Xantrex BC Series Installation Instructions - Installing The

Summary of BC Series

  • Page 1

    The easy shunt™ (part #: 808-8020-00) is an option that you can purchase for use with your xc series or bc series battery charger. It is installed on bank 1 and acts as a temperature sensor during normal operation, providing improved battery voltage charge control. It also provides an amp-hour usage...

  • Page 2: Installing The

    Xantrex xc series and bc series battery charger 2 975-0191-01-01 installing the easy shunt™ sensor to install the easy shunt™ : 1. Switch off all devices operating from the battery. Disconnect all the wires from the negative terminal of the battery (which is connected to bank 1 on the xc or bc serie...

  • Page 3: Using The

    Easy shunt™ installation instructions 975-0191-01-01 3 4. Attach all wires removed in step 1 back onto this new "load" shunt terminal. 5. Tighten the nuts to 8 – 9 nm (6 – 7 ft-lbs) to secure these electrical connections. 6. Route the sensor cable to the charger and plug it into the bank 1 connector...

  • Page 4

    Xantrex xc series and bc series battery charger 4 975-0191-01-01 3. The remote display will scroll the following information, in order, on bank 2 and then bank 3: • highest priority charger fault or warning (if present) • highest priority battery fault or warning (if present) • battery voltage amp-h...