X-TREME 10kVA User & Installation Manual - Product Introduction

Manual is about: Online UPS

Summary of 10kVA

  • Page 2

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 2 uninterruptible power supply table of contents safety instructions and battery care............................................................4 safety instructions................................................................

  • Page 3

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 3 uninterruptible power supply specifications.............................................................................................30 obtaining service........................................................................

  • Page 4

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 4 uninterruptible power supply safety instructions and battery care safety instructions • for parallel system installation please refer to tx90 6kva & 10kva parallel system installation guide • due to small leakage currents gen...

  • Page 5

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 5 uninterruptible power supply 10 kva tower output no. Output rating ratings of output branch circuit over-current protection no.1 (l21-n21) 6 kva, 120 v 45 no.2 (l22-n22) 6 kva, 120 v 45 no.3 (l23-n22) 10 kva, 208 v 50 no.4 (l...

  • Page 6: Product Introduction

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 6 uninterruptible power supply product introduction general characteristics • true online architecture continuously supplies your critical device with stable, regulated, transient-free, pure-sine-wave ac power. • 20 khz pwm sin...

  • Page 7

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 7 uninterruptible power supply single input system block 1. Ups utility input: to provide the ac source to the ups rectifier circuit and charger. 2. Ups utility input breaker: to protect the ups rectifier circuit from over-curr...

  • Page 8

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 8 uninterruptible power supply symbols on the lcd display panel item symbol description 1 line utility or bypass source 2 battery low 3 battery abnormal 4 ups overloaded 5 ups working in specified mode* 6 a blackout transfer oc...

  • Page 9

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 9 uninterruptible power supply 20 utility input normal led 21 bypass input normal led 22 ups under redundancy mode 23 ups under eco mode 24 ups fault or abnormal warning led 25 epo emergency power off 26 er05 battery weak or de...

  • Page 10

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 10 uninterruptible power supply panel explanations front panel 1 3 4 2 11 12 5 9 7 10 6 8 1 2 3 4 5 6 7 8 9 10 11 12 1. Lcd 2. Green led indicates that the ups is able to run under redundancy mode. 3. Solid green led indicates ...

  • Page 11

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 11 uninterruptible power supply g. External battery connector h. External charger connector i. Utility input breaker cb1 k. Cam switch (maintenance bypass switch) l. Input/output terminal block (shown with cover removed) m. Mou...

  • Page 12: Installation and Operation

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 12 uninterruptible power supply installation and operation carefully inspect the ups for shipping damage before installation. Retain the packing material for future use. Unpacking standard package contents: • quick start guide ...

  • Page 13

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 13 uninterruptible power supply l11 not used: all systems are single input n1, l12, g1: the terminals for utility input with single input connection g1: the terminal for ups input ground n1: line 1 (l1) input l12: line 2 (l2) i...

  • Page 14

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 14 uninterruptible power supply output configuration all of the output options shown below apply to 208v input systems and 240v input systems. Option 1: 120v/240vac - this is the default option for all units: each branch max lo...

  • Page 15

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 15 uninterruptible power supply start up in normal mode • open the terminal block cover on the rear panel. Before starting the installation make sure the wiring is connected properly. • make sure the utility input breaker and t...

  • Page 16

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 16 uninterruptible power supply e1 “ok” in self-test e2 “fail” in self-test f “208 vac” in utility input • if the self-test fails the lcd display will change from figure d to figure e2. Then an error code or error status will a...

  • Page 17

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 17 uninterruptible power supply h utility input is “0” and utility abnormal. I check measured values and figures detected by the ups • if you would like to check the measured values and figures detected by the ups, use the scro...

  • Page 18

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 18 uninterruptible power supply k frequency of bypass input l ups output voltage m ups output frequency n ups output load level (%) o battery voltage.

  • Page 19

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 19 uninterruptible power supply p ups inner temperature viewing the ups default settings • after the ups completely starts up, press the (function) key to change the lcd display to figure q1. Q1 buzzer “on”. Use the key to togg...

  • Page 20

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 20 uninterruptible power supply s bypass voltage is adjusted to narrow range. Selectable to lo or hi. T frequency window is +/-3 hz. Selectable to ± 1hz. U inverter output voltage set to 208v. Selectable to 200, 208, 220, 230, ...

  • Page 21

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 21 uninterruptible power supply x ups position in parallel mode y the parallel function is disabled. • press the scroll up key to execute special functions. The functions include buzzer on (as in figure q1), buzzer off (as in f...

  • Page 22

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 22 uninterruptible power supply z press the enter key to save changes. Aa the ups is locked. • turn off the utility input breaker • your setting changes are now complete. • restart the ups troubleshooting when the ups is off du...

  • Page 23

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 23 uninterruptible power supply “bypass” mode. In the upper right-hand corner of the lcd a sign will appear. 4. Turn off the ups utility breaker. You may proceed with ups maintenance now. 5. When you are done with ups maintenan...

  • Page 24: Troubleshooting Guide

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 24 uninterruptible power supply troubleshooting guide troubleshooting if the ups malfunctions during first power up, check the following: a. Is the input and output wiring correct? B. Is the input voltage of the utility within ...

  • Page 25: Communication Software

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 25 uninterruptible power supply communication software hardware setup 1. Connect the male connector of the rs-232 cable to the ups communication port. 2. Connect the female connector of the rs-232 cable to a dedicated rs-232 po...

  • Page 26: Optional Interface Cards

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 26 uninterruptible power supply optional interface cards relay (dry contact) card pin assignments of 10-pin terminal: 1 2 3 4 5 6 7 8 9 10 pin 1: ups on bypass mode pin 2: utility abnormal pin 3: utility normal pin 4: inverter ...

  • Page 27

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 27 uninterruptible power supply interface card installation 1. 3. 2..

  • Page 28: Replacing Batteries

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 28 uninterruptible power supply replacing batteries to be performed by qualified personnel only 1. Unscrew the bottom of the front panel as indicated in step 1 below. 2. Remove the front panel as indicated in step 2. Tx90-6k sh...

  • Page 29

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 29 uninterruptible power supply 6. Rotate the battery pack handle 90 degrees as shown in step 6. 7. Remove the battery packs from the ups as shown in step 7..

  • Page 30: Specifications

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 30 uninterruptible power supply specifications model number tx90-6k tx90-10k input capacity 6kva (5.4kw) 10kva (9kw) voltage range 160–280vac* frequency 45–65hz auto-sensing power factor up to 0.99 at linear load harmonic disto...

  • Page 31: Obtaining Service

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 31 uninterruptible power supply obtaining service if the ups requires service: 1. Use the troubleshooting section in this manual to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. 3. Call your dealer ...

  • Page 32

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 32 uninterruptible power supply xtreme power conversion limited warranty xtreme power conversion (xpc) corporation warrants xtreme power conversion equipment, when properly ap- plied and operated within specified conditions, ag...

  • Page 33

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 33 uninterruptible power supply xtreme power conversion load protection policy this policy is not a warranty. Refer to the xpc corporation, inc. Limited warranty for information concerning the warranty for your xpc product. The...

  • Page 34

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 34 uninterruptible power supply product. Only those devices registered in that manner will be covered. 2. All connected equipment must be ul or csa approved. 3. The product must be plugged into a properly wired and grounded out...

  • Page 35

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 35 uninterruptible power supply must be completed and filed with xpc within 30 days. • mark the load protection policy rma number on the product the purchaser is returning. • pack the product in its original packaging or simila...

  • Page 36

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 36 uninterruptible power supply appendix a: t90-ebp920, ebp940, ebp960 user guide important safety instructions (save these instructions) this manual contains important instructions that should be followed during installation a...

  • Page 37

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 37 uninterruptible power supply introduction to the rear panel rear panel descriptions t90-ebp920, ebp940, ebp960 product label dc breaker ups connector battery/charger connector.

  • Page 38

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 38 uninterruptible power supply installation and operation note: the packing condition and the external outlook of the unit should be inspected carefully before installation. Retain the packing material for future use. Unpackin...

  • Page 39

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 39 uninterruptible power supply installation of casters cover installation instructions.

  • Page 40

    Xtreme power conversion corporation tx90 6kva & 10kva user’s manual page 40 uninterruptible power supply specifications t90-ebp920 t90-ebp940 t90-ebp960 dimensions (w x d x h) unit 11.4 x 25.4 x 29.5 in weight unit 254 lbs 364 lbs 474 lbs.