10.1. Connection of control unit / heater the electrical connection of the heaters is made as shown in figs. 17 to 22. 10.2. Connecting the controls the heater can be switched on and off using the following webasto controls: – timer see c...

  • Page 48

    Thermo 50 circuit diagrams 45 11 circuit diagrams 11.1. Legend for circuit diagrams: ➀ vehicle fan fuse installed in vehicle ➁ with positive at connection 10 = continuous operation with immediate heating connection 10 open = variable heating duration can be programmed (10 min to 120 min); default se...

  • Page 49

    Circuit diagrams thermo 50 46 item designation comment a1 heater thermo 50 a2 control unit b2 temperature sensor e glow plug / flame monitor f1 fuse 15 a flat fuse sae j 1284 f2 fuse 5 a flat fuse sae j 1284 f3 fuse fuse same as vehicle fan fuse (max. 20 a) h1 led (in item p) switch-on indicator h2 ...

  • Page 50

    Thermo 50 circuit diagrams 47 fig. 17: circuit diagram for thermo 50, 24 v timer (legend see page 45) ϑ ! " " " # ! ! ! ! ! ! ! $ % % % ! ! ! ! ! & ! ! ' ! ( ( ( ) thermo50_02_gb_g.Fm seite 47 dienstag, 27. Mai 2003 12:08 12.

  • Page 51

    Circuit diagrams thermo 50 48 fig. 18: circuit diagram for thermo 50, 24 v switch (legend see page 45) ϑ ! ! ! " # $ $ % # & ! $ ' thermo50_02_gb_g.Fm seite 48 dienstag, 27. Mai 2003 12:08 12.

  • Page 52

    Thermo 50 circuit diagrams 49 fig. 19: circuit diagram for thermo 50, 24 v timer with one auxiliary power take-off (legend see page 45) ϑ ! " # # # $ " " " " " " " " % & & & & " " " " " ! ' " " ( " ) ) ) ) & * " +, & - thermo50_02_gb_g.Fm seite 49 dienstag, 27. Mai 2003 12:08 12.

  • Page 53

    Circuit diagrams thermo 50 50 fig. 20: circuit diagram for thermo 50, 24 v timer with two auxiliary power take-offs (legend see page 45) ! ! " ! ! ϑ ! ! # #! # $! % &! & & ' '! ! %" % ! %! % % % % % %" ( )! )" ) ) " ! ! ! ! ! ! % %! % % % $ * %" %! ! ! " + %! , ,! , )" ) ! - ! Thermo50_02_gb_g.Fm se...

  • Page 54

    Thermo 50 circuit diagrams 51 fig. 21: adr circuit diagram for thermo 50, 24 v switch with one auxiliary power take-off (legend see page 45) ϑ ! " # # # $ " " " " " " " " % & & & & " " " " " ! ' " ( & ! % " ( # & " ) *+ " thermo50_02_gb_g.Fm seite 51 dienstag, 27. Mai 2003 12:08 12.

  • Page 55

    Circuit diagrams thermo 50 52 fig. 22: adr circuit diagram for thermo 50, 24 v switch with two auxiliary power take-offs (legend see page 45) ϑ ! " # # # $ $ " " " " " " " " % & & & & " " " " " ! ' " & & ! % " " ( # & ) " *+ thermo50_02_gb_g.Fm seite 52 dienstag, 27. Mai 2003 12:08 12.

  • Page 56

    Thermo 50 initial start-up 53 12 initial start-up note: the safety instructions in the operating and maintenance instructions must be observed without fail. The operating and maintenance instructions must be read through without fail before starting the heater. After installation of the heater, care...

  • Page 57

    Faults thermo 50 54 13 faults 13.1. Fault lock-out due to faults in the heater fuel is supplied for max. 180 seconds if the flame does not start to burn. The fuel supply is shut off immediately if the system overheats (temperature limiter is tripped). In all cases (except a fault in the combustion a...

  • Page 58

    Thermo 50 technical data 55 14 technical data except where limit values are specified, the technical data on the right refer to the usual heater tolerances of ± 10 % at an ambient temperature of +20 °c and at nominal voltage. 14.1. Fuel for thermo 50 (diesel / pme): diesel oil or pme fuel authorised...

  • Page 59

    Technical data thermo 50 56 thermo50_02_gb_g.Fm seite 56 dienstag, 27. Mai 2003 12:08 12.

  • Page 60

    Thermo 50 dispositions légales concernant le montage 57 1 dispositions légales concernant le montage 1.1. Dispositions légales concernant le montage le chauffage thermo 50 a été soumis à une procédure de réception selon modèle-type conformément aux directives ce 72/245/cee (cem) et 2001/56/ce (chauf...

  • Page 61

    Dispositions légales concernant le montage thermo 50 58 2.4. Système d'échappement 2.4.1. L'orifice d'échappement doit être situé à un endroit tel que ses rejets ne puissent s'infiltrer à l'intérieur du véhicule par les ventilateurs, les entrées d'air chaud ou les ouvertures des fenêtres. 2.5. Entré...

  • Page 62

    Thermo 50 application / exécution 59 2 application / exécution 2.1. Application des chauffages à eau le chauffage à eau webasto thermo 50 sert en lien avec le système de chauffage propre au véhicule – pour chauffer l'habitacle, – dégivrer le pare-brise et – préchauffer les moteurs à refroidissement ...

  • Page 63

    Emplacement de montage thermo 50 60 3 emplacement de montage le chauffage à eau doit impérativement être installé en dehors de l'habitacle. Il s'installe de préférence dans le compartiment moteur, dans la zone protégée des éclaboussures de l'aile avant ou au niveau du tablier. Le chauffage est à ins...

  • Page 64

    Thermo 50 emplacement de montage 61 fig. 2: schéma de montage du thermo 50 4 1 2 3 5 6 237 193 105,5 1 pompe de circulation 2 raccord d'arrivée de carburant 3 raccord de sortie d'eau 4 raccord de sortie des gaz d'échappement 5 entrée air de combustion 6 raccord d'arrivée d'eau thermo50_02_fr_g.Fm se...

  • Page 65

    Plaque signalétique thermo 50 62 4 plaque signalétique la plaque signalétique doit se trouver en un endroit protégé contre les dommages et doit être bien visible lorsque le chauffage est monté (sinon utilisé un duplicata de la plaque signalétique). Il faut supprimer les chiffres des années sans obje...

  • Page 66

    Thermo 50 exemples de montage 63 5 exemples de montage fig. 4: exemple de montage pour le chauffage thermo 50 : circuit du thermostat 1 radiateur 2 thermostat de liquide de refroidissement 3 pompe à eau (du moteur du véhicule) 4 moteur du véhicule avec équipement de série 5 chauffage à eau 6 batteri...

  • Page 67

    Exemples de montage thermo 50 64 fig. 5: exemple de montage pour le chauffage thermo 50 : intégration en dérivation avec clapet antiretour 1 radiateur 2 thermostat de liquide de refroidissement 3 pompe à eau (du moteur du véhicule) 4 moteur du véhicule avec équipement de série 5 chauffage à eau 6 ba...

  • Page 68

    Thermo 50 raccordement au circuit de refroidissement du véhicule 65 6 raccordement au circuit de refroidissement du véhicule dans les circuits à thermostat, utiliser uniquement des thermostats à début d'ouverture le chauffage est raccordé au circuit de refroidissement du véhicule con- formément aux ...

  • Page 69

    Alimentation en carburant thermo 50 66 7 alimentation en carburant le carburant provient du réservoir de carburant du véhicule ou d'un réservoir de combustible indépendant. Le tableau suivant contient les indications de pression admissible au niveau du point de prélèvement du carburant. Charge diffé...

  • Page 70

    Thermo 50 alimentation en carburant 67 le prélèvement du combustible doit s'effectuer à partir du réservoir du véhi- cule ou d'un réservoir indépendant (voir figures 8, 9 et 10). Ce prélève-ment séparé du combustible permet d'éviter toute influence sur la pression. Nota ebarber l'endroit de la décou...

  • Page 71

    Alimentation en carburant thermo 50 68 7.1. Conduites de carburant les conduites de carburant doivent exclusivement être composées de conduites en acier, en cuivre ou en matière plastique pa 11 ou pa 12 tendre, stabilisée à la lumière et à la température (par exemple mecanyl rwtl) conformes à din 73...

  • Page 72

    Thermo 50 alimentation en carburant 69 7.3. Pompe de dosage la pompe de dosage est un système combiné de transport, de dosage et de blocage qui est soumis à des critères de montage bien précis (voir figures 7, 12 et 13). 7.3.1. Emplacement de montage avant d'installer la pompe de dosage, il faut s'a...

  • Page 73

    Alimentation en air de combustion thermo 50 70 8 alimentation en air de combustion en aucun cas, l'air de combustion ne doit être prélevé dans un espace où séjournent des personnes. L'orifice d'aspiration d'air de combustion ne doit pas être dirigé dans le sens du déplacement. Il est à placer de man...

  • Page 74

    Thermo 50 conduite d'échappement 71 9 conduite d'échappement la conduite d'échappement (diamètre intérieur 22 mm) peut être posée avec plusieurs courbures (au total 270°, plus petit rayon de courbure 50 mm). La conduite d'échappement doit avoir une longueur minimum totale de 500 mm. La longueur maxi...

  • Page 75

    Branchements électriques thermo 50 72 10 branchements électriques 10.1. Branchement du module de commande / chauffage le branchement électrique du chauffage s'effectue conformément aux figures 17 bis 22. 10.2. Branchement des éléments de commande le chauffage peut être mis en marche ou arrêté à part...

  • Page 76

    Thermo 50 schémas électriques 73 11 schémas électriques 11.1. Légende des schémas électriques ➀ fusible existant de la ventilation du véhicule ➁ avec plus au raccordement 10 = chauffage instantané en mode continu raccordement 10 ouvert = la durée de chauffage est programmable à volonté (de 10 mn à 1...

  • Page 77

    Schémas électriques thermo 50 74 n° désignation remarque a1 chauffage thermo 50 a2 module de commande b2 sonde de température e bougie / détecteur d'allumage f1 fusible 15 a fusible plat sae j 1284 f2 fusible 5 a fusible plat sae j 1284 f3 fusible même fusible que celui de la venti- lation du véhicu...

  • Page 78

    Thermo 50 schémas électriques 75 fig. 17: schéma électrique pour thermo 50, horloge de programmation 24 v (légende : voir page 73) ϑ ! " " " # ! ! ! ! ! ! ! $ % % % ! ! ! ! ! & ! ! ' ! ( ( ( ) thermo50_02_fr_g.Fm seite 75 dienstag, 27. Mai 2003 11:55 11.

  • Page 79

    Schémas électriques thermo 50 76 fig. 18: schéma électrique pour thermo 50, commutateur 24 v (légende : voir page 73) ϑ ! ! ! " # $ $ % # & ! $ ' thermo50_02_fr_g.Fm seite 76 dienstag, 27. Mai 2003 11:55 11.

  • Page 80

    Thermo 50 schémas électriques 77 fig. 19: schéma électrique pour thermo 50, horloge de programmation 24 v avec commande auxiliaire (légende : voir page 73) ϑ ! " # # # $ " " " " " " " " % & & & & " " " " " ! ' " " ( " ) ) ) ) & * " +, & - thermo50_02_fr_g.Fm seite 77 dienstag, 27. Mai 2003 11:55 11.

  • Page 81

    Schémas électriques thermo 50 78 fig. 20: schéma électrique pour thermo 50, horloge de programmation 24 v avec double commande auxiliaire (légende : voir page 73) ! ! " ! ! ϑ ! ! # #! # $! % &! & & ' '! ! %" % ! %! % % % % % %" ( )! )" ) ) " ! ! ! ! ! ! % %! % % % $ * %" %! ! ! " + %! , ,! , )" ) ! ...

  • Page 82

    Thermo 50 schémas électriques 79 fig. 21: schéma électrique adr pour thermo 50, commutateur 24 v avec commande auxiliaire (légende : voir page 73) ϑ ! " # # # $ " " " " " " " " % & & & & " " " " " ! ' " ( & ! % " ( # & " ) *+ " thermo50_02_fr_g.Fm seite 79 dienstag, 27. Mai 2003 11:55 11.

  • Page 83

    Schémas électriques thermo 50 80 fig. 22: schéma électrique adr pour thermo 50, commutateur 24 v avec double commande auxiliaire (légende : voir page 73) ϑ ! " # # # $ $ " " " " " " " " % & & & & " " " " " ! ' " & & ! % " " ( # & ) " *+ thermo50_02_fr_g.Fm seite 80 dienstag, 27. Mai 2003 11:55 11.

  • Page 84

    Thermo 50 première mise en service 81 12 première mise en service nota respecter les consignes de sécurité de la notice d'utilisation et d'entretien ! Il faut impérativement lire la notice d'utilisation et d'entretien avant de mettre le chauffage en service. Purger soigneusement le circuit d'eau et ...

  • Page 85

    Défauts thermo 50 82 13 défauts 13.1. Arrêt sur défaut en raison d'un dérangement au niveau du chauffage si la flamme n'apparaît pas, l'arrivée de carburant se poursuit pendant 180 secondes au maximum. L'arrivée de carburant est stoppée immédiatement en cas de surchauffe (déclenchement du limiteur d...

  • Page 86

    Thermo 50 caractéristiques techniques 83 14 caractéristiques techniques si aucune valeur limite n'est précisée, les caractéristiques techniques ci-contre s'entendent avec les tolérances de ± 10 % habituelles pour les appareils de chauffage sous une température ambiante de +20 °c et sous tension nomi...

  • Page 87

    Caractéristiques techniques thermo 50 84 thermo50_02_fr_g.Fm seite 84 dienstag, 27. Mai 2003 11:55 11.