Page 8
Interfaces, Push buttons, Switches, Display, LED Indicators, Inputs, Outputs, and Power
Interfaces - IP/GPRS
Ethernet
Antenna
Serial RS232
– 3 wires: Transmit, Receive & Return path ground
Serial RS485
– 3 wires: A, B, & Return path ground
Serial TTL
– 3 wires: Transmit, Receive & Return path ground
Console port
Interfaces
– GPRS/PSTN
In addition to IP/GPRS interfaces:
Telephone line
– a and b
Extension wiring
– a and b
Push Buttons
A, B, & C
DIP Switches
Switch
Description
Notes
Switch 1
IP/GPRS - force Ethernet FAIL
GPRS/PSTN - force PSTN FAIL
Return to OFF after test procedure
Switch 2
Force GPRS FAIL
Return to OFF after test procedure
Switch 3
MENU
Factory setting
– do not change
Switch 4
DISP
Factory setting
– do not change
Switch 5
MODE
Factory setting
– do not change
Switch 6
RUN/BOOT
Factory setting
– do not change
Switch 7
33/66
Set to ON when using, Imaging, Modem Capture & Audio Capture module
Switch 8
HIGH/LOW
Factory setting
– do not change
Switch 9
SOFT
Factory setting
– do not change
Switch 10
TERM
Factory setting
– do not change
Display
Starburst display
LED Indicators
Legend
Indicator
Description
PNL
Panel indicator
Shows the data flow for the serial alarm panel interface
- Red for data from the alarm panel to the WebWay
- Green for data from the WebWay to the alarm panel
EXT
External port interface
indicator
Shows the data flow for the optional serial alarm panel interface
- Red for data from the external device to the WebWay
- Green for data from the WebWay processor to the external device
ATS
Path and interface status
Shows the status of each transmission interface and path.
The indicator flashes once for each path followed by a gap.
Each flash provides the following status indications:
Green
– Good path on good interface
Orange
– Bad interface
Red
– Bad path (no communication with ARC) but interface good
MSG
Message status
Message queue status indication
Indicates the status of the queue of messages being sent to the ARC
Red
– Messages are queued and have not been sent
Green
– Messages have been sent but not acknowledged
Orange
– Messages waiting to be sent plus messages sent and waiting to be
acknowledged
Off
– No messages waiting to be sent or waiting to be acknowledged
SMG
Commission status
Indicates the configuration and commission status of the WebWay
Flashing Green (sometimes with a hint of orange)
– Commissioned
Flashing Orange
– Initialising, system not ready yet
Red / Green Alternate
– Not commissioned
Flashing Red
– Not Commissioned
Ethernet data
Green on
– 10BaseT
Green off
– 100BaseT
Red - Data activity to and from the LAN