Worcester Greenstar Heatslave 12/18 Technical Information

Other manuals for Greenstar Heatslave 12/18: Instruction Manual
Manual is about: FLOOR STANDING OIL FIRED CONDENSING COMBINATION BOILER

Summary of Greenstar Heatslave 12/18

  • Page 1

    1 the greenstar heatslave range of high efficiency oil-fired condensing combi boilers from worcester technical and specification information 2007 oftec ‘national training centre of the year’ & ‘regional training centre of the year’ award winners.

  • Page 2

    3 2 worcester and you. Making a difference. Contents page the greenstar heatslave oil-fired condensing 4 - 7 combi boiler series the inside story 8 - 9 technical data 10 installing the greenstar heatslave series 11 - 17 greenstar heatslave series horizontal 18 - 19 fluing options (kitchen models) gr...

  • Page 3

    5 4 the greenstar heatslave oil-fired condensing combi boiler series the greenstar heatslave range at a glance 12/18 18/25 25/32 condensing / sedbuk a rated • • • output kw dhw flow rate 15l/min** 18l/min* 22l/min* floor standing • • • dimensions (mm) (w x h x d) 520 x 855 x 600 520 x 855 x 600 520 ...

  • Page 4

    7 6 models the greenstar heatslave is supplied as standard suitable for sealed primary water systems. The appliance contains an expansion vessel, 3bar pressure relief valve, pressure gauge and an automatic air vent. The appliance can be connected to an open vent or sealed primary system. Options oil...

  • Page 5

    9 the greenstar heatslave oil-fired condensing combi boiler – inside story (kitchen models) key to components 1. Overheat thermostat reset button 2. Electrical control box assembly 3. Pressure jet burner 4. Primary heat exchanger 5. Heat bank drain-off tap 6. Heat bank 7. Circulating pump 8. Diverte...

  • Page 6

    11 10 technical data – greenstar heatslave series model greenstar heatslave greenstar heatslave greenstar heatslave 12/18 18/25 25/32 primary water capacity (total) (litres) 69 69 72 maximum static head (metres) 30 30 30 minimum static head (metres) 1 1 1 exit flue gas mass flow (kg/hr) 29 40 51 con...

  • Page 7

    13 12 installation general the appliance should not be installed where there is a potential for excessive ground water coverage. The appliance is only suitable for installing externally at a suitable location onto a fixed, permanent rigid surface. There must be sufficient hard standing around the ap...

  • Page 8

    15 14 pump output greenstar heatslave 12/18kw and 18/25kw models greenstar heatslave 25/32kw model condensate disposal all condensing boilers generate condensate discharge which needs to be piped away from the appliance in a plastic pipe. The amount of condensate generated depends on the efficiency ...

  • Page 9

    17 16 compartment clearances (kitchen models) follow the requirements of bs5410 and note: • minimum clearances must be maintained. • an access door is required to install, service and maintain the boiler and any ancillary equipment. • if fitting the boiler into an airing cupboard use a non- combusti...

  • Page 10

    19 18 greenstar heatslave series horizontal fluing options (kitchen models) horizontal rs flue standard flue kit comprises: 1 x terminal assembly 1 x internal finishing plate(s) 1 x external weather seal 1 x flue clamp part no. 7 716 190 031 accessories the following criteria should be noted when pl...

  • Page 11

    21 20 greenstar heatslave series vertical fluing options (kitchen models) vertical rs flue vertical balanced flue kit comprises: 1 x flue terminal assembly 1 x fire stop plates 1 x wall clip 1 x flue clamp 1 x bend part no. 7 716 190 032 accessories flue diameter 125mm flue terminal assembly diamete...

  • Page 12

    23 22 horizontal rs flue low level horizontal bf kit comprises: 1 x terminal assembly part no. 7 716 190 052 accessories worcester part no. 125mm dia. 90º bend 7 716 190 034 flue terminal guard 7 716 190 050 greenstar heatslave series horizontal fluing options (external models) option 1 low-level re...

  • Page 13

    25 24 calculating the length: l maximum = boiler maximum minus 1m*. (each 45º bend has a 0.5m equivalent flue length) *if the chimney has an additional offset, then l will be reduced by an extra metre. **the top 45º bend may not be required if there is sufficient room in the chimney to turn the flex...

  • Page 14

    80/125mm dia. Horizontal external flue kit – comprises: 1 x terminal assembly 1 x 80/125 weather seal 1 x external bend 1 x external cabinet flue seal and plate 1 x clamp bracket 1 x drill pack part no. 7 716 190 057 accessories worcester part no. 80/125mm dia. 100/150mm dia. External flue extension...

  • Page 15

    Option 1 top outlet maximum total straight flue length 80/125mm dia. 100/150mm dia. Heatslave 5,000mm – heatslave external** – – flue components required flue diameter description quantity worcester part no. Greenstar heatslave 125mm vertical external flue kit 1 7 716 190 053 125mm external flue ext...

  • Page 16

    31 30 plastic pipework plastic pipework must have a polymeric barrier. Underfloor heating • plastic pipework used for underfloor heating must be correctly controlled with a thermostatic blending valve limiting the temperature of the circuits to approx. 50ºc. The pipework from the boiler to the blend...

  • Page 17

    33 32 external tank installations building regulations – england and wales in england and wales installations in single family dwellings must comply with building regulations part j. This in turn requires compliance with bs 5410 : part 1 : 1997 and part 2 : 1998. All tanks deemed to be at risk or wi...

  • Page 18

    35 34 for more information refer to bs 5410 : part 1 : 1997, oftec book three and technical sheet t1/131. 300 mm can be less than 760mm clearance 300mm non combustible boundary (note 5) non combustible base (note 2) non combustible wall of building with opening (note 7) oil tank min. 1.8m opening at...

  • Page 19

    37 36 table 2 double pipe sub-gravity feed system table 3 single pipe suction lift with de-aerator oil filters oil filters must always be incorporated in the oil supply line, one on the outlet from the oil tank to filter deposits from within the tank or fuel and one near the appliance to filter depo...

  • Page 20

    39 38 telescopic extension worcester part no. 100mm dia. 7 716 190 068 130mm dia. 7 716 190 072 45º bend worcester part no. 100mm dia. 7 716 190 069 130mm dia. 7 716 190 073 wall cover plate kit worcester part no. 100mm dia. Flue 7 716 190 074 130mm dia. Flue 7 716 190 075 horizontal external flue k...

  • Page 21

    A complete after-sales service all the technical advice you need spares genuine replacement parts for all worcester boilers are readily available from stock, on a next day delivery basis. For more information please call your local stockist. You can find a spares stockist on our website. Customer te...

  • Page 22

    Worcester training courses worcester training courses greenstar cdi and highflow cdi gas-fired condensing combi boilers models covered greenstar 27/30/37/42cdi greenstar highflow 440/550cdi duration 1 day greenstar i junior and si gas-fired condensing combi boilers models covered greenstar 24/28i ju...

  • Page 23

    Www.Worcester-bosch.Co.Uk in partnership with worcester, bosch group is a brand name of bosch thermotechnology ltd. This leaflet is accurate at the date of printing, but may be superseded and should be disregarded if specification and/or appearances are changed in the interest of continued improveme...