Woodstock Soapstone Fireside Franklin Installation Manual - Very Important Note:
III. Termination Clearances:
The vent pipe must terminate outside the home with
clearances adequate to protect against heat and against
exhaust re-entering the house. Below are the approved
minimum clearances for the termination cap of your
Fireside Franklin gas fireplace:
uFor vertical terminations the direct vent pipe must
extend 1.5 to 2 feet above the roof surface.
u A minimum of 12 inches must be maintained from:
; Permanently closed window (RIGHT “A”)
; Door or window that may be opened (RIGHT “B”)
; Clearance above grade (RIGHT “C”)
; Below deck, veranda, or balcony (RIGHT “C”)
; Non-mechanical air supply inlet, combustion inlet
or any other appliance inlet (RIGHT “D”)
; Inside corner or adjacent wall (RIGHT “E”)
; Non-ventilated soffit (BELOW “F”)
u A minimum of 18 inches must be maintained from:
; Deck, porch, veranda, balcony in a vertical direction
(RIGHT “G”)
; Ventilated soffit located above the termination cap
(RIGHT “H”)
u A minimum of 3 feet must be maintained from:
; Centerline of a service regulator (BELOW LEFT “I”)
; Vegetation (BELOW LEFT “J”)
Minimum Clearances: Corner Installation
22""
22""
Minimum Clearances: Parallel Installation
* 2” clearance can only be achieved with a
straight-up vertical vent configuration.
22""**
88""
G
Grraaddee
A
Aiirr
N
Noonn
M
Meecchhaanniiccaall
A
Aiirr SSuuppppllyy
G
G
D
D
H
H
EE
CC
RRooooff
D
Deecckk
A
A
EE
BB
CC
M
Meecchhaanniiccaall
A
Aiirr SSuuppppllyy
VVeeggeettaattiioonn
RRooooff
KK
II
LL
JJ
FF
BB
M
M
N
Noonnvveennttiillaatteedd
SSooffffiitt
PPuubblliicc SSiiddeew
waallkk oorr
D
Drriivveew
waayy
+
VERY IMPORTANT NOTE:
Connections Betwen Components
Simpson Dura-Vent GS system 6 5/8” venting is the
only approved system for use with your Fireside
Franklin gas fireplace. These venting systems have
an interconnection locking system built into each
vent piece allowing a safe and secure connection
without need for additional hardware or tools. It is
critical to the effective heating, proper flame pattern
and your safety to ensure that each connection is
completely secure. This is accomplished by assem-
bling the venting with the female end toward the
stove, pushing them together and twisting the piece
to be connected in a clockwise direction 1/8 of a turn
until it comes to a positive stop in the locked posi-
tion. During the initial connection, you’ll need to
ensure that the inner pipes are overlapping, as this
cannot be checked from the outside of assembled sec-
tions.
Horizontal termination caps must be positioned 12-18 inches above
grade, and 12-18 inches away from windows, decks, soffits, and non-
mechanical air supplies.
Service regulators and vents should be located away from vegetation,
driveways, sidewalks, and other high traffic areas.
u A minimum of 6 feet must be main-
tained from:
; Service regulator vent outlet
(BELOW LEFT “K”)
; Mechanical air supply (BELOW
LEFT “L”)
u A minimum of 7 feet must be main-
tained above:
; A paved driveway or sidewalk on
public property (BELOW
LEFT “M”)
Venting may NEVER terminate above a
sidewalk or driveway that is between
two single-family dwellings and services
both.