XDEEP BLACK EANX User Manual

Summary of BLACK EANX

  • Page 1

    User’s manual oled dive computer firmware version 2.9.3.

  • Page 2

    3 2 the xdeep black eanx is an advanced dive computer, in which we have incor- porated cutting edge technology and high quality components from the world leading manufacturers. While creating the black eanx, we did our best to satisfy your expectations and make your dives safer and more pleasant. If...

  • Page 3

    5 4 in this manual some information was marked in a special way by presenting it in a frame with an international symbol. Pay special attention to it. Attention this symbol is used to indicate significant practical information related to the use of the black eanx. This symbol was used to indicate in...

  • Page 4

    7 6 before you move to further instructions or/and start using black eanx dive computer, read carefully all warnings and information described below and always follow them. Read before use 2/4 • before you start using the black eanx diving computer, and after reading this manual, practice using the ...

  • Page 5

    9 8 • exceeding the max. Ascent rate may lead to decompression sickness which in turn can lead to serious injury or death. Never exceed the optimal and maximum ascent rates recommended by the diving federation with whom you completed your diving courses, regardless of the readings of the speed indic...

  • Page 6

    11 10 attention! The decompression algorithm is based on simulated tissues and calculates the saturation of tissues with inert gases in a continuous manner – both during the dive and on the surface. Pay special attention to the following information that will be displayed every time the device is re...

  • Page 7

    13 12 the black eanx can be fixed on the hand with the supplied strap. In order to fix it, you need to thread the strap through the holes in the case, as shown in figure below: basic elements ambient light sensor pressure sensor usb port oled 1.8” screen mounting points of strap and bungee cords. St...

  • Page 8

    15 14 the black eanx has four holes for bungee cord mounting: in order to install the bungee cord: 1. Tie a knot at the end of the cord. Next, thread the bungee cord through hole a so that the knot is placed from the display side. 2. Thread the end of the bungee cord through holes b, c and d. The le...

  • Page 9

    17 16 if the black eanx was used during a dive, then after completing the dive the main screen will display the following information: • surface interval – time in hours since surfacing from previous dive. • nofly – minimum time in hours during which you mustn’t travel by plane or in- crease your al...

  • Page 10

    19 18 the black eanx has two buttons. Each of these buttons detects both a ‘quick press’ (under 0.5s) and ‘hold’ (over 0.5s). Button functions for the main screen, additional information screen and com- pass screen: in the menu, functions assigned to ‘hold’ are described on the screen: buttons hold ...

  • Page 11

    21 20 the black eanx enables operation in three operation modes: • gauge (bt) – measurement mode. The device does not calculate no-decom- pression time (ndl) and decompression stops. • air – air computer mode. The device shows ndl time and decompression stops using only air (21% of oxygen, 79% of ni...

  • Page 12

    23 22 the black eanx is equipped with a water sensor that is activated automati- cally once in contact with water; therefore, it does not require to be turned on manually before entering the water. It enters diving mode at a depth of 1.5m. Water sensor was calibrated to detect both salt and fresh wa...

  • Page 13

    25 24 the main screen of the device contains all basic information on the current situation of the dive: in the gauge (bt) mode, device shows average dive depth instead of ceiling. During the dive, in the main menu there are additional functions: allows switching of the currently used breathing gas ...

  • Page 14

    27 26 while diving with the black eanx in gauge mode (bt), you can select one of three layouts of the main screen: full, simplified and minimal. The layouts differ from one another in terms of the amount of displayed information. Attention! If you begin the dive breathing a gas other than the primar...

  • Page 15

    29 28 the „deco info” screen contains additional information related to diving, es- sential in particular for technical divers during decompression dives or divers using enriched air: in the upper part of the screen there is the name of the active gas. Below there is the following information: • ppo...

  • Page 16

    31 30 after commencing the dive, the black eanx displays the remaining no-decom- pression time (ndl) in minutes. When the remaining no-decompression time amounts to less than 30s, the ndl value begins to blink to inform the user that the no-decompression limit will be exceeded very soon. Diving with...

  • Page 17

    33 32 when during a dive, the no-decompression time limit is exceeded, the black eanx will automatically switch into decompression mode and instead of ndl it will display information on the nearest decompression stop: the stops are displayed at depths being the multiple of 3m (or 10 feet in case of ...

  • Page 18

    35 34 for optimal decompression, it is necessary for the diver to remain within the stop zone during the entire time limit. The stop zone stretches between the current decompression ceiling and the displayed stop depth + 0.5m. Remaining below the stop depth will result in extending the stop time lim...

  • Page 19

    37 36 after performing all decompression stops the device will display information “surface” which means that the diver can slowly ascend to the surface. For your own safety and good feeling after the dive, after the last stop it is recom- mended to ascent at the rate of 1m/min. After completing the...

  • Page 20

    39 38 at a depth of 0.5m, before reaching the gas switching depth the device will signal the need to switch gases in the upper line displaying the gas switching icon with the name of the gas which shall be switched to: the information about gas switching will be displayed for as long as the device i...

  • Page 21

    41 40 after approving the gas switch, the black eanx will automatically return to the main screen and in the place where the decompression stop is normally displayed, the name of the gas that was activated will be displayed for three (3) seconds. It’s your obligation to verify whether this is the co...

  • Page 22

    43 42 the black eanx has the following alarms: the alarm can be turned off using ‘turn off alarm’ function available in the main menu. The fact that the alarm occurred is saved and indicated in the logbook. Alarm display 2/2 alarm is activated once a particular dive time is exceeded. Alarm is activa...

  • Page 23

    45 44 the black eanx, like any other electronic device, may fail during a dive. We strongly advise against performing no-decompression dives with the use of only one device for measuring time and depth. Note that all recognized diving federations prohibit performing decompression dives with the use ...

  • Page 24

    47 46 the compass functions are available in the compass context menu. In order to enter it, hold the right button on the compass screen. The compass context menu contains the following functions: the compass screen presents all information required for navigation and infor- mation relating to the c...

  • Page 25

    49 48 the digital black eanx compass allows you to set the course (bearing lock) and then navigating it. In order to set the course, set the compass bearing, so that it is placed in the axis between you and the destination you wish to reach. Then select “lock bear- ing” in the compass context menu. ...

  • Page 26

    51 50 the black eanx is equipped with a diving compass that is the first in the world to provide navigation by a set course list. This feature allows you to navigate easily in the water and visit all attractions successively. The course list contains the course and time necessary to cover a particul...

  • Page 27

    53 52 for a period of time after a dive, it is not allowed to travel by plane or increase altitude (including travelling in the mountains). The minimum time period within which flying is not allowed is displayed in hours on the main screen of the sur- face mode and marked with the notice “no fly”. T...

  • Page 28

    55 54 if the diver ascended when the device displayed the need to perform a decom- pression stop, the computer will be blocked for 24h and diving with it will not be possible. When blocked, the computer does still allow you to enter the logbook, settings and other functions. Information on blocking ...

  • Page 29

    57 56 the black eanx enables exporting of data to a file in uddf format compatible with most of the good logbook programs for stationary computers. In order to generate a uddf file for a particular dive, enter the data in the logbook and then on the first page (basic information) hold the right butt...

  • Page 30

    59 58 settings – basic parameters change of language in which the information is displayed. Selection of unit display method (metric/imperial). The set of functions allowing the date and hour and time display mode (12h/24h) setting. Settings >> language settings >> units settings >> date and hour in...

  • Page 31

    61 60 settings >> computer >> algorithm this function makes it possible to select the decompression algorithm. At pre- sent, there is only one algorithm available: buhlmann zhl-16c + gf. Settings >> computer >> last stop dep. This function makes it possible to select the depth of the last decompress...

  • Page 32

    63 62 black eanx during calculations with the use of buhlmann zhl-16c model + gf uses the idea of variable conservatism based on the so-called „gradient fac- tors” developed by eric c. Baker. Black eanx, depending on the operation mode, enables changing gf parameters in two ways: • in „air” and „ean...

  • Page 33

    65 64 set the conservatism at level 3 when there is at least one factor which may increase the risk of dcs or you dive in water of temperature below 10°c or you dive 300m above sea level or you dive the third day in a row or longer or you are older than 40 years. Set the conservatism at level 2 (def...

  • Page 34

    67 66 in “adv. Eanx” mode the conservatism is set separately for non-decompression and decompression dives using the following functions: settings >> computer >> gf for ndl this function makes it possible to select the value of gradient factor which is taken into account when calculating no-decompre...

  • Page 35

    69 68 settings >> computer >> repetitive adj. This function switches on and off the conservatism adjustment for repetitive dives. When the function is on, black eanx automatically increases the con- servatism in multi-day dives and in situations when the surface interval is relatively short, by shor...

  • Page 36

    71 70 the first gas on the list is always the primary gas – there is no possibility to deactivate it and after switching into diving mode the device automatically recognizes it as an active gas. For each gas in the gas list, it is possible to set the following parameters of the breathing gas mixture...

  • Page 37

    73 72 settings >> alarms >> dive time this function sets the dive time alarm. Settings >> alarms >> max. Depth this function sets the maximum dive depth alarm. The alarm will be activated each time the current depth exceeds the set value. Settings >> alarms >> average depth this function sets the av...

  • Page 38

    75 74 settings >> alarms >> alarm clock this function sets the alarm which is activated at a particular hour in dive mode. Settings >> alarms >> ppo2 this function makes it possible to set the level of oxygen partial pressure (ppo2) above which the alarm will be displayed. It can be set at values of...

  • Page 39

    77 76 settings >> display >> brightness screen brightness can be set within a range of 25% - 100%. In „auto” mode, adjustment is made via a light sensor in the device case which ensures best readability in varying light conditions. Settings >> display >> colour scheme select from many pre-defined sc...

  • Page 40

    79 78 settings >> usability >> flip this function allows turning on and setting sensitivity of automatic screen flip in situation when the user shows bt to his/her partner. With the set level, the angle at which screen flip occurs is changed. Settings >> usability >> menu timeout this is the interva...

  • Page 41

    81 80 note: locking the keys makes it impossible to use the device functions until it is unlocked manually (including the gas change function). Once this function is activated, you have to practice unlocking the keys in shallow water. Settings – usability parameters 3/3 settings >> usability >> show...

  • Page 42

    83 82 settings >> logbook >> depth interval this is frequency of information log on the current depth in seconds. Settings >> logbook >> temp. Interval this is frequency of information log on the current temperature in seconds. Settings >> logbook >> min. Time this is the time interval in seconds af...

  • Page 43

    85 84 settings >> compass >> calibration this function calibrates the compass and whilst the digital compass was calibrated when manufactured,, we recommend you check the accuracy of its readings. If compass readings are defective, we recommend you calibrate it manually. The compass calibration is a...

  • Page 44

    87 86 settings >> system >> wipeout device this function restores factory settings and removes all data from the logbook. Settings >> system >> unblock this function is available only if device is in “block mode” and switches the device to normal operation mode after blocking. You must refer the “af...

  • Page 45

    89 88 black eanx is equipped with a special four-contact usb port situated on the right side of the device. In order to connect the device to pc with usb port, use the charger plug and usb cable supplied with the device. After correct connection of usb port, enable the usb black eanx port by functio...

  • Page 46

    91 90 the black eanx does not contain any elements that can be serviced by the user. In case of any irregularities in the devices operation, the device must be withdrawn from use and the user should contact the producer. The maximum time period recommended before checking the accuracy of the reading...

  • Page 47

    93 92 1. Subject of the agreement the subject of this agreement is to determine the rules according to which the licensor grants the license to the licensee to use black eanx decompression software and establish exclusions and limitations of liability of xdeep. Under the terms of this agreement, xde...

  • Page 48

    95 94 5. No other representations, warranties or guarantees to the maximum extent permitted by law, the warranties provided under guarantee certificate enclosed to this agreement are licensee sole and exclusive rights, and xdeep’s sole and exclusive liabilities and obligations to licensee, in connec...

  • Page 49

    97 96 8. Limitation of liability if notwithstanding the provisions of sections 5, 6 and 7 of this agree- ment xdeep has any liability or obligation to licensee, xdeep’s total cumulative liability, including damages and compensations, to licensee or to any other person arising from, connected with, o...

  • Page 50

    99 98 these terms of guarantee concern the black eanx diving computer hereinaf- ter referred to as „the product”. The guarantee covers physical defects which occur only due to reasons within the product and resulting only from latent material or performance defects, as long as they are detected with...

  • Page 51

    101 100 technical specification 1/4 hardware features processor flash memory screen compass communication port dimensions buttons built-in sensors energy micro efm32 giant gecko 8mb oled 1.8” full colour digital, tri-axial usb 2.0 (12mbit/s) 51 x 66 x 32 mm balanced buttons with an electronic pressu...

  • Page 52

    103 102 software operation modes gauge – depth and time measurement air – single gas air computer eanx, adv. Eanx – multigas nitrox computer decompression algorithm maximum percentage o2 ascent speed used for deco calculation number of gas mixes zhl16-c + gradient factor 100% 10m/min 3 enriched air ...

  • Page 53

    © 2015 genz. All rights reserved..