    Technical and specification information greenstar cdi classic regular series greenstar ri series greenstar regular gas-fired condensing wall mounted boiler range.

  • Page 2

    2 worcester and you. Making a difference. As part of the bosch group, worcester products are designed and manufactured to provide customers with the highest levels of quality and reliability which are synonymous with the bosch name throughout the world. As part of europe’s largest supplier of heatin...

  • Page 3

    3 “at worcester we recognise the vital role you play in the specification and installation of energy efficient appliances in homes across the uk. We will continue to invest in our products, people, facilities and added value services to ensure you have all you require in order to deliver only the be...

  • Page 4

    4 the greenstar condensing regular boiler range the greenstar regular range is part of a market leading range of energy-saving condensing wall mounted gas-fired boilers. Floor standing regular boilers are also available from worcester in 30kw and 40kw outputs. For further information see the fs cdi ...

  • Page 5

    5 the greenstar regular range at a glance 12ri 15ri 18ri 24ri 30cdi classic regular 40cdi classic regular output kw to central heating (ch) min 4kw 5kw 6kw 8kw 7.7kw 9.4kw max 12kw 15kw 18kw 24kw 30kw 40.8kw primary temperature control modulating control natural gas lpg boiler electronic ignition.

  • Page 6

    6 features of the greenstar condensing regular boiler range a condensing boiler is more efficient due to its ability to extract more heat from the flue gases normally lost to the environment through the flue system. As the flue gases pass through the heat exchanger this extra surface area can cool t...

  • Page 7

    7 *where required – see installation booklet for further details. **subject to terms and conditions. 1. Power on/off switch 2. Burner ‘on’ indicator led 3. Service mode button (greenstar cdi classic regular only) 4. Inspection and advanced service mode button (greenstar cdi classic regular only) 5. ...

  • Page 8

    8 inside story – greenstar ri condensing regular boiler series fan pressure test point air/gas manifold fan air/gas adjustment screw gas valve inlet pressure test point boiler power switch syphonic trap power and fault indicator (blue) flame indicator (green) cover for external wiring connections fl...

  • Page 9

    9 technical data model greenstar 12ri greenstar 15ri greenstar 18ri greenstar 24ri height (mm) 600 600 600 600 width (mm) 390 390 390 390 depth (mm) 270 270 270 270 weight – dry (kg) 22.6 22.6 22.6 22.6 2005 sedbuk value – natural gas 90.1% / a rated 90.1% / a rated 90.1% / a rated 90.2% / a rated 2...

  • Page 10

    Inside story – greenstar cdi classic regular condensing boiler series 10 auto air vent air/gas adjustment screw condensate syphon gas valve down firing low nox burner aluminium/ silicon wb5 heat exchanger pre-mix fan drain point digital display on/off button central heating temperature control.

  • Page 11

    11 technical data model greenstar 30cdi classic regular greenstar 40cdi classic regular height (mm) 760 (max) 760 (max) width (mm) 440 440 depth (mm) 360 (max) 360 (max) weight – dry (kg) 39.5 39.5 2005 sedbuk value – natural gas 90.3% / a rated 90.2% / a rated 2005 sedbuk value – lpg 92.3% / a rate...

  • Page 12

    12 site preparations and guidance the greenstar regular boilers are designed for connection to a traditional heating and hot water system. The major benefits are: • the boiler is compatible with s and y plan systems • the boiler comes supplied with a wall mounting bracket and a plastic bottom panel....

  • Page 13

    13 compartment installation the appliance may be installed in any room, although particular attention is drawn to the requirements of the iee regulations applicable and in scotland the electrical provisions with respect to installation in a room containing a bath or shower. 1. The room in which the ...

  • Page 14

    14 pipework connections and casing dimensions (when fitted to wall frame) depth to wall greenstar ri a c b greenstar ri 45 65 220 b a c greenstar cdi classic regular a b c a c b greenstar cdi classic regular cabinet dimensions (mm) greenstar ri a 600 b 390 c 270 greenstar cdi classic regular a 750* ...

  • Page 15

    15 600mm 600mm 2,250mm 600mm 600mm radius 750mm 750mm 2,250mm 2,250mm 1 2 2 1 1 1 2 2 2,250mm 600mm 600mm 2,250mm 600mm 600mm radius 750mm 750mm 2,250mm 2,250mm 1 2 2 1 1 1 2 2 2,250mm boiler location & clearances bathrooms important: any switch or appliance control using mains electricity must not ...

  • Page 16

    Important points to consider when siting a condensate drainage pipe: • where a new or replacement boiler is being installed, access to an internal “gravity discharge” point should be one of the factors considered in determining boiler location • the condensate pipe must be a minimum of 22mm dia. Pla...

  • Page 17

    Pipework transition 500mm min. 25mm min. 400mm min. Siphon trap bottom of sealed tube limestone chippings 100mm dia. Min. Plastic pipe 25mm min. External rain water pipe into foul water external air break air gap 25mm min. Insulate & increase pipe size condensate pump external options 100mm dia. Sip...

  • Page 18: New

    18 with climate change and extreme weather variations becoming increasingly common, and very cold winters with temperatures as low as -20°c being experienced, practices such as externally run condensate discharge pipework are now being questioned. The condensesure auxiliary siphon has been designed ...

  • Page 19

    19 fitting to a regular boiler ease of installation the condensesure has been designed for ease of installation in mind and is suitable for most boiler applications. For maximum effectiveness it should be installed immediately beneath the boiler where it is clipped on to the boiler’s heating flow pi...

  • Page 20

    20 installation requirements installation of the greenstar regular boiler range must be in accordance with the relevant requirements of the gas safety (installation use) regulations (as amended), current iee wiring regulations, local building regulations, building standards (scotland) regulations an...

  • Page 21

    21 open vented primary systems the greenstar regular boiler range is designed for connection to an open vented fully pumped heating and hot water system. The following points are for guidance only. The system installation should be carried out in accordance with bs 5449:part 1. The cistern must be a...

  • Page 22

    22 liquid petroleum gas (lpg) supply the greenstar ri regular appliance is available in an lpg version. The appliance, when on demand at full output will require 0.5m 3 /h, 0.96kg/h, (17.7ft 3 /hr) for the 12ri, 0.63m 3 /h, 1.20kg/h, (22.25ft 3 /hr) for the 15ri, 0.76m 3 /h, 1.44kg/h, (26.70ft 3 /hr...

  • Page 23: New

    23 the worcester greenstar system filter modern condensing boilers are precision engineered and designed to run with a clean water heating system. Over time, dirty system water will damage a boiler and its components, causing failures and shortening the life of the overall system. Damaged boiler and...

  • Page 24

    24 horizontal and vertical flue terminal positioning 16 600 300 200 300 1,200 boundary line 1,500 1,500 2 1 12 11 10 9 5 18 7 6 13 15 4 3 17 14 300 300 300 300 300 300 300 500 600 300 600 600 400 300 25 8 300 500 600 300 25 2 25 16 2m 1m 52mm 104mm note • all measurements are the minimum clearances ...

  • Page 25

    25 horizontal and vertical flue terminal positioning 16 600 300 200 300 1,200 boundary line 1,500 1,500 2 1 12 11 10 9 5 18 7 6 13 15 4 3 17 14 300 300 300 300 300 300 300 500 600 300 600 600 400 300 25 8 300 500 600 300 25 2 25 16 2m 1m 52mm 104mm 9. 300mm above, below and either side of an opening...

  • Page 26

    26 greenstar regular boiler range horizontal fluing options the greenstar regular boiler range have the choice of 2 differently sized horizontal rsf flue systems, a 100mm diameter telescopic flue kit including a plume management kit and a 125mm diameter telescopic flue kit. Both systems have differe...

  • Page 27

    27 option 1 standard horizontal flue assembly maximum components required length (mm) greenstar ri series 100mm 570 1 125mm 600 1 greenstar 30cdi classic regular 100mm 570 1 125mm 600 1 greenstar 40cdi classic regular 100mm 570 1 125mm 600 1 option 2 extension flue horizontal option 3 extension flue...

  • Page 28

    28 option 6 extension flue upwards and horizontal using a third 90º bend maximum components required length (mm) greenstar ri series 125mm 9,000 1 up to 9 3 1 greenstar 30cdi classic regular 100mm 4,900 1 up to 5 3 1 125mm 14,500 1 up to 14 3 1 greenstar 40cdi classic regular 100mm 3,000 1 up to 2 3...

  • Page 29

    29 greenstar regular boiler range vertical fluing options the greenstar regular boiler range have the choice of 2 differently sized vertical rsf flue systems, 100mm and 125mm. Both systems have different maximum lengths. Options 1 to 4 detail the permissible lengths. Vertical rsf flue vertical balan...

  • Page 30

    30 option 2 vertical balanced flue system maximum height 300mm 500mm flat roof pitched roof 300mm 500mm pitched roof flat roof 100mm dia. 1,090mm 125mm dia. 1,365mm l = maximum components required length (mm) greenstar ri series 100mm 6,400 1 up to 6 125mm 15,000 1 up to 14 greenstar 30cdi classic r...

  • Page 31

    31 plume management terminal positioning 200 300 150 200 8 4 5 3 2 9 200 600 300 300 150 150 300 300 25 25 150 1,200 300 200 10 100 600 plume re-direction: 180° ±80° 1 7 ±45° flue exhaust outlet air intake 6 10 boundary line 150 300 300 flue terminal guard 7 716 191 176 600 1,500 all measurements in...

  • Page 32

    32 greenstar regular boiler range plume management system options standard plume management system the flue terminal outlet has built-in stops to limit rotation for horizontal fluing to allow condensate to run back into the boiler for safe disposal. Do not attempt to force beyond the limit stops. Al...

  • Page 33

    33 greenstar ri regular boilers are able to use the maximum 100mm dia. Internal flue length of 4,600mm regardless of the amount of plume management selected. External plume management bends still need to be allowed for. See below. For greenstar cdi classic regular boilers the 100mm dia. Internal flu...

  • Page 34

    34 option 1 plume management system minimum components required length (mm) greenstar ri series 60mm 500 1 greenstar cdi classic regular series 60mm 500* 1 option 2 plume management system with extensions maximum components required length (mm) greenstar ri series 60mm 4,500 1 up to 4 greenstar cdi ...

  • Page 35

    35 option 5 plume management system with extensions and 45º bends maximum components required length (mm) greenstar ri series 60mm 3,000 1 up to 3 2 greenstar cdi classic regular series 60mm 3,000* 1 up to 3 2 *note: you must refer to the table and graph on page 33 to calculate your horizontal flue ...

  • Page 36

    36 vertical bf kit (100mm dia.) worcester part no. 7 719 002 430 greenstar regular boiler range accessories vertical bf kit (125mm dia.) worcester part no. 7 719 002 431 1,000mm extension (125mm dia.) worcester part no. 7 719 003 666 short flue extension 220mm (100mm dia.) worcester part no. 7 716 1...

  • Page 37

    Below boiler pipe cover worcester part no. 7 716 192 608 37 plume management kit (60mm dia.) worcester part no. 7 716 191 086 extension (60mm dia., 1,000mm) worcester part no. 7 716 191 087 90º bend (60mm dia.) worcester part no. 7 716 191 088 45º bend (60mm dia.) worcester part no. 7 716 191 089 fl...

  • Page 38

    38 whether you are upgrading an existing system or installing a new system, worcester greenfloor heating can provide an ideal alternative to traditional radiators. Worcester’s greenfloor heating system uses a water-filled pipe system that turns the floor into a large surface area radiator. The pipe ...

  • Page 39

    39 belfast wakefield clay cross worcester west thurrock dundee dublin burnley durham wiltshire tredegar cambridge wrexham camborne johnstone borders elgin w w w w w w w w w w w w w w w w w w w the total training experience worcester expertise that will build your skills worcester has always placed g...

  • Page 40

    Gas-fired product courses as a market leader in gas-fired condensing boilers, we aim to ensure the highest levels of competence and expertise in the installation of all worcester gas-fired products. We run intensive training courses for installers, commissioning engineers and operatives involved wit...

  • Page 41

    Additional product and industry training courses the diversity of products in today’s heating industry gives you the opportunity to expand your expertise, whilst offering more choice to your customers. Worcester provides comprehensive training from all its academies on its entire range of technologi...

  • Page 42

    42 a complete after-sales service all the technical advice you need spares genuine replacement parts for all supported worcester products are readily available from stock, or on a next day delivery basis. Visit our website at www.Worcester-bosch. Co.Uk/spares to find your local stockist. Customer te...

  • Page 43

    43 notes.

  • Page 44

    Www.Worcester-bosch.Co.Uk worcester, bosch group is a brand name of bosch thermotechnology ltd. This leaflet is accurate at the date of printing, but may be superseded and should be disregarded if specification and/or appearances are changed in the interest of continued improvement. The statutory ri...