Workhorse ATV 2507 Assembly, Operation And Parts Manual

Summary of ATV 2507

  • Page 1

    — general information — warranty / parts / service 25 gallon deluxe atv sprayer - 7 nozzle atv 2507 — assembly tools required: 1 – 7/16” end wrench 2 – 1/2” end wrenches 1 – thread sealant the purpose of this manual is to assist you in assembling, operating and maintaining your lawn and garden spray...

  • Page 2

    Rate chart for 80/110-02 spray tip — calibration — after spraying — winter storage after use, fill the sprayer part way with water. Start the sprayer and allow clear water to be pumped through the plumbing system and out through the spray wand and boom. Refill the tank about half full with plain wat...

  • Page 3

    Parts list description part number qty item 1/4-20 lock nut 600107 2 1 flange head screw 5/16-18 unc x 1 3/4" 600109 6 2 boom main beam 620100 1 3 boom wing 620101 2 4 left connecting bracket 620102 1 5 right connecting bracket 620103 1 6 spring 620104 2 7 eye bolt 1/2" eye 1/4-20 thread 620105 2 8 ...

  • Page 4

    Parts list description part number qty item 25 gallon tank 600132 1 1 tank lid 600133 1 2 tank lid tether 600134 1 3 tank drain cap 600136 1 4 tank drain cap tether 600137 1 5 tank drain cap gasket 600138 1 6 spray wand clip 600151 2 7 wand clip screw 600152 2 8 lead wire assy. W/ switch (96") 60015...

  • Page 5

    Insert angle brackets in mounting brackets and rotate lever to lock in place. Attach boom hose to valve attach boom clamps to boom in 7 locations install hold down straps in locations shown. (straps not included) complete assembly precision spray equipment ® , a divison of green leaf, inc. 9490 n ba...

  • Page 6

    To spray boom relief hose to top of tank. This lever turns the spray boom on and off. This lever adjusts the system pressure by relieving liquid back to the tank. Adjusting this lever will increase or decrease pressure to both the spray boom and the spray wand. To spray wand pump view looking down o...

  • Page 7: Powerflo

    Powerflo ™ 7800 series 12 volt dc motor-driven diaphragm pumps specifications — motor: type: 12 vdc, permanent magnet, totally enclosed, non-ventilated leads: 18 awg, 12” long duty cycle: see heat rise graph temperature limits: motor is not equipped with thermal protection. For user safety, optimal ...

  • Page 8

    Troubleshooting guide — problem/causes and remedies: pump will not start check: • correct voltage (±10%) and electrical connections • fuse or breaker • pressure switch operation and correct voltage at switch • rectifier or motor for open or grounded circuit • locked drive assembly pump will not prim...