If you have separate power for RH and RC then you will need to remove the factory
installed jumper between RH and RC.
Many systems do not provide a “C” common wire, so 4 AA batteries must be installed
before the unit will operate.
After you have made the necessary connections and have mounte the new thermostat to
the wall, turn on the breakers to your HVAC system.
NOTE: This thermostat is equipped with an auto-sensing mode that detects your system
type by the wiring connections made. The thermostat will display “E0” until the unit has
been properly connected and reset (by pulling front panel off and re-attaching).
From the factory the thermostat comes configured to work with single-stage cool, single-
stage heat (non-heat pump), Single Speed Fan systems.
If your HVAC system is different, refer to the programming section to configure the
thermostat for your system.
Entering Programming Mode
First, press the MODE button until “off” is displayed. Then swipe one finger down the
right slider while holding the empty space between the HOLD and FAN buttons. The
display will change to “01” to indicate that you are in programming mode.
Navigating Programming Mode
HOLD Enter Menu / Save Settings
MODE Exit Menu Item
(+) and (-) Cycle Menu Options / Settings
Programming Thermostat for a Heat Pump
1. Enter programming mode.
2. Press (+) until the display reads “02”.
3. Press HOLD, then press (+) until the display reads “01”...then press HOLD again to
save changes.
4. Tap the MODE button until the thermostat display returns to its normal state.
Auto-sensing Mode
Based on the wiring configuration from the “Installing Your Thermostat” section, the
thermostat automatically detects which type of heat pump system your HVAC system
utilizes.
Programming Thermostat for a Gas or Oil Heat
1. Enter programming mode.
2. Press (+) until the display reads “03”.
3. Press HOLD, then press (+) until the display reads “01”...then press HOLD again to
save changes.