Wood Stone BISTRO 4343 WS-BL-4343-RFG-LR-LP Installation And Operation Manual

Summary of BISTRO 4343 WS-BL-4343-RFG-LR-LP

  • Page 1

    Bistro line gas-fired stone hearth oven commercial dual burner model bistro 4343 ws-bl-4343-rfg-lr-(ng, lp) bistro 4355 ws-bl-4355-rfg-lr-(ng, lp) bistro 4836 ws-bl-4836-rfg-lr-(ng, lp) custom model cs-rec-9-rfg-lr-(ng, lp) custom model cs-rec-11-rfg-lr-(ng, lp) installation and operation manual woo...

  • Page 2

    2 an ongoing program of product improvement may require us to change specifications without notice. Ws-bl-rfg-lr, revised october 2014. Doc no: m0028.01 info@woodstone-corp.Com or visit woodstone-corp.Com wood stone corporation 1801 w. Bakerview rd. Bellingham, wa 98226 usa tf. 800.988.8103 t. 360.6...

  • Page 3

    3 installation and operation manual for the wood stone dual burner bistro natural gas or propane fueled dual burner stone hearth oven ws-bl-4343-rfg-lr-(ng or lp) ws-bl-4355-rfg-lr-(ng or lp) ws-bl-4836-rfg-lr-(ng or lp) cs-rec-9-rfg-lr-(ng or lp) cs-rec-11-rfg-lr-(ng or lp) additional copies availa...

  • Page 4

    4 warning: this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Important: consult your local gas supplier for a statement outlining a procedure to be followed in the event you smell gas. Post the statement in a prominent locatio...

  • Page 5

    5 save the instructions for your safety: do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Pour votre sÉcuritÉ: ne pas entreposer ni utiliser d’essence ou d’autres vapeurs de liquides inflammables ou des liquides dans les environs de ce...

  • Page 6

    6 utilities specifications gas: 3/4 inch fnpt gas inlet 105,000 btu/hr natural gas (ng) or 100,000 btu/hr propane (lp) maximum gas inlet pressure 1/2 psi (14 inches wc) side view rear view plan view rev: legend: part #: ws-bl-4355 shown bl-rfg-lr (pita oven) - all sizes general arrangement 5/30/2013...

  • Page 7

    7 side view rear view plan view rev: legend: part #: ws-bl-4355 shown bl-rfg-lr (pita oven) - all sizes general arrangement 5/30/2013 bena 1 dwn by: sheet: bellingham, wa 360/650-1111 www.Woodstone-corp.Com dimensions are in inches tolerances: linear ±1/2 [±10mm], angular ±2° unless noted otherwise ...

  • Page 8

    8 utilities specifications gas: 3/4 inch fnpt gas inlet 105,000 btu/hr natural gas (ng) or 100,000 btu/hr propane (lp) maximum gas inlet pressure 1/2 psi (14 inches wc) side view rear view plan view rev: legend: part #: ws-bl-4355 shown bl-rfg-lr (pita oven) - all sizes general arrangement 5/30/2013...

  • Page 9

    9 the oven can be moved over a flat surface with a pallet jack using the lower forklift pockets if the oven is to be installed against a wall, you may need to leave access to the back of the oven to complete the utility connections placing the oven the oven must be installed on a flat level surface ...

  • Page 10

    10 clearances 1. The wood stone bistro oven should have a minimum 1-inch clearance to combustibles from all sides, 6-inch clearance to combustibles from the top, and 6-inch clearance from the exhaust transition and flue collar. Any facade wall built 6 inches to either side of the doorway and above m...

  • Page 11

    11 flue collar wood stone ovens should be vented in accordance with nfpa 96 and/or all pertinent national, regional and local codes concerning such appliances. Check venting plans with the authority having jurisdiction before proceeding with installation. All of the combustion products and cooking v...

  • Page 12

    12 an ongoing program of product improvement may require us to change specifications without notice. Ws-bl-rfg-lr, revised october 2014. Doc no: m0028.01 info@woodstone-corp.Com or visit woodstone-corp.Com wood stone corporation 1801 w. Bakerview rd. Bellingham, wa 98226 usa tf. 800.988.8103 t. 360....

  • Page 13

    13 make utility connections at the rear of the control box gas and electrical connections must comply with all relevant national and local codes, and in a manner acceptable to the authority having jurisdiction knockouts are provided on the sides of the oven stand for the incoming gas and electrical ...

  • Page 14

    14 the installation must conform with local codes, or in the absence of local codes with the national fuel gas code, ansi 223.1 or natural gas installation code, can/cga-b149.1, as applicable. 1. The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas su...

  • Page 15

    15 an ongoing program of product improvement may require us to change specifications without notice. Ws-bl-rfg-lr, revised october 2014. Doc no: m0028.01 info@woodstone-corp.Com or visit woodstone-corp.Com wood stone corporation 1801 w. Bakerview rd. Bellingham, wa 98226 usa tf. 800.988.8103 t. 360....

  • Page 16

    16 flame height control knob (left) use these knobs to raise/lower the flame to control the oven temperature dual burner models have (2) knobs which are linked together (see burner disable switch at right) flame height control knob (right) burner disable switch use this switch to disable one of the ...

  • Page 17

    17 initial oven start-up for dual burner bistro models first day 1. Make sure main gas supply is on (valve parallel with gas line) 2. Push i/o button on controller it may take a while for the gas to purge all the air from the gas lines (verify both burners light if only one is lite, check that the b...

  • Page 18

    18 general daily oven operation the oven floor temperature is displayed on the controller readout end of the day push i/o button on the controller all gas will go off, even the pilots when the oven is turned off, use the night heat retention door to help retain heat in the oven the night door is pla...

  • Page 19

    19 oven interior wood stone recommends the use of long-handled brushes for sweeping up surface debris that will accumulate on the floor of the oven during use use a natural fiber brush—always brushing away from the radiant burner wells for deeper cleaning, use a brass bristled brush the oven floor c...

  • Page 20

    20 please contact wood stone at 1-800-988-8103 should service be necessary, or if you have any questions about your oven. Our service hours are 8am to 4:30pm pacific standard time. Follow the recorded instructions for emergency service if you require assistance during non-business hours. A wood ston...

  • Page 21

    21 dual burner bistro - all models 120 vac electrical diagram dual rfg date: diag #: wd075 rev. 1 11/12/2014 bellingham, wa +1(360)650-1111 www.Woodstone-corp.Com radiant right junction box l n g cb 4a gnd xfmr 110-120 vac 50/60hz wired by others white brown brown blue yellow temperature controller ...

  • Page 22

    22 dual burner bistro - all models 240 vac electrical diagram dual rfg date: diag #: w d078 rev. 0 7/17/2014 bellingham, wa +1(360)650-1111 www.Woodstone-corp.Com radiant right junction box l n g fuse f1 - 5a gnd xfmr 230 - 240 vac 50/60hz wired by others w hite brown brown pink w hite temperature c...

  • Page 23

    23 120 vac oven circuit 120 vac to oven s1 is a double pole, single throw (dpst) switch provided by others. 120 vac to fan wired by others s1 120 vac fan circuit interlock of oven control to an exhaust fan this connection is intended to interrupt power to the oven until the fan is turned on s1 is a ...

  • Page 24

    24 all warranty service must be pre-approved by wood stone wood stone warrants its equipment to the original purchaser against defects in material or manufacture for a period of one year from the original date of purchase, subject to the following exclusions and limitations. Please contact the facto...