  • Page 1

    1 modules & connecting blocks 791-44 installation instructions 791-44 amplified connecting block the model 791-44 is an amplified connecting block that permits up to 10 single or 10 dual emitters (or any combination thereof) to be driven directly at high or low power levels. Up to 100 emitter ports ...

  • Page 2

    2 791-44 2. Be sure to connect the +12v, output and gnd of each ir receiver and keypad to the respective +12vdc, ir in and gnd of the connecting block as shown. 3. Power supply requirements. You may combine many xantech keypads, ir receivers, controllers and emitters in a system. Having sufficient p...

  • Page 3

    3 modules & connecting blocks 791-44 e) now add up all the currents from steps 1 through 4. 10 ma + 85 ma + 10 ma + 18 ma = 123 ma total. Therefore, in this case, one 781rg power supply can be used. Note: to avoid current "hogging", never connect regulated supplies, such as the 781rg or the 782-00, ...

  • Page 4

    4 791-44 2. The high power mode may be used in installations where you mount the emitters on an adjacent cabinet wall or door a short distance from the unit's sensor. Another instance is when you place an emitter inside the device, but cannot place it close to the ir sensor. In such cases, you may n...

  • Page 5

    5 modules & connecting blocks 791-44 room 2 out v ir rcvr pwr gs 291-10 hidden link™ ir receiver gnd ir out +12v 7 foot quick connect cable cb12 connecting block x +12v status gnd ir out 780-80 ir receiver ® 791-44 amplified connecting block satellite receiver av receiver vcr main room, equipment ca...