Worcester Greenstar Comfort I RF Installation And Operating Instructions Manual

Manual is about: Radio Frequency Twin Channel Programmer/Receiver and Room Thermostat

Summary of Greenstar Comfort I RF

  • Page 1

    Uk/ie installation and operating instructions radio frequency twin channel programmer/receiver and room thermostat greenstar comfort i rf 6720810964-00.1wo select advance select advance menu for ems compatible worcester greenstar condensing boilers 6 720 8 10 964 (2014/07).

  • Page 2

    2 contents comfort i – 6720810964 (2014/07) contents 1 key to symbols and safety instructions . . . . . . . . . . . 3 1.1 key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 general safety instructions . . . . . . . . . . . . . . . . . . 3 2 comfort i rf . . . . . . . . . . ...

  • Page 3

    3 key to symbols and safety instructions comfort i– 6720810964 (2014/07) 1 key to symbols and safety instructions 1.1 key to symbols warnings the following keywords are defined and can be used in this document: • notice indicates a situation that could result in damage to property or equipment. • ca...

  • Page 4

    4 comfort i rf comfort i – 6720810964 (2014/07) 2 comfort i rf the comfort i rf comprises a boiler or wall mounted twin channel programmer/receiver and wall mounted room thermostat. 2.1 programmer/receiver the boiler fascia mounted unit is a twin channel programmer/receiver and is connected to an rf...

  • Page 5

    5 comfort i rf comfort i– 6720810964 (2014/07) 2.2 rf room thermostat the room thermostat can only be used in conjunction with the programmer/receiver. The room thermostat displays the current room temperature and is also used to set a new temperature set point. This information is transmitted back ...

  • Page 6

    6 installation comfort i – 6720810964 (2014/07) 3 installation refer to the boiler’s installation, commissioning and servicing instruction manual for information on the boiler. Refer to this manual for detailed information on installing and using the comfort i rf. A brief overview of the comfort i r...

  • Page 7

    7 installation comfort i– 6720810964 (2014/07) fig. 3 suggested programmer wall plate mounting ▶ engage the four clips on the back of the programmer [2] with the four slots on the wall plate as shown in figure 4 ▶ push the programmer down into the wall plate to secure ▶ engage the tabs on the top re...

  • Page 8

    8 installation comfort i – 6720810964 (2014/07) ▶ turn the knob to select radio settings ▶ press the knob to display pairing, that is rf pairing of the devices in the system ▶ turn the knob to display unpairing or pairing ▶ if pairing is chosen, press the knob and pairing is displayed with advancing...

  • Page 9

    9 installation comfort i– 6720810964 (2014/07) the thermostat must not be directly influenced by radiators or other appliances giving off heat, such as televisions or table lamps. Fig. 6 device location wall mounting plate to remove the wall mounting plate: 1. Insert a suitable flat bladed screwdriv...

  • Page 10

    10 operation comfort i – 6720810964 (2014/07) 4 operation the programmer/receiver is supplied with factory set default on and off times, for central heating (ch) and hot water (hw), that are shown in the table below. These time settings can be reset according to the homeowner’s requirements via the ...

  • Page 11

    11 programmer/receiver settings comfort i– 6720810964 (2014/07) 5 programmer/receiver settings there are two levels of settings: 1. User 2. Installer 5.1 user press the menu button for more than three seconds to enter the user setting area of the programmer/receiver. Five icons are shown across the ...

  • Page 12

    12 programmer/receiver settings comfort i – 6720810964 (2014/07) 5.1.2 hot water this time program is used to set your required on and off times for the hot water. The programmer has default time settings as shown below: time programs select time program with the knob, and press to enter. In the tim...

  • Page 13

    13 programmer/receiver settings comfort i– 6720810964 (2014/07) ▶ turn the knob to select on or off, if on is selected the programmer will automatically adjust the time in conjunction with daylight savings time ▶ press the knob to confirm the selection ▶ press the return button to go back to time/da...

  • Page 14

    14 programmer/receiver settings comfort i – 6720810964 (2014/07) 5.2 installer these functions are only used by the installer/service engineer and are useful during installation. Press the menu button and return button for more than three seconds to enter the installer setting area of the programmer...

  • Page 15

    15 programmer/receiver settings comfort i– 6720810964 (2014/07) when the devices are being paired, the room thermostat and programmer/receiver must be in the same mode of pairing. Refer to section 6.5 for pairing of the room thermostat. Ensure that the room thermostat is positioned as suggested in s...

  • Page 16

    16 room thermostat comfort i – 6720810964 (2014/07) 6 room thermostat 6.1 normal operation under normal operation the display shows the current room temperature in centigrade. Fig. 15 normal screen 1. Current room temperature 2. Battery condition indicator 3. Burner on indicator press the knob brief...

  • Page 17

    17 room thermostat comfort i– 6720810964 (2014/07) 6.2 settings these functions are only used by the installer/service engineer and are useful during installation. To enter the settings menu: 1. Press the knob until two bars are displayed. 2. Release the knob to enter the settings menu fig. 18 enter...

  • Page 18

    18 room thermostat comfort i – 6720810964 (2014/07) 6.5 rf 1 pair with other devices ▶ turn the knob to select rf 1 and press to enter the function ▶ to pair the devices, turn the knob to select a, pair this programmer with the room thermostat ▶ press the knob to start the pairing process, the timer...

  • Page 19

    19 troubleshooting comfort i– 6720810964 (2014/07) 7 troubleshooting 7.1 temperature related faults 7.2 room thermostat/programmer related faults 7.2.1 room thermostat faults are displayed alternating with the current room temperature. 7.2.2 programmer/receiver faults will be display alternating bet...

  • Page 20

    20 servicing comfort i – 6720810964 (2014/07) 8 servicing these units can not be serviced. Should either unit fail to function correctly check that the: ▶ programmer/receiver settings are correct ▶ rf signal link between the units is set up correctly, sections 6.5 and page 14 radio settings ▶ room t...

  • Page 21

    21 erp class comfort i– 6720810964 (2014/07) 10 erp class the data represented in the table below is required for the completion of energy related product (erp) directive system package fiche and, subsequently, the erp system data label. Erp labelling obligation applicable from 26th september 2015. ...

  • Page 22

    22 comfort i – 6720810964 (2014/07) notes.

  • Page 23

    23 comfort i– 6720810964 (2014/07) notes.

  • Page 24

    Worcester, bosch group: technical support: 0330 123 3366 appointments: 0330 123 9339 spares: 0330 123 9779 literature: 0330 123 9119 training: 0330 123 0166 sales: 0330 123 9669 worcester, bosch group cotswold way, warndon, worcester wr4 9sw. Tel. 0330 123 9559 worcester, bosch group is a brand name...