Xmart OPTIMA-33 10K User Manual

Summary of OPTIMA-33 10K

  • Page 1

    English xmart optima-33 10k / 20k ver. 150805 user manual optima-33 10k / 20k / 30k 3 phases in - 3 phases out online-double conversion ups 400/230v & 208/120v technical information on this manual is property of xmart . This manual information cannot be copied or distributed totally or partially wi...

  • Page 2: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 0 table of contents 1. Safety 2. Available models 3.- ups installation: site planing site inspection & installation conditions tower ups installation external circuit breakers & wiring selection 4.- up...

  • Page 3: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 1 1. General safety instructions warning: it is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified tech...

  • Page 4: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 2 • to enlarge batteries life expectancy it is recommendable to fully discharge ups one every 2 to 3 months • during ups storage recharge batteries according to the following table: warning: equipment ...

  • Page 5: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 3 2.- available models optima-33 10k / 20k / 30k - 400/230v ups 3 phases in & 3 phases out for 400/230v systems. Usually this kind of ups include electronic and internal batteries in same ups cabinet. ...

  • Page 6: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 4 rear panel 1.- rs232 7.- fan for power stage / ventilación forzada etapa de potencia 2.- usb 8.- exbatt connector / conector baterías externas 3.- epo (emergency stop / parada emergencia) 9.- ac inpu...

  • Page 7: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 5 3.- ups installation: site planning safety instructions warning: before revising this section you must read and understand very well section 1 of this manual: “general safety instructions”. Warnings,...

  • Page 8: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 6 site inspection and installation conditions regulations and legal directives it is necessary to check that installation site, wiring and power protection in the installation supplied by end user, ful...

  • Page 9: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 7 tower ups installation site considerations * this product has been designed to be used indoors, protected from water, direct sun light, dust and extreme temperature. * install the ups in well ventila...

  • Page 10: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 8 circuit breakers and wiring selection breakers and gauge of the wires used in the installation must be rated to drive current values in amps as indicated in below tables. Note every country has its l...

  • Page 11: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 9 208/120vac input output ext. Batt 10kva (208/120vac) breaker: 63 amps ac (curve d) max. Nominal current (ph-n): - 38a in normal mode (@100v) wiring (min. Recommended size): phase: 8 awg (10 mm2) neut...

  • Page 12: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 10 4.- ups installation: single ups - terminal block ac lines connection procedure • make sure the ups is off before starting the installation. • remember to check all wires to be connected are not pow...

  • Page 13: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 11 external battery cabinets – connection procedure ups tower type warning make sure exbatt model to be connected is compatible with ups model. For optima-33 models, battery pack voltage is 240vdc. Mea...

  • Page 14: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 12 5.- ups installation: parallel ups - terminal block general comments for parallel systems * parallel installation allow up to 3 units in parallel. * all units must have similar control board firmwar...

  • Page 15: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 13 parallel - terminal block wiring.

  • Page 16: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 14 parallel - control cables.

  • Page 17: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 15 6.- start-up: single ups inspection before start up 1. Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures and damage to ups. 2. Make...

  • Page 18: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 16 7.- start-up: parallel ups requirements for parallel system warning: before starting up this parallel ups system is mandatory to comply with all below requirements. 1.- maximum quantity of ups to be...

  • Page 19: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 17 start up for parallel ups system warning: make sure all requirements and previous inspection have been revised and complied before initiating start up procedure. If not please do not try to continue...

  • Page 20: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 18 8.- operation interface ups front panel: push button tower front panel on / enter power on : keep selected during 1 second to power ups on. Enter : it works as “enter” or confirmation function when ...

  • Page 21: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 19 ups front panel: led indicator lights there are 4 led indication lights in front panel, located below lcd. These 4 leds describe ups condition as follow: mode bypass line battery fault ups is in aut...

  • Page 22: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 20 ups front panel: lcd this ups has a sophisticated lcd able to display all important information related to input line, ups status and values, operation mode and error and alarm messages. It is a pow...

  • Page 23: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 21 9.- operation: single ups this is a true on line double conversion ups and it is designed to offer clean, bump-less and highest quality power to your computer related equipments protecting also your...

  • Page 24: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 22 function display according to operation mode in each mode ups will show some different alternating screens as described below: operating mode/status ups power on description when ups is powered on, ...

  • Page 25: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 23 ac mode (normal mode) description when the input voltage is within acceptable range, ups will provide pure and stable ac power to output. The ups will also charge the battery at ac mode. Lcd display...

  • Page 26: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 24 cvcf mode description when the output frequency is set to “cf”, the inverter will output constant frequency (50 hz or 60 hz). At this mode, the ups will have no bypass output but still charge batter...

  • Page 27: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 25 bypass mode description when input voltage is within acceptable range and bypass is enabled, turn off the ups and it will enter bypass mode. Alarm beeps every two minutes. Lcd display battery test d...

  • Page 28: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 26 warning status description if some errors occur in the ups (but it is still running normally), it will show one more screen to represent the warning situation. In the warning screen, the icon will b...

  • Page 29: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 27 10.- operation: parallel ups ups operation modes for ups in parallel are basically same than described for single ups. However it is important to remark all ups in parallel system must work under sa...

  • Page 30: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 28 11.- ups configuration parameter 1 parameter 2 parameter 3 * this menu is activated by simultaneous selection of “test/up” + “mute/down” keys during 1 second when ups is in bypass mode. * there are ...

  • Page 31: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 29 configuration menu texts text description ena enable dis disable ato auto bat battery ncf normal mode (not cvcf mode) cf cvcf mode sub subtract add add on on off off fbd not allowed opn allow res re...

  • Page 32: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 30 01: output voltage interface setting parameter 3: output voltage you may choose the following output voltage in parameter 3: 208: presents output voltage is 208vac 220: presents output voltage is 22...

  • Page 33: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 31 04: frequency range for bypass interface setting parameter 2: set the acceptable low frequency for bypass. 50 hz system: setting range is from 46.0hz to 49.0hz. 60 hz system: setting range is from 5...

  • Page 34: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 32 09: maximum battery discharge time setting interface setting parameter 3: 000~999: set the maximum discharge time from 0 min to 999 min. Ups will shut down to protect battery if the discharge time a...

  • Page 35: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 33 13: battery voltage calibration interface setting parameter 2: select “add” or “sub” function to adjust battery voltage to real figure. Parameter 3: the voltage range is from 0v to 9.9v and the defa...

  • Page 36: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 34 18: output a voltage calibration interface setting parameter 2: it always shows op.V as output voltage. Parameter 3: it shows the internal measurement value of the output a voltage, and you can cali...

  • Page 37: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 35 12.- error codes, alarms & troubleshooting error / failure codes on lcd when a failure or alarm is detected by the ups, an alarm or error code is presented in front panel lcd. This code or symbol wi...

  • Page 38: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 36 alarm codes on lcd warning code warning description 01 battery unconnected 02 input neutral loss 04 input phase abnormal 07 battery over charge 08 low battery 09 overload 0a fan failure 0b epo enabl...

  • Page 39: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 37 alarm symbols on lcd warning icon (flashing) alarm battery low beeping every second overload beeping twice every second battery unconnected beeping every second over charge beeping every second epo ...

  • Page 40: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 38 troubleshooting problem description probable root cause suggested action * lcd does not show input voltage value * ac input failure alarm active (1 beep / 4s) however ac input source is ok input pow...

  • Page 41: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 39 13.- technical specifications (1/2) online ups 33 series 33 10k 33 20k 33 30k capacity / capacidad 10.000va / 8.000w 20.000va / 16.000w 30.000va / 24.000w input-output / entrada-salida 3ph-3ph 3ph-3...

  • Page 42: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 40 13.- technical specifications (2/2) online ups 33 series 33 10k 33 20k 33 30k indicators / indicadores lcd / pantalla de cristal liquido (lcd) alarm / alarmas acoustic beep alarm / alarma sonora: pr...

  • Page 43: User Manual

    User manual - optima-33 10k / 20k / 30k www.Xmart-ups.Com 150805-optima-33 10k/20k/30k (english) - 41 14.- limited warranty support: if a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved please contact authorized service center or author...