Xinje OP320 User manual

Manual is about: OP series Operate panel

Summary of OP320

  • Page 1

    Op operate panel user manual xinje electric co., ltd. Data no. Hoc01 20110705 8.0

  • Page 2: Basic Instructions

    Basic instructions  thanks for buying op series operate panel.  this manual will introduce the hardware features and wiring of op.  please read the manual carefully before wiring.  for op software, please refer to op software manual.  please pass the manual to the final user. User notes  only ...

  • Page 3: Catalog

    1 catalog 1 hardware ............................................................................................................................... 3 1-1.i ntroduction ......................................................................................................................................

  • Page 4

    2 3-5.k oyo s series plc ......................................................................................................................................... 23 3-5-1.connection unit .......................................................................................................... 23 3-...

  • Page 5: Hardware

    3 1 hardware 1-1.introduction op series operate panel can control the plc through buttons, texts, lamps. Characteristics:  edit the program in op20 software, download program via pc serial port  can communicate with various plcs. Such as mitsubishi fx series, omron c series, siemens s7 series, koy...

  • Page 6

    4 1-3.function specifications op series: type button lcd backlight port dimension (mm) mounting dimension (mm) op320 7 3.7” stn lcd rs232/rs422 162.0×102.0×38.0 156.5×94.0 op320-s rs232/rs485 op320-a 20 rs232/rs422 172.0×94.0×30.0 163.0×85.0 op320-a-n rs232 op320-a-s rs232/rs485 op325-a rs232/rs422 ...

  • Page 7

    5 1-3-3.op325-a/op325-a-s display type blue lcd use life above 20000 hours, temperature 25℃, 24-hour running display area 192*64 brightness adjust by potentiometer text english (24 words×4 rows) font lattice, vector button 20 memory program 64kb falshrom data 1kb sram port download rs232 communicati...

  • Page 8

    6 1-4.part take op320-a for example: set ent alm esc clr +/- 0 3 2 1 6 5 4 9 8 7 note: (1) there is a potentiometer at the reverse side of op cover. It can adjust the lcd brightness. Please rotate it with the screw. The lcd backlight will be off if there are no any operations for 3 mintues. (2) the ...

  • Page 9

    7 1-5.button function the buttons on the op panel can be defined as many functions. They can instead of the buttons on the control machine which has long using life and better touch feeling. Besides, these buttons can be defined to special function such as set on /off bit, screen jump. If no need sp...

  • Page 10

    8 1-6.port and download connection 1-6-1.port op series has a db9 port. It can download program and communicate with other devices. Op320, op320-a, op325-a, op330 op320-a-n op320-s, op320-a-s, op325-a-s, op330-s pin name 1 td+ 2 rxd 3 txd 4 5 gnd 6 td- 7 8 rd- 9 rd+ pin name 2 rxd 3 txd 4 5 gnd 6 7 ...

  • Page 11

    9 1-7.dimension and installation 1-7-1.dimension unit: mm  op320, op320-s 9 3 . 0 153.0 1 0 2 . 0 162.0 set ent 33.7 38.0 156.5 94 .0  op320-a, op320-a-n, op320-a-s set ent alm esc clr +/- 0 3 2 1 6 5 4 9 8 7 172.0 94 . 0 8 4 . 8 162.2 30.0 25.5 85 .0 163.0  op325-a, op325-a-s set ent alm esc clr...

  • Page 12

    10  op330, op330-s 1 21 . 0 162.0 1 11 . 0 56.5 172.0 6 7 8 9 5 4 3 2 1 0 esc alm set ent 1 2 3 4 8 7 6 5 164.0 1 13 . 0 1-7-2.installation op installation diagram: mounting steps: (1) make a mounting hole on the mounting panel (2) put the bottom of op into the hole (3) mount the mounting stand int...

  • Page 13: Q&a

    11 2 q&a op program is edited in op20 software; please refer to op software manual. This chapter will explain some general questions about using op. 2-1.cannot download program 1. The version of hardware and software must be matched. Please see the following table. Hardware version software version ...

  • Page 14

    12 5. Contact us if they still cannot communicate. 2-3.program security op program cannot be uploaded for security reason. 2-4.interactive control please choose “auto change display screen” and set register address in tool/set op series… set the register to n, op will jump to screen no.N when power ...

  • Page 15

    13 2-5.set data in sequence if there are many values need to set in one screen, please click each of them in sequence before downloading. Then you can set these values in sequence. 2-6.others 1. When choosing modbus or free format protocol, op20 will have register 4x, 3x, 1x, 0x. 1x and 3x mean read...

  • Page 16: Plc Connection

    14 3 plc connection this chapter will introduce the connection method of op and plc. The communication steps of plc and op: 1. Choose the plc type communicating with op. Check if the communication parameters of op and plc are the same. The station no. Of each part in the op program should be same to...

  • Page 17

    15 plc software settings: 3-1-3.cable connection 1. Direct connect to xc series plc cpu (rs232 port) xc series plc cpu op rs232 port (port1 or port2) 9-pin d-type female port 8-pin round port (diagram 1: fit for op all series) plc port:.

  • Page 18

    16 2. Direct connect to xc series plc cpu (rs485 port) op xinje xc series plc cpu 9-pin d-type female port rs485 terminal (port2) (diagram 2— fit for op320-s, op320-a-s, op325-s, op330-s) 3. Connect plc via xc-com-bd (rs232) op xc-com-bd 9-pin d-type female port rs232 8-pin port (diagram 3— fit for ...

  • Page 19

    17 3-2.mitsubishi fx series plc 3-2-1.connection unit series cpu connected module port cable choose plc type in op20 fx fx0n fx1n fx2n fx1s fx3u cpu rs422 diagram 1 mitsubishi fx series plc fx3g fx0 fx1 cpu rs422 diagram 1 mitsubishi fx series plc fx2 cpu rs422 diagram 2 mitsubishi fx series plc 3-2...

  • Page 20

    18 plc software settings: 3-2-3.cable connection 1. Fx1n/2n/3u/3g/1s series plc (rs422) mitsubishi plc op fx series cpu rs422 9-pin d-type female port 8-pin round port (diagram 1— fit for op320, op320-a, op325, op330).

  • Page 21

    19 2. Fx2 series plc mitsubishi plc op fx2 series cpu rs422 9-pin d-type female port 25-pin d-type male port (diagram 2— fit for op320, op320-a, op325, op330) 3-3.siemens s7-200 series plc 3-3-1.connection unit op series can communicate with s7-200 series plc (ppi protocol) via programming port or e...

  • Page 22

    20 /19200/187500 parameters station no. 2 must use recommend settings the default parameters of siemens s7-200 series plc: 9600, 8, 1, even parity, station no.2 plc software settings: s7-200 communication notes: 1. Siemens plc register has vb(8-bit), vw(16-bit), vd(32-bit). 2. The register address i...

  • Page 23

    21 3 cj cj1g-cpu44 cj1g-cpu45 cpu rs232 port rs232 diagram 1 cs1 cs1h-cpu63/ 64/65/66/67 cs1g-cpu42/ 43/44/45 cs1g-cpu42h cs1g-cpu43h cs1g-cpu44h cs1g-cpu45h cs1h-cpu63h cs1h-cpu64h cs1h-cpu65h cs1h-cpu66h cs1h-cpu67h cpu rs232 port rs232 diagram 1 c200 c200he cpu rs232 port rs232 diagram 1 cpm cpm2...

  • Page 24

    22 parameters baud rate 9600 4800/38400/9600/115200 /19200/187500 accord with plc port parameters station no. 0 0~255 the default parameters of omron cp/cj/cs series: 9600, 7, 2, even parity, station no.0 (2) omron cpm/cqm series op software settings: parameters recommend settings choices of setting...

  • Page 25

    23 2. Module cp1w-cif11 rs485: op module cp1w-cif11 9-pin d-type female port rs485 terminal (diagram 2— fit for op320-a-s, op320-s, op330-s, op325-s) note: for omron module cp1w-cif11, please turn off sw1; turn on sw2, 3, 6; turn on or off sw4. 3. Module cp1w-cif11 rs422: op module cp1w-cif11 9-pin ...

  • Page 26

    24 sm sm24-t sn su-6 cpu rs232 diagram 1 su-6b rs232 diagram 1 rs422 diagram 3 note: koyo sh-48rs doesn’t have run, stop switch, but only one port (modular plug) 2. Koyo direct logic series dl05, dl250 plc (direct connect to cpu) series cpu connected module port cable choose correct plc in op20 dire...

  • Page 27

    25 /19200/187500 station no. 0 0~255 the default parameters of koyo s series plc: 9600, 8, 1, odd parity, station no.0 plc software settings: 1. Choose k protocol, station no.1 in the software. 2. Koyo k procotol doesn’t have station no. Problem, the communication parameters cannot be changed. It is...

  • Page 28

    26 3. Rs422 connection: su-6b, sg-8(g01-dm), op sr-21/sr-22(e-02dm-r1), dl250 9-pin d-type port rs422 15-pin svga port (diagram 3— fit for op320, op320-a, op325, op330) 3-6.delta dvp series plc 3-6-1.connection unit op can communicate with delta dvp series plc through plc programming port. Series co...

  • Page 29

    27 0 station no. 1 0~255 the default parameters of delta dvp plc: 9600, 7, 1, even parity, station no.1 3-6-3.cable connection 1. Cpu rs232 port: op delta dvp series plc cpu rs232 9-pin d-type port 8-pin port (diagram 1— fit for op all series) 2. Cpu rs485 port: op delta dvp series plc cpu 9-pin d-t...

  • Page 30

    28 3-7-1.connection unit series connected module port cable choose k80 k120 cpu rs232 diagram 1 lg master-k80/120-programming port 3-7-2.communication parameters lg master-k80/120-programming port, op software settings parameters recommend settings choices of settings notes plc type lg master-k80/12...

  • Page 31

    29 3-7-3.cable connection cpu rs232 port: op lg master-k80/120 rs232 9-pin d-type female port 9-pin d-type male port (diagram 1— fit for op all series) 3-8.lg master-k (modbus) series plc (multi-function port) 3-8-1.connection unit connect through modbus rtu protocol series connected module port cab...

  • Page 32

    30 station no. 1 0~255 the default parameters of lg master k-modbus : 9600, 8, 1, even parity, station no.1 plc settings: note: (1)turn on plc switch built-in cnet (2)please choose modbus slave protocol rs232 communication 3-8-3.cable connection 1. Lg modbus rtu rs232: op controller 9-pin d-type fem...

  • Page 33

    31 (fit for : op all series) 2. Lg modbus rtu rs485: op controller 9-pin d-type female port rs485 terminal (fit for : op320-a-s, op320-s, op330-s, op325-s) 3-9.lg master-k (cnet) series plc (multi-function port) 3-9-1.connection unit expansion cnet module: series connected module port cable choose p...

  • Page 34

    32 the default parameters of lg master k-cnet: 19200, 8, 1, no parity, station no.1 plc settings notes: (1)turn on switch built-in cnet of plc. (2)please choose special slave procotol. (cannot choose modbus slave). Rs232 rs485.

  • Page 35

    33 3-9-3.cable connection 1. Cpu(or expansion cnet module) op cnet communication module 9-pin d-type female port 9-pin d-type male port (diagram 1— fit for op all series) note: (1)turn on switch built-in cnet of plc. (2)choose cnet port when making new plc program. 2. Rs485 connection: op cnet commu...

  • Page 36

    34 3-10.matsushita fp series plc op can communicate with matsushita fp series plc through programming port or expansion port. 3-10-1.connection unit series cpu connected module port cable choose plc type in op20 fp fp0 cpu rs232 diagram 1 matsushita fp0/fp1 series fp-m cpu rs232 diagram 1 fp-x cpu r...

  • Page 37

    35 plc settings note: (1) please set the plc register like this in op software: plc op r45 (2)make sure the plc switch is turn to ppog (3)the plc must run when communicating with op. (4)do not choose general communication mode when setting the plc parameters, otherwise, the communication will be err...

  • Page 38

    36 2. Cpu rs232: op plc rs232 9-pin d-type female port 9-pin d-type male port (diagram 2— fit for op all series) 3. Cpu rs422: matsushita mewnet-fp series op fp1 cpu rs422 9-pin d-type female port 8-pin male port (diagram 3— fit for op320, op320-a, op325, op330) 4. Cpu 15-pin port: op plc rs422 9-pi...

  • Page 39

    37 3-11.schneider neza series plc op can communicate with schneider neza plc through programming port. (modbus protocol) 3-11-1.connection unit series cpu connected module port cable choose plc type in op20 micro tsx 37-05 tsx 37-08 tsx 37-10 tsx 37-21/22 cpu rs485 diagram 1 schneider micro/neza/twi...

  • Page 40

    38 plc software settings: note: 1.The register of twido is dynamic managed. Please add a sentence at the end of plc program to avoid communication error. 2. To open the bit address range, you have to make a program as below. For example: drive a coil of %m127, all the addresses before %m127 can do d...

  • Page 41

    39 3-11-3.cable connection 1. Cpu rs485: schneider micro/neza/twido series op tsx-37, tsx-07, twido series cpu 9-pin d-type female port 8-pin male port (diagram 1— fit for op320-a-s, op320-s, op330-s, op325-s) 2. M238 cpu: op schneider micro series cpu 9-pin d-type female port rj-45 port (diagram 2—...

  • Page 42

    40 26mct/36mct rs485 diagram 2 fb -ma 20ma 28ma 40ma fb-dtbr/ dtbr-e module rs232 diagram 3 rs232 diagram 4 rs485 diagram 5 note: for ma series cpu, please transform the com port to rs232 or rs485 through fb-dtbr or fb-dtbr-e module. 3-12-2.communication parameters op software settings parameters re...

  • Page 43

    41 cpu port: 20mc, 28mc, 40mc, 19mct, 26mct, op 36mct series cpu rs232 9-pin d-type female port 15-pin d-type male port (fit for op all series) 2. Cpu rs485: 20mc, 28mc, 40mc, 19mct, 26mct, op 36mct series cpu rs485 9-pin d-type female port 15-pin d-type male port (diagram 2— fit for op320-s, op320-...

  • Page 44

    42 4. Fb-dtbr/dtbr-e rs232: 20ma, 28ma, 40ma series fb-dtbr op /dtbr-e module rs232 9-pin d-type female port 9-pin d-type male port (diagram 4 — fit for op all series) 5. Fb-dtbr/dtbr-e rs485: 20ma, 28ma, 40ma series fb-dtbr op /dtbr-e module rs485 9-pin d-type female port 3-pin terminal (diagram 5 ...

  • Page 45

    43 vb2-16m vb2-32m rs485 diagram 4 vh vh -14mr cpu rs232 diagram 1 3-13-2.communication parameters op software settings parameters recommend settings choices of settings note plc type vigor vb series plc choose correct plc type in op20 port rs232 rs232/rs485/rs422 data bit 7 7/8 accord with plc port...

  • Page 46

    44 3. Cpu rs485 expansion card: (1) rs422 connection vigor vb series op rs485 expansion card 9-pin d-type female port 5-wire terminal (diagram 3— fit for op320, op320-a, op325, op330) (2) rs485 connection vigor vb series op rs485 expansion card rs485 9-pin d-type female port 5-wire terminal (diagram...

  • Page 47

    45 3-14-2.communication parameters op software settings parameters recommend settings choices of settings note plc type emerson ec20 series plc choose correct plc type in op20 port rs232 rs232/rs485 data bit 8 7/8 accord with plc port parameters stop bit 1 1/2 accord with plc port parameters parity ...

  • Page 48

    46 3. Emerson ec20 series plc com1(rs485): emerson-ec20 series cpu op com1 rs485 9-pin d-type female port 5-wire terminal (diagram 3— fit for op320-s, op320-a-s, op325-s, op33-s) note: emerson ec20 series plc com1 has rs232 and rs485. Only one of them can be used at the same time. Do not connect unu...

  • Page 49

    47 2. Idec cpu(micro3c series)rs232: idec plc micro3c cpu op rs232 programming port 9-pin d-type female port 8-pin round male port (fit for op all series) 3-16.keyence kv series plc keyence kv series plc cpu rs232 port: keyence kv-10/16/24/40 series plc op cpu rs232 9-pin d-type female port 6-pin rj...

  • Page 50

    48 3-17.saia-burgess pcd series plc saia-burgess pcd series plc rs232 port: saia-burgess pcd series plc op rs232 9-pin d-type female port 9-pin d-sub port (fit for op all series).

  • Page 51

    Xinje electric co., ltd. 4th floor, building 7th, no.100 dicui rd, wuxi, china tel: 86-0510-85134139 fax: 86-0510-85111290 www.Xinje.Com email: cheerfiona@gmail.Com.