Xantrex 807-1055 Owner's Manual - About This Guide

Other manuals for 807-1055: Owner's Manual
Manual is about: Freedom HFS Inverter/Chargers

Summary of 807-1055

  • Page 1

    Tm tm freedom hfs inverter/chargers owner’s guide product image shown may vary from actual product. See features for comparisons. Model product numbers 807-1055 807-1055-02 807-2055 807-2055-01 807-2055-02.

  • Page 3

    975-0727-01-01 i copyright © 2015 schneider electric. All rights reserved. All trademarks are owned by schneider electric industries sas or its affiliated companies. Exclusion for documentation u nless specifically agreed to in writing , seller ( a ) makes no warranty as to the accuracy , sufficienc...

  • Page 4: About This Guide

    Ii freedom hfs owner’s guide about this guide purpose the purpose of this owner’s guide is to provide explanations and procedures for operating, maintaining, and troubleshooting a freedom hfs sine wave inverter/charger for recreational, fleet vehicle, or marine installations. For complete informatio...

  • Page 5

    975-0727-01-01 iii important safety instructions important: r ead and save this o wner ’ s g uide for future reference . This guide contains important safety instructions for the freedom hfs sine wave inverter/charger that must be followed during operation and troubleshooting. Read and keep this own...

  • Page 6

    Iv freedom hfs owner’s guide safety information 1. Before using the inverter/charger, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual. 2. Use of accessories not recommended or sold by the manufacturer may result in a risk of fire,...

  • Page 7

    • apply appropriate personal protective equipment (ppe) and follow safe electrical work practices. See nfpa 70e or csa z462. • this equipment must only be installed and serviced by qualified electrical personnel. • never operate energized with covers removed. • energized from multiple sources. Befor...

  • Page 8

    Physical injury hazard this freedom hfs sine wave inverter/charger is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the applianc...

  • Page 9

    975-0727-01-01 vii 4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least twenty minutes and get medical attention immediately. 5. Use extra caution to reduce the risk of dropping a metal ...

  • Page 10

    Viii freedom hfs owner’s guide precautions when placing the inverter/charger do not install the inverter/charger or any part of its supplied wiring in engine compartments. Burn hazard avoid touching the external surfaces - heatsink may be hot. • never allow battery acid to drip on the inverter/charg...

  • Page 11

    975-0727-01-01 ix fcc information to the user this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. ...

  • Page 13: Contents

    Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Iii introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 15: Introduction

    975-0727-01-01 1 introduction the freedom hfs sine wave inverter/charger (freedom hfs) is designed with integrated inverting–charging functions and power management features suitable for marine, recreational, and commercial vehicle installations. Please read this chapter to familiarize yourself with...

  • Page 16

    2 freedom hfs owner’s guide introduction key features power for most appliances the freedom hfs inverter/charger provides up to 1000 watts a or up to 2000 watts b of continuous utility grade, sine wave power derived from a battery bank. It is designed to handle loads such as microwave ovens, tvs, dv...

  • Page 17

    975-0727-01-01 3 introduction over temperature alarm and shutdown during inverter mode, the freedom hfs automatically alerts you if it is overheating and approaching the over-temperature shutdown limit. The freedom hfs automatically shuts down when the limit is exceeded. Low power consumption when t...

  • Page 18: Features

    4 freedom hfs owner’s guide features table 1 lists the default settings for the freedom hfs system. You may record your settings in the right-hand column after you have configured the freedom hfs. Table 1 freedom hfs default values item default setting your setting alarm* on ( d/ ) low voltage shutd...

  • Page 19

    975-0727-01-01 5 features front panel (truck model) r eset t est test re set freedom hfs 2 1 3a 3b 4 4 5 feature description 1 display panel displays inverter status and battery status information on the screen. The panel can be detached to extend and mount the panel on a wall or other location. 2 g...

  • Page 20

    6 freedom hfs owner’s guide features rear panel (ems models) 4 1 2 3 feature description 1 negative dc cabling terminal that is pre-connected to an 18-inch (0.45m) battery cable a a. Freedom hfs 1055 120vac ems has a cable size of 2 awg with sb175 anderson con- nector and freedom hfs 2055 120vac ems...

  • Page 21

    975-0727-01-01 7 features display panel (all models) 4 1 2 3 feature description 1 inverter power button is the main unit switch that turns the freedom hfs’s inverter mode on or off. See page 16 for additional information. 2 three-digit led display screen shows status information and fault codes. Se...

  • Page 22

    8 freedom hfs owner’s guide features side panel (all models) 1 2 3 feature description 1 20 a supplementary protector provides overload protection for the gfci receptacles. In a hard wired installation, the supplementary protector does not protect output wiring. However, for the ems models, the hard...

  • Page 23

    975-0727-01-01 9 freedom inverter/charger configuration setting battery types on the main unit you can attach different types of lead-acid batteries to the freedom hfs. Before installing batteries make sure that you configure the unit to optimize the charging process. The settings can be changed usi...

  • Page 24

    10 freedom hfs owner’s guide freedom inverter/charger configuration inverter mode setting ,1or ,1or ,q none alarm setting d/or $/ none low voltage setting vg/or vg0 or vg+ none battery type setting )/gorj(/or $*or), none fixed voltage setting a .To. None a. Appears only when the battery type setting...

  • Page 25

    975-0727-01-01 11 freedom inverter/charger configuration adjusting feature settings the power and select buttons can be used to: • change the charging current setting • change the inverter mode setting • disable or enable the audible alarm • change the shutdown setting • change the battery type sett...

  • Page 26

    12 freedom hfs owner’s guide freedom inverter/charger configuration to change the charger’s charging current setting: by default the charging current is set to $. 1. Press and hold the inverter power button for five seconds. The led screen will flash “ &xu” intermittently. 2. Press the select button...

  • Page 27

    Note: inverter mode on (“ ,q”) will put the inverter on standby with the power save feature. Inverter mode on (“ ,q”) will put the inverter on standby but without the power save feature. Both inverter modes mean that when shore power is present, ac shore power will pass through as ac output. And whe...

  • Page 28

    14 freedom hfs owner’s guide freedom inverter/charger configuration to adjust the low battery shutdown setting: by default the low battery shutdown voltage setting is set to low (“ vg/”). 1. Press and hold the inverter power button for five seconds. 2. Press the inverter power button until the led s...

  • Page 29

    975-0727-01-01 15 freedom inverter/charger configuration to adjust the fixed voltage setting: note: this setting is possible only when the battery type setting is set to ),. See “to adjust the battery type setting:” on page 14. By default the fixed voltage setting is set to 13.5 volts (“ .”). 1. Pre...

  • Page 30

    16 freedom hfs owner’s guide freedom inverter/charger operation display panel operation the freedom hfs features a display panel with three-digit led display to show inverter, ac source, and battery status information. 4 1 2 3 see note in feature # 4. Feature description 1 inverter power button • pr...

  • Page 31

    975-0727-01-01 17 freedom inverter/charger operation 4 select button • during inverter operation, press the button to choose what appears in the three-digit led display: battery voltage, battery current, or output power. See “to change the inverter mode setting:” on page 12. Note: a corresponding le...

  • Page 32

    18 freedom hfs owner’s guide operating in shore power mode the freedom hfs operates in shore power mode when an ac source (a generator or utility power) is present at the ac input terminals. When the ac source is within operating range, the freedom hfs unit bypasses inverter mode and powers the appl...

  • Page 33: Operating In Inverter Mode

    975-0727-01-01 19 operating in inverter mode the freedom hfs is in inverter operation (operating in inverter mode) when all the following conditions exist: • inverter power button is on • inverter mode setting is on • shore power is not presently available • battery has sufficient power inverter ope...

  • Page 34

    20 freedom hfs owner’s guide operating in inverter mode status led during inverter operation the following summarizes the behavior of the status led during inverter operation. Table 2 status led during inverter operation status led display screen condition solid yellow . (where 12.8 is an example of...

  • Page 35

    975-0727-01-01 21 operating in inverter mode checking battery status during inverter operation, you can check the battery status by pressing the select button until the battery voltage led (or battery current led) illuminates. The battery voltage (or battery current) appears in the three-digit led d...

  • Page 36

    22 freedom hfs owner’s guide operating during transition between shore power and inverter mode the freedom hfs’s advanced power management is capable of transitioning power from an ac source to dc source within a fraction of a second and vice-versa. The freedom hfs automatically detects when shore p...

  • Page 37

    975-0727-01-01 23 operating during transition between shore power and inverter mode operating limits power output the freedom hfs can deliver up to 1000 watts or 2000 watts of continuous utility grade sine wave ac power. The wattage rating applies to resistive loads such as incandescent lights. Inpu...

  • Page 38

    24 freedom hfs owner’s guide operating during transition between shore power and inverter mode overload conditions there are two kinds of overload conditions: • an overload warning • an overload shutdown overload warning when the freedom hfs’s ac load is approximately 100 w below the overload shutdo...

  • Page 39: Battery Charging

    975-0727-01-01 25 battery charging battery charging is possible only when shore power is present and the freedom hfs unit is connected to a battery (or battery bank). The frequency of battery charging is determined by how much energy in the battery is used up during inverting. Whenever the freedom h...

  • Page 40

    26 freedom hfs owner’s guide battery charging table 3 illustrates the battery charging status as shown on the status led and display screen. Table 3 battery charging status led status led display screen condition solid green )8/ battery is full. Flashing green %8/— &+j—. (where 12.8 is an example of...

  • Page 41

    975-0727-01-01 27 battery charging routine maintenance freedom hfs unit minimal maintenance is required to keep your freedom hfs operating properly. Periodically you should: • clean the exterior of the unit with a damp cloth to prevent the accumulation of dust and dirt. • ensure that the dc cables a...

  • Page 42

    28 freedom hfs owner’s guide invert power derating vs. Ambient temperature if the unit is in inverter mode and in elevated ambient temperature above 25 °c, you will have to reduce power draw according to the following chart to avoid over-temperature shutdown. 25 30 35 40 45 50 750 800 850 900 1000 @...

  • Page 43: Troubleshooting

    975-0727-01-01 29 troubleshooting do not disassemble the freedom hfs. It does not contain any user- serviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn. To obtain service go to “contact information” on page i. This section will help you narrow down ...

  • Page 44: Warning Messages

    30 freedom hfs owner’s guide warning messages warning messages in the form of audible alarms and error codes that appear on the display panel screen to alert you to an impending system change. Warnings do not affect operation. With the exception of the error codes displayed on the screen, only the a...

  • Page 45

    975-0727-01-01 31 warning messages ( low battery voltage detected depending on setting, see “operating limits” on page 23. Inverting • check battery status and recharge if necessary. • check for proper dc cable sizing. • check for loose connections and tighten if necessary. ( ac output overload warn...

  • Page 46

    32 freedom hfs owner’s guide warning messages for error code (: • the display screen and the alarm will turn off after 30 seconds • after a five-minute shutdown delay, the unit will immediately stop inverting for error codes ( to (: • the unit will stop inverting for error codes (: • the unit will s...

  • Page 47: Troubleshooting Reference

    975-0727-01-01 33 troubleshooting reference do not disassemble the freedom hfs. It does not contain any user-serviceable parts. Attempting to service the unit yourself could result in an electrical shock or burn. Electrical shock and energy hazard failure to follow these instructions can result in d...

  • Page 48

    34 freedom hfs owner’s guide troubleshooting reference no output voltage. The status led is red. Ac shore power is not available or out of operating range and the inverter has shut down with the display screen showing one of the following error codes: • low input voltage (fault code () • check the d...

  • Page 49

    975-0727-01-01 35 troubleshooting reference no output voltage. The status led is green or yellow. Gfci has tripped or supplementary breaker has tripped. Circuit breaker on the ac load panel or ac output disconnect has tripped. Battery voltage is too low (depending on setting, see “operating limits” ...

  • Page 50

    36 freedom hfs owner’s guide troubleshooting reference no output voltage. The status led is not lighting up. The jumper wire on the power module panel connecting the “ignition control” and “disabled” terminals is removed and there is no ignition signal present. Ensure the jumper wire is installed if...

  • Page 51: Inverter Applications

    975-0727-01-01 37 inverter applications the freedom hfs performs differently depending on the ac loads connected to it. If you are having problems with any of your loads, read this section. Resistive loads these are the loads that the inverter finds the simplest and most efficient to drive. Voltage ...

  • Page 53: Specifications

    39 freedom hfs owner’s guide specifications note: specifications are subject to change without prior notice. Physical specifications freedom hfs 1055 models freedom hfs 2055 models l × w × h 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm) 19.2” (487mm) × 9.4” (240mm)× 4.7” (120mm) net weight 11 lbs (5 kg...

  • Page 54

    40 freedom hfs owner’s guide specifications note: these are inverter specifications. Dc input freedom hfs 1055 models freedom hfs 2055 models operating voltage range for all models 10.5–16.5 vdc (low limit) 11.8–16.5 vdc (mid limit) 12.1–16.5 vdc (high limit) 10.5–16.5 vdc (low limit) 11.8–16.5 vdc ...

  • Page 55

    975-0727-01-01 41 specifications note: these are charger specifications. Ac input all models operating voltage range 90–140 vac safe non-operating voltage range up to 240 vac full load maximum current 16 arms nominal frequency 60 hz dc output all models nominal voltage 12.0 vdc min battery voltage f...