Wonwoo Rapport 337 User Manual

Manual is about: Professional CCTV Tester

Summary of Rapport 337

  • Page 1

    Www.Rapport337.Com.

  • Page 2

    Manufacturer : wonwoo engineering co., ltd. Www. Rapport337.Com made in korea distributed by:.

  • Page 3

    T table of contents before reading the user's manual 1 1. Safety information 2 warning 2 2. Introduction of rapport337 7 names & functions of each part 9 3. Specifications of rapport337 14 general specifications 14 meter specifications 15 4. Functional use 17 power on/off 17 osd setup screen when po...

  • Page 4

    Memo.

  • Page 5

    B bef or e reading the user Õ s manual w a r n i n g make sure to read through "safety information" before using rapport337. This basic instruction manual is for users of rapport337. Starting with the outline of rapport337, the manual is emphasized on the explanations of its operation, how to be con...

  • Page 6

    1 1 . Saf ety inf or mation 2 w a r n i n g ඝ the following is important to use rapport337 safely. First of all, read through "the precautions for your safety " before using the system. Make sure to check the input and output range of voltage or current at every input and output ports of rapport337 ...

  • Page 7

    The following operational environment should be maintained constantly for the proper use of rapport337. 㯲 㯲 temperature : -10 ୅ ~ 50 ୅ 㯲 relative humidity : 30% ~ 90% 㯲 recharging voltage : 12v ·g10%, above 1a 1 . Saf ety inf or mation 3 when the meter function is being used, do not connect any devi...

  • Page 8

    4 w a r n i n g ඝ pay attention to the following precautions when using rapport337. Do not use the unit in damp humidity or leaking gas environments. Do not touch it with wet hands. Be mindful not to shock or shake the unit while in use to avoid damage. Avoid the places of strong magnetism or electr...

  • Page 9

    1 . Saf ety inf or mation 5 w a r n i n g ඝ battery charging & its precautions with the rechargeable 6 nickel hydrogen (ni-mh) aa-size batteries placed in, rapport337 can be charged with an adopter of above dc 12v, 1a, and it takes more than 8 hrs for the battery to be fully charged. The battery ope...

  • Page 10

    6 - cautions for battery - the following batteries can be used for rapport337 - (aa)-size alkaline battery (6ea) - (aa)-size chargeable nickel hydrogen (ni-mh) battery (6ea) use only chargeable nickel hydrogen (ni-mh) batteries, when charging batteries,using an adapter to rapport337. Place the charg...

  • Page 11

    2 . Intr oduction of rappor t3 3 7 7 features as a handy and portable device designed for testing various appliances, for the image-output equipments to be installed, rapport337 is an efficient tester with useful testing functions, to assist the installation of cctv, utp test, communications test, r...

  • Page 12

    8 standard items check the contents of your rapport337 package with the standard checklist below placing them on a level place. Rapport337 main body user's manual test lead set(red, black) adapter rechargeable aa(size) nickel hydrogen(ni-mh) battery (6ea) necklace utp test terminal bnc video cable c...

  • Page 13

    2 . Intr oduction of rappor t3 3 7 9 ඝ names & functions of each part 10a ma v/ far +tele - set mode osd pwr nea r wid e pwr chg rx tx bright contrast 1 2 4 5 6 7 8 3 max 400ma 10a max 400v ac max 500v max 400v dc fused un fused rapport337 www.Rapport337.Com.

  • Page 14

    10 part name function ྞ key button controlling external devices of rapport337 mode button set button osd button far button near button tele button wide button shift setup button mode select (video, multi meter, ptz control, utp test) it is used when setup is changed it toggles osd & power on/off it ...

  • Page 15

    2 . Intr oduction of rappor t3 3 7 11 part name function ྟ key button meter part ྠ test lead connection test lead positioning for lead connection resistance button voltage button setup change button current measuring button 1 current measuring button 2 current measuring button 3 hold, help button it...

  • Page 16

    12 part ྙ ྚ ྛ ྜ ྜྷ ྞ 1 2 5 4 6 3 name input bnc output bnc communication port base safety hook up safety hook down function it inputs external image signal it outpus input image signal to rapport337 or internally generated video test signals it is the port of input & output of communication signal.(r...

  • Page 17

    2 . Intr oduction of rappor t3 3 7 13 part ྙ ྚ ྛ ྜ 1 4 2 3 name utp jack aux jack dc power jack power s/w function test jack for utp cable audio, aux input port (function to be added when upgraded) dc power input jack(for over dc12v,1a) on/off main power supply www.Rapport337.Com.

  • Page 18

    3 3 . Specif ications of rappor t3 3 7 14 ඝ general specifications electric characteristic image ptz operation test utp cable test size input voltage battery built-in charger tv type image level protocol transmission speed transmission mode kinds of test 12v · 10%, above 1a chargeable ni-mh battery ...

  • Page 19

    3 . Specif ications of rappor t3 3 7 15 ඝ meter specifications dc voltage ac voltage dc current 400mv 4v 4v 400v 4v 40v 400v 100uv 1mv 10mv 100mv 1mv 10mv 100mv 0.2ua 2ua 20ua 200ua 2ma · (0.8% + 2dgts) · (1.0% + 2dgts) · (1.2% + 3dgts) (40h ¡g~ 500h ¡) · (1.0% + 2dgts) · (1.5% + 2dgts) · (2.0% + 3d...

  • Page 20

    16 ac current resistance continuity rated fuse 400 ˟ 4 ༮ 40 ༮ 400 ༮ 4 ༯ 40 ༯ 0.2uv 2uv 20uv 200uv 2mv 0.1 ˟ 1 ˟ 10 ˟ 100 ˟ 1 ༮ 10 ༮ · (1.5% + 5dgts) (40hz ~ 500hz) 40hz ~ 500hz · (1.8% + 5dgts) (40hz ~ 500hz) 40hz ~ 500hz · (3.0% + 4dgts) 40hz ~ 500hz · (1.0% + 4dgts) · (1.0% + 2dgts) · (2.0% + 4dgt...

  • Page 21

    4 . Functional use 17 ඝ power on/off the power slide switch is located on the side of rapport337. Turn the power slide switch on, and press to start the rappor337. To turn off the system, press more than 3 sec. Then, power off is displayed on the main screen with a beep. Release the button. The powe...

  • Page 22

    18 ඝ mode setup lcd screen is changed in order of video 㲯 meter 㲯 ptz 㲯 utp whenever key is pressed once. Mode select window displays on lcd screen when key is pressed more than 3 sec. Press key after selecting the mode you want, using the shift setup key. Video tester mode : at this mode, the image...

  • Page 23

    4 . Functional use 19 view information mode : at this mode, the basic information of rapport337 can be seen. (version, battery residual, communications protocol, & speed.) main setting mode : at this mode, the basic setup of rapport337 can be changed. (user's name, auto power off time, beeper, brigh...

  • Page 24

    20 osd screen setup video : indicates that the system is in video test mode. Ntsc : indicates if input or output video signal system is ntsc or pal. Input video signal is output on lcd screen by automatic checking without a special setup key, and output video signal system in pattern generator mode ...

  • Page 25

    4 . Functional use 21 enter the pattern generation mode when key is pressed in video mode. Output video system is changed to ntsc or pal, using or key. Output pattern can be seen color bar, red, blue, green or its reverse order, using or key. Press key as pattern generation mode returns to video mod...

  • Page 26

    22 ඝ digital multi meter voltage, current, resistance, continuity can be tested. W a r n i n g to prevent an electric shock, injury or damage to rapport337, cut off the power supply of the circuit, and discharge all the high-voltage capacity before testing resistance and continuity. When applying th...

  • Page 27

    4 . Functional use 23 description of meter mode lcd window part ྙ ྚ ྛ ྜ ྜྷ function kinds of test to set up test value to display measured value graph measured value in hold mode display description - resistance test - continuity test - set up tests of dc/ac voltage, current - ˟ unit of resistance te...

  • Page 28

    24 measuring resistance the unit of resistance is ˟ . The meter sends low current into the circuit so that resistance can be measured. This current runs all the paths between probes, and the measured resistance value is all values added among them. Part ྞ function dc ac ohm volt amp description dc v...

  • Page 29

    㯲testing continuity continuity means the presence of a complete path for current to flow. And the continuity test features a beep that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display. How to test : the resistance mode returns to...

  • Page 30

    26 measuring ac & dc voltage voltage means the difference in electrical potential between two points. The polarity of ac voltage varies over time, while the polarity of dc is constant over time. The meter displays ac voltage values as rms (root mean square readings. The rms value means the equivalen...

  • Page 31

    Measuring ac & dc current how to measure : first, turn off the power of the circuit, and, discharge the high voltage capacitor. Fix the red lead into the terminals of ma and 10a in accordance with the value to be measured. Select one of the buttons & . When & are selected, place the red lead on ma, ...

  • Page 32

    28 w a r n i n g check for the location of the test lead set at current test mode. Place the red lead at ma only for below 400ma, and place it at 10a when the value to be tested is over 400ma, or the value is unknown. W a r n i n g use it only for the current measuring after checking for the test mo...

  • Page 33

    4 . Functional use 29 ඝ ptz controller how to connect each terminal and lcd screen ptz operation test : the basic operation of ptz : up, down, left, right, and zoom, and manual focus controlling are possible, also. The test of various protocols and transmission speed are possible. In order to contro...

  • Page 34

    30 - key board control code screen when you want to know the input signal of an exterior controller, you can see the input data by connecting the communications cable to the rx terminal of the rapport 337. 㯲how to control ptz ptz functions (controlling up, down, left, right), etc. Are possible to be...

  • Page 35

    4 4 . Functional use 31 spst : it memorizes preset. Setup can range from 1 up to 99. (short for set preset). First, move the camera to the view to be designated , and press key, and using & keys, place the cursor at the location of spst. Then, set up the address that you want to memorize by using & ...

  • Page 36

    32 control setup of ptz ptz addr is activated on the upper part on lcd screen, when key is pressed more than 3 sec, and, the activated menu can be changed to rotocol , baudrate by pressing & keys. Ptz addr : setup of ptz id. The initial setup is made 001, and changing id of ptz is done by pressing &...

  • Page 37

    4 . Functional use 33 * baudrate : setup of transmission speed the initial setup is 2.4kbps, it can be made up to 2.4kbps ~ 38.4kbps. It is done by pressing & keys. To escape from ptz control setup mode, simply, press the key again. C a u t i o n make sure to check for camera id, protocol, baudrate ...

  • Page 38

    34 ඝ utp cable tester 㯲 connect utp cable to be tested to utp port of rapport337, while connect the other end to utp tester. The connected condition of the cable can be checked, by pressing key, after the connection is completed. Direct cable and cross cable can be classified, and disconnection or s...

  • Page 39

    4 . Functional use 35 ඝ view information mode setup : first, press key more than 3 sec. And select view information on mode select menu, then press key. ඝ main setting mode setup : first, press key more than 3 sec. And select main setting on mode select menu, then press key. Select the item by press...