  • Page 1

    Airflame excel mk.3 remote control af 18xl rc 9500374 ac 18xl rc 9500375 users manual patent applied for 9860380/03 please leave these instructions with the user this appliance is for use in the united kingdom (gb) and the republic of ireland (ie) only..

  • Page 2

    2 please note 1. The wonderfire airflame excel is to be used only with the type of gas for which it was supplied. Never attempt to use the appliance with other gas types. 2. Always use a fireguard complying with bs6539 or bs6778 for the protection of the young, elderly, or infirm. 3. The fire is lit...

  • Page 3

    3 ventilation requirements note: see convector instructions if being installed within a wonderfire convector box for ventilation requirements. Gb a permanent ventilation grille of fixed design and having a minimum free area of 100cm 2 must be fitted with direct access to outside air to room. Ie vent...

  • Page 4

    4 operation of the fire – continued observe if it is alight by looking through the slots to the left hand end of the front coals. If the pilot does not light immediately, repeat the above procedure, keeping the knob depressed for several seconds in order to purge any air from the system. If after te...

  • Page 5

    5 figure 5 figure 6 in order to vary the flame effect between ‘high’ and ‘low’ position, press, and keep depressed, either the ‘high flame’ (or ‘on’) button, or the ‘low flame’ (or ‘off’) button as appropriate. Refer to figure 4. In order to switch the fire to pilot setting, depress the ‘low flame’ ...

  • Page 6

    6 figure 8 • to return to the fully aerated position push the control lever in and slightly downwards until it rests in its locked position. Please note : it is advisable to run the fire in its fully aerated mode (control knob pushed in) at the beginning of each operation and if running at the minim...

  • Page 7

    7 placing the dress coals the dress coals consist of: • 6 x finger coals • 18 x random cut coals keep the different types of coals separate. Begin the coal build by placing six random shaped coals as shown in figure 10, ensuring that they form a bridge between the front coal and the coal matrix. In ...

  • Page 8

    8 placing the dress coals – continued figure 13 next, take four finger coals and position as shown in figure 13. ‘a’ ‘b’ ‘b’ ‘c’ figure 14 ‘c’ finally, take the three remaining random shaped coals. Place one in the centre of the matrix (position ‘a’), place the other two next to it (position ‘b’) as...

  • Page 9

    9 spare parts the ceramic fuel bed items are customer replaceable. When ordering please quote the number shown below. Only use genuine wonderfire replacement parts in the correct quantity, and follow the instructions carefully. Description part number front coal 9770100 coal matrix 9770099 pack of d...

  • Page 10

    10 legal requirement every gas appliance should be installed by a competent person. If in doubt always use the services of a corgi registered installer. Please fill in the following information for your own future reference. This information should always be quoted in any correspondence with your or...