  • Page 1

    Rgb elektronika agaciak ciaciek spÓŁka jawna jana dlugosza 2-6 street 51-162 wrocław poland biuro@rgbelektronika.Pl +48 71 325 15 05 www.Rgbautomatyka.Pl www.Rgbelektronika.Pl datasheet www.Rgbautomatyka.Pl www.Rgbelektronika.Pl other symbols: sor3 weber.

  • Page 2: Our Services

    Your partner in maintenance at our premises in wrocław, we have a fully equipped servicing facility. Here we perform all the repair works and test each later sold unit. Our trained employees, equipped with a wide variety of tools and having several testing stands at their disposal, are a guarantee o...

  • Page 3

    Anl_sor_en_02-10.Doc 08/09 weber schraubautomaten gmbh hans-urmiller-ring 56 d-82515 wolfratshausen tel.: 0049 (8171) 406-0 e-mail: info@weber-online.Com fax.: 0049 (8171) 406-111 www.Weber-schraubautomaten.De user’s manual sor 3 frequency controller for vibratory feeders.

  • Page 4

    User’s manual sor 3 1 safety notice for the user this description contains the required information about the intended usage of the products described herein. It is intended for use by technically qualified personnel. Qualified personnel are those persons who, due to their training, experience and i...

  • Page 5

    User’s manual sor 3 2 table of contents safety notice for the user............................................................................................................................. 1 table of contents ...........................................................................................

  • Page 6

    User’s manual sor 3 3 1.0 general the controllers of the production series sor are microprocessor-controlled devices for the adjustment of the transport quantity for oscillating conveyors. The devices generate a power supply independent of the output frequency for the conveyor so that a precise tuni...

  • Page 7

    User’s manual sor 3 4 4.0 technical data type sor 3 supply power connection 100...230 v, +/- 10 %, 50/60 hz output 0...210 v, 0...3 a / (0...100 v, 0...3 a) recommended* master fuse 10 a slow blow circuit breaker 16 a, trigger charac- teristic “d“ release input 24 v, dc operating temperature 0...+45...

  • Page 8

    User’s manual sor 3 5 7.0 adjustment possibilities after alignment of the controller associated with the oscillating conveyor, the necessary adjust- ments by the user are limited to the setup of the conveyor capacity. Parameter: code basic factory adjustment: access code: oscillating conveyor • osci...

  • Page 9

    User’s manual sor 3 6 9.0 placing in operation 9.1 preliminary measures • check whether the local supply power is compatible with that of the device (refer to name plate) and that the connection value of the conveyor is within the allowable power range. • connect controller according to the delivere...

  • Page 10

    User’s manual sor 3 7 10.0 adjustment depressing the programmer key “p” initializes each type of setup. 1. Depress “p key”. 2. With arrow keys, scroll to desired code number. 3. Depress “p key”. The first menu point will appear. If necessary, search further for the desired menu point with the “p key...

  • Page 11

    User’s manual sor 3 8 11.0 error messages error messages are displayed in short form with “error“, blinking alternatively. Overload limit short circuit shutdown main power over-voltage or feedback from magnet by depressing the “p” key or by an off and on switching of the main power switch, the devic...

  • Page 12

    User’s manual sor 3 9 13.0 device connections in order to meet the emi requirements, a shielded output cable to the conveyor must be used. 1 2 3 4 1 pe 2 3 1 p e 2 3 main supply 110 / 230 v, 50/60 hz pe 3 4 1 1 = l 2 = n 3 = nc 4 = pe 1 = a1 2 = a2 3 = screen 4 = pe 1 2 3 pe output feeder enable inp...