Worcester RT 10 Installation, User Instructions & Customer Care Manual

Summary of RT 10

  • Page 1

    Installation and operating instructions room temperature controller for heating appliances with bus-enabled heatronic 3 and td 200 rt 10 6 720 612 218-00.1r order no. 7 719 002 505 6 720 612 218 gb (05.09) osw installation, user instructions & customer care guide 6 7 20 6 12 2 18- 0 0. 1r rt 10 room...

  • Page 2: Dear Customer,

    2 6 720 612 218 gb (05.09) dear customer, congratulations on having decided in favour of a top-quality product from our company. The rt 10 offers everything you can expect from a modern heating control: it is both reliable and energy saving. Like all bosch group products, the rt 10 has been produced...

  • Page 3: Contents

    3 contents 6 720 612 218 gb (05.09) contents safety precautions 4 symbols 4 1 technical data for the accessory item 5 1.1 standard package 5 1.2 technical data 5 1.3 accessories 5 1.4 description of function 6 2 installation 7 2.1 assembly 7 2.2 electrical connections 9 3 operation 10 3.1 change req...

  • Page 4: Safety Precautions

    4 safety precautions 6 720 612 218 gb (05.09) safety precautions b these instructions must be observed to ensure correct opera- tion. B the accessories should be installed by an authorised heating installer only. B only use these accessories in con- junction with the heating appliances listed. Obser...

  • Page 5: Technical Data

    5 technical data for the accessory item 6 720 612 218 gb (05.09) 1 technical data for the accessory item the rt 10 allows the control of the room temperature of an unmixed heat- ing circuit. 1.1 standard package room temperature controller rt 10 1.2 technical data 1.3 accessories text display td 200...

  • Page 6: 1.4

    6 technical data for the accessory item 6 720 612 218 gb (05.09) 1.4 description of function • the integrated temperature sensor indicates the current room tem- perature to the td 200. The cur- rent room temperature is shown on the display. • if automatic mode is active on the td 200, it is possible...

  • Page 7: Installation

    7 installation 6 720 612 218 gb (05.09) 2 installation 2.1 assembly the control quality of the rt 10 depends on the installation location. The installation location must be suita- ble for controlling the entire heating system. Fig. 1 select installation location fig. 2 remove front casing danger: ri...

  • Page 8: Installation

    8 installation 6 720 612 218 gb (05.09) fig. 3 fasten base plate to the wall b make all electrical connections (see fig. 4). B replace front cover. 6 720 612 218-05.1r 6 mm 3,5 mm 6 mm 3,5 mm.

  • Page 9: Installation

    9 installation 6 720 612 218 gb (05.09) 2.2 electrical connections b bus connection from the rt 10 to additional devices using the bus (e. G. Td 200): use electrical cables correspond- ing to type h05 vv-... (nym-i...) minimum. Permissible cable lengths from the bus-enabled heatronic 3 circuit board...

  • Page 10: Operation

    10 operation 6 720 612 218 gb (05.09) 3 operation fig. 5 operating elements a selection knob : change the required room temperature until the next switching time of the heating program b button : advances the next switching time and the associated operating mode = high = low = frost to the current t...

  • Page 11: Operation

    11 operation 6 720 612 218 gb (05.09) 3.1 change required room temperature, time limited (a) if the rt 10 displays auto : b use the selection button to change the required room tem- perature for the current operating mode / / between 5.0˚c ... 30˚c. The required room temperature is briefly displayed...

  • Page 12: Operation

    12 operation 6 720 612 218 gb (05.09) 3.3 frost protection 3.3.1 room frost protection if the temperature in the room drops below 5˚c, the heating is switched on. To maintain a minimum 5˚c room tem- perature, the heating is switched on and off as appropiate. 3.3.2 frost operating mode the td 200 ena...

  • Page 13: General Information

    13 general information 6 720 612 218 gb (05.09) 4 general information ... Notes on saving energy: • the temperature in the room where the rt 10 is installed acts as a guide parameter for the entire heat- ing network. As a result, the power of the radiators must be set as low as possible, using therm...

  • Page 14: Troubleshooting

    14 troubleshooting 6 720 612 218 gb (05.09) 5 troubleshooting in the event of a fault in the heating appliance, the display will show e.G. A7 e . In the event of a fault in the rt 10, the display will show e.G. 1a4 e . Here the figure 1 stands for a fault in the rt 10 and the letter e for error (= f...

  • Page 15: Troubleshooting

    15 troubleshooting 6 720 612 218 gb (05.09) complaint cause remedy required tem- perature not reached thermostatic valve(s) in the room set to low open the thermostatic valve(s). Flow temperature control- ler on the heating appli- ance set too low set flow temperature controller higher. Air lock in ...

  • Page 16

    Installation, user instructions & customer care guide worcester, bosch group cotswold way, warndon, worcester wr4 9sw. Tel. 01905 754624 fax. 01905 754619 www.Worcester-bosch.Co.Uk worcester bosch group is a trading name of bbt thermotechnology uk ltd. 6 720 612 218 (05/09) osw.