Workhorse LG 25 DSS Assembly / Operation Instructions / Parts

Summary of LG 25 DSS

  • Page 1

    — general information — warranty / parts / service — operation warning: some chemicals will damage the pump valves if allowed to soak untreated for a long period of time. Always flush the pump with water after use. Do not allow chemicals to sit in pump for extended times of idleness. Follow chemical...

  • Page 2: Instruction #1

    4 6 8 3 5 10 9 to s pr ay w an d 1 11 2 7 attach spray boom hose assembly here 1 4 2 3 7 5 6 instruction #1 to order replacement parts: 1-800-654-9808 deluxe spot sprayer instructions: 3.0 --install gauge (item 5) in fitting as illustrated using a good grade thread sealant to prevent leaks. Note: do...

  • Page 3: Powerflo

    Powerflo ™ 7800 series 12 volt dc motor-driven diaphragm pumps specifications — motor: type: 12 vdc, permanent magnet, totally enclosed, non-ventilated leads: 18 awg, 12” long duty cycle: see heat rise graph temperature limits: motor is not equipped with thermal protection. For user safety, optimal ...

  • Page 4

    Troubleshooting guide — problem/causes and remedies: pump will not start check: • correct voltage (±10%) and electrical connections • fuse or breaker • pressure switch operation and correct voltage at switch • rectifier or motor for open or grounded circuit • locked drive assembly pump will not prim...