Xantech 796-20 Installation Instructions

Summary of 796-20

  • Page 1

    1 modules & connecting blocks installation instructions fig. 1 model 796-20 six zone connecting block/expander a b a b a b zone 9 zone 8 zone 7 common zone ir inputs zone 7 zone 8 zone 9 +12 in g +12 in g +12 in g zone 6 zone 5 zone 4 zone ir inputs +12 in g +12 in g +12 in g a b a b a b zone 4 zone...

  • Page 2

    2 796-20 note: because the 730-00 smart pad keypads are not ir receivers, this restriction does not apply to them. They may be added virtually without limit, provided power supply requirements are taken into consideration. See item 3 below. 2. Be sure to connect the +12v , output and gnd of each ir ...

  • Page 3

    3 modules & connecting blocks 796-20 4. The resistors in series with each zone and the common out port provides current sharing to each emitter and also allows the use of dual emitters in combination with single emitters. You may, therefore, connect any combination of emitter models 282, 283, 284 & ...

  • Page 4

    4 emitter expansion 1. Zone output ports. Since the 796-20 zone output ports (a and b) are driven in parallel and have a 470-ohm resistor in series with each, you may expand up to four emitters simply by using two dual emitters, such as the 284-00 or the 286-00. To expand beyond 4 emitters, connect ...

  • Page 5

    5 modules & connecting blocks fig. 5 an 18-zone system using three 796-20's connecting multiple 796-20's for zone expansion fig. 5 shows how three 796's may be connected for an 18-zone system. The three wire common connections from each 796 are paralleled at the input of a 791-44 amplified connectin...