Weber Summit 42376 Installation & Owners Manual

Manual is about: BUILT-IN LP SIDE BURNER

Summary of Summit 42376

  • Page 1

    Built-in lp side burner installation/owner's guide 42376 us 01/10/06 lp you must read this owners guide before operating your gas grill danger if you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open fl ames. 3. Open lid. 4. If odor continues, keep away from the appliance and immed...

  • Page 2

    2 dangers & warnings danger failure to follow the dangers, warnings and cautions contained in this owner’s manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property. Warnings do not store a spare or disconnected liquid propane cylinder under or nea...

  • Page 3

    3 storage and/or nonuse • the gas must be turned off at the liquid propane cylinder when the weber ® gas barbecue is not in use. Operating warning: only use this barbecue outdoors in a well-ventilated area. Do not use in a garage, building, breezeway or any other enclosed area. Warning: your summit®...

  • Page 4

    4 locating your built-in side burner when determining a suitable location for your built-in side burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the sum- mit ® built-in side bur...

  • Page 5

    5 mounting the side burner connect the corrugated gas line to the side burner valve located on the back right hand side of side burner. Test connections all connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of an...

  • Page 6

    6 typical bulk propane gas supply installation we recommend that this installation be done by a licensed professional. General specifi cations for piping note - contact your local municipality for building codes regulating outdoor gas grill installations. In absence of local codes, you must conform ...

  • Page 7

    7 typical 20 lp propane gas supply installation we strongly recommend that you use the summit ® built-in tank cabinet (#21280) for installations using a 20 lb lp cylinder, mounted remotely in an “island” structure. The summit ® built-in tank cabinet is a csa listed accessory for installing a remote ...

  • Page 8

    8 3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch. D). The remote lp cylinder enclosure should be constructed with non- combustible materials. The remote lp cylinder enclosure should isolate the lp cylinder from the burner compartment, so that it provides shielding ...

  • Page 9

    9 gas instructions fill liquid propane cylinder to fi ll, take the liquid propane cylinder and fi ller adapter to an rv center or look up gas-propane in the phone book for other sources of liquid propane gas. Warning: we recommend that your liquid propane cylinder be fi lled at an authorized liquid ...

  • Page 10

    10 to connect the hose to the cylinder: 3) remove the plastic dust cover from the valve. 4) screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-tighten only. Note: this connection tightens clockwise and will not allow gas to fl ow unless the connection is tight. The co...

  • Page 11

    11 check: 3) “t” connection-to-hose connections. 4) the hose-to-regulator connection. Warning: if there is a leak at connections (2,3, or 4), turn off the gas. Do not operate the grill. Contact customer service 1-800-446-1071. When leak checks are complete, turn gas supply off at the source and rins...

  • Page 12

    12 lighting the side burner. 1) open the side burner lid. 2) check that the side burner valve is turned off. (push knob in and turn clockwise to ensure that it in the off position.) warning: the burner control knob must be in the off position before turning on the liquid propane cylinder valve. If i...

  • Page 13

    13 crossover ® ignition system operations if the crossover ® ignition system fails to ignite the left burner in a burner set, light the left burner with a match. If the left burner lights with a match, then check the crossover ® ignition system. • check that both ignition wires(1,2) are attached pro...

  • Page 14

    14 problem check cure side burner does not light. Is gas supply off? Turn supply on. Flame is low in high position. Is the fuel hose bent or kinked? Straighten hose. Is lp fuel low or empty? Refi ll lp cylinder. The excess fl ow safety device, which is part of the barbecue to cylinder connection, ma...

  • Page 15

    15 attention: this product has been safety tested and is only certifi ed for use in a specifi c country. Refer to country designation located on outer carton. These parts may be gas carrying or gas burning components. Please contact weber-stephen products co., customer service department for genuine...

  • Page 16

    ©2003 the following trademarks are registered in the name of weber-stephen products co., an illinois corporation, located at 200 east daniels road, palatine, illinois 60067 u.S.A. Australia; smokey joe, weber, kettle silhouette ® , genesis, austria; kettle silhouette ® , smokey joe, weber, benelux; ...