    Uk user instructions floor standing oil fired condensing boiler conventional flue and room sealed flue greenstar danesmoor utility erp 32/50 & 50/70 6 720 813 330-01.1tl for fully pumped open vent and sealed central heating systems and domestic hot water cylinders. For use with kerosene (class c2) o...

  • Page 2

    2 preface greenstar danesmoor utility erp – 6 720 813 330 (2014/09) preface please read these instructions carefully these instructions are applicable to the worcester, bosch group appliance model stated on the front cover only. These instructions apply in the uk only and must be followed except for...

  • Page 3

    3 key to symbols and safety instructions greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 1 key to symbols and safety instructions 1.1 key to symbols warnings the following keywords are defined and can be used in this document: • notice indicates a situation that could result in damage to p...

  • Page 4

    4 general information greenstar danesmoor utility erp – 6 720 813 330 (2014/09) combustion air/room air the air in the installation room must be free of combustible or chemically aggressive substances. ▶ do not use or store combustible or explosive materials (paper, propellants, thinners, paints, et...

  • Page 5

    5 using your boiler greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 3 using your boiler 3.1 controls fig. 1 [a] temperature control (behind upper front panel) [b] reset button - boiler overheat thermostat (behind front panel) [c] reset button - flue overheat thermostat (behind front panel)...

  • Page 6

    6 maintenance greenstar danesmoor utility erp – 6 720 813 330 (2014/09) ▶ turn the room thermostat to the temperature required. ▶ set thermostatic radiator valves to the required temperature for each room. 3.2.4 frost protection ▶ frost thermostats can be wired into the boiler. ▶ frost protection sh...

  • Page 7: Annual

    7 general information greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 5 general information 5.1 ventilation information boiler location **the boiler can be installed under a work top as long as: ▶ the work top above the boiler is easily removable for maintenance. ▶ there is at least 10mm c...

  • Page 8

    8 general information greenstar danesmoor utility erp – 6 720 813 330 (2014/09) venting compartments ▶ ventilation must be provided for boilers fitted into compartments as described in bs 5410 ▶ a minimum of two air vents must be fitted, one at low level and another at high level onto the same wall ...

  • Page 9

    9 fault finding greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 6 fault finding in the event that the appliance stops functioning or does not perform as expected, you can carry out a few simple checks. These checks are some of the most common causes and are listed in the table below. Shoul...

  • Page 10

    10 fault finding greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 6.1 accessing reset buttons reset buttons [a, b & c] ▶ to remove upper front panel pull panel squarely away from the front of the boiler. ▶ to replace, realign ball studs and push back into place. Burner lockout reset button ...

  • Page 11

    11 fault or breakdown greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 7 fault or breakdown this boiler is supported in mainland uk by worcester, bosch group, part of bosch thermotechnology ltd. Specialist service engineers are available to attend a breakdown occurring on this appliance. • ...

  • Page 12

    12 energy saving greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 8 energy saving 8.1 tips on energy saving room thermostats reducing the setting of the room thermostat by 1°c can reduce fuel consumption by up to 10%. New control systems upgrade your heating control system with the latest e...

  • Page 13

    13 your guarantee greenstar danesmoor utility erp – 6 720 813 330 (2014/09) 10 your guarantee 10.1 guarantee registration you should complete and return the postpaid guarantee registration card within 30 days of installation. Returning your card will register you as the owner of your new boiler and ...

  • Page 14

    14 greenstar danesmoor utility erp – 6 720 813 330 (2014/09) notes.

  • Page 15

    15 greenstar danesmoor utility erp – 6 720 813 330 (2014/09) notes.

  • Page 16

    Worcester, bosch group: technical support: 0330 123 3366 appointments: 0330 123 9339 spares: 0330 123 9779 literature: 0330 123 9119 training: 0330 123 0166 sales: 0330 123 9669 worcester, bosch group cotswold way, warndon, worcester wr4 9sw. Tel. 0330 123 9559 worcester, bosch group is a brand name...