Summary of OPTIMA-RT10-06K

  • Page 1

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 1 ver. 1612.05 english user manual optima rt10 6k/10k ups online double conversion rack / tower installation optima-rt10-06k-230v optima-rt10-10k-230v isotx-06k-opt-rack isotx-10k-opt-rack.

  • Page 2

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 2 technical information on this manual is property of xmart . This manual information cannot be copied or distributed totally or partially without written approval of xmart. Xmart can introduce modifications in their prod...

  • Page 3

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 3 table of contents 1. General safety instructions 2. Safety, quality and performance standards 3. Product description 4. Installation installation individual ups installation parallel ups 5. Operation modes 6. Operation i...

  • Page 4

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 4 1. General safety instructions warning: it is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must start-up,...

  • Page 5

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 5 2. Safety, quality and performance standards safety - low voltage directive (2006/95/ec) ups part 1-1: general & safety ups in accessible areas iec/en 62040-1 electromagnetic compatibility - emc directive (2004/108/ec) u...

  • Page 6

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 6 3. Product description this is an uninterruptible power supply (ups) online double conversion with igbt technology at rectifier and inverter stages. It generates a pure sinewave output free of noise and imperfections for...

  • Page 7

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 7 4. Installation this section of the manual covers installation procedure and instructions for this ups series. Before doing installation you must revise and understand sections related to safety and site conditions. Safe...

  • Page 8

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 8 en-iec 62040-1: external backfeed protection in case backfeed protection is required, an automatic external protection circuitry must be installed to provide this kind of protection to comply with en-iec 62040-1. This ex...

  • Page 9

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 9 site inspection and installation conditions regulations and legal directives it is necessary to check that installation site, wiring and power protection in the installation supplied by end user, fulfill technical parame...

  • Page 10

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 10 site installation this ups can be installed in both vertical format or inside a 19” rack cabinet. 19” rack mounting rack ups must be installed using l-shape type guides for supporting ups weight. Usually this kind of su...

  • Page 11

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 11 vertical mounting ups can be installed in vertical format by using plastic supports (fig 1 & 2). These supports are included inside the box. 2 modules: ups+xbat:.

  • Page 12

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 12 3 modules: ups+xbart+optional isotx.

  • Page 13

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 13 lcd rotation ups display can be rotated 90º for easy reading in both vertical and horizontal installations. To rotate lcd follow next steps: 1- unlatch lcd according to step 1 2- separate lcd from the ups frame 3- rotat...

  • Page 14

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 14 circuit breakers and wiring selection breakers and gauge of the wires used in input and output lines must be rated to drive current values in amps as indicated in below tables. Note every country has its local electrica...

  • Page 15

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 15 4.1 installation: individual ups – terminal block make sure the ups is off before starting the installation. Remember to check all wires to be connected are not powered (including external batteries). Ups + xbat ups wit...

  • Page 16

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 16 ups + xbat + isotx (optional) isotx module is an optional accessory not included with the ups. It provides 2 galvanic isolated outputs 120v each. Ups output is connected to isotx input. Important: when isotx is connecte...

  • Page 17

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 17 isotx outputs configuration isotx outputs can be connected in 3 different configurations according to the needs of the application. Important: when 2 x 120v output configuration is selected, each output can only provide...

  • Page 18

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 18 4.2 installation: parallel ups – terminal block optima t10 & rt10 ups allow connection in parallel up to 3 units. A system based on parallel ups could offer a more reliable protection for the load in case it is dimensio...

  • Page 19

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 19 ac lines: connection diagram optima t10 & rt10 230 and optima t10 & rt10 with optional isotx. Optima rt10 6k/10k ups with 220v output directly from inverter important: it is recommendable all output neutral lines are co...

  • Page 20

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 20 optima rt10 6k/10k + isotx : 1 output x 120vac to provide 1 output in 120vac able to supply 100% of total ups power, 2 individual 120vac outputs must be connected by jumpers in terminal blocks (l1-l2 & n1-n2) as indicat...

  • Page 21

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 21 optima rt10 6k/10k + isotx : 2 x 120vac with this configuration, each output will be able to provide 50% of total ups power. In case of 3 ups, third ups must be connected following same principle. Important: it is recom...

  • Page 22

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 22 optima rt10 6k/10k + isotx : 1 x 220vac to provide 1 output in 220vac able to supply 100% of total ups power, 2 individual 120vac outputs must be connected in series by jumpers in terminal blocks (n1-l2) as indicated in...

  • Page 23

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 23 control cables: connection diagram parallel system requires all ups share some important control information by parallel control cables. There are 2 kind of control cables: shared current & parallel control. They must b...

  • Page 24

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 24 5. Operation modes this is a true on line double conversion ups and it is designed to offer clean, bump-less and highest quality power to your computer related equipment protecting also your valuable data. Power deliver...

  • Page 25

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 25 maintenance bypass from time to time, all ups require some kind of maintenance that can only be performed if ups is powered-off. In that case, an external maintenance bypass switch is actuated to keep system running by ...

  • Page 26

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 26 operation modes lcd screens (230vac) lcd screens for 120v ups models are similar but showing values related to 120v instead of 230v operation mode description lcd standby a- when bypass is not allowed ups output is powe...

  • Page 27

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 27 error/failure mode a- when a failure is detected, ups display error code with alert symbol on screen..

  • Page 28

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 28 6. Operator interface: keyboard & lcd ups front panel is equipped with 4 buttons, 4 leds and a lcd display. Leds description: upsmode bypass line battery fault ups turning on ● ● ● ● bypass active ● ○ ○ ○ normal online ...

  • Page 29

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 29 lcd description lcd can be divided in 6 functional areas: output information: it displays: ac input voltage, dc battery voltage, input frequency (in hz) input information: it displays: ac output voltage, output frequenc...

  • Page 30

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 30 flowchart – ups states & modes this section displays graphically operation mode and state of the ups: (1) : valid ac input detected (2) : battery symbol (3) : converters (rectifier & inverter) (4) : ups output powered (...

  • Page 31

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 31 7. Ups configuration configuration menu allows setting of functions and parameters of the ups. Menu is activated by pressing + at same time during 1 second with ups in stand-by or bypass mode (powered but without activa...

  • Page 32

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 32 configuration menu: this model has configurable functions as listed in below table: 01 output voltage: - for 220v/230v models: operator can select between: 208vac / 220vac / 230vac / 240vac. Factory set to: 230v - for 1...

  • Page 33

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 33 06 eco – input voltage range (vac) function 02: high limit function 03: low limit set values with keys: &  07 eco – input frequency range (hz) function 02: high limit function 03: low limit set values with keys: &  ...

  • Page 34

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 34 14 charger voltage adjustment: ** no modifications recommended – only by technicians ** charger voltage can be adjusted add: for increasing sub: for decreasing set values with keys: &  15 inverter voltage adjustment: ...

  • Page 35

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 35 8. Start-up inspection before start up 1. Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures and damage to ups. 2. Make sure all instructions of installa...

  • Page 36

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 36 parallel ups - start-up mandatory requirements for parallel ups if all these requirements are not complied parallel ups will not be able to be started-up. 1.- maximum quantity of ups for working in parallel is 3 units 2...

  • Page 37

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 37 14.- after confirming all output voltages in all units are similar, output breakers can be set one by one in on position. First ups #1, then #2 and #3. At this moment ac outputs of all ups are connected. 15.- verify the...

  • Page 38

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 38 9. Alarm & error codes / troubleshooting important: all alarm and errors are informed on the lcd by dedicated codes and symbols. Alarms: are usually represented by blinking codes or symbols. Audible alarm beeps are also...

  • Page 39

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 39 error codes error condition error code error symbol dc bus start failure 01 dc bus high 02 dc bus low 03 dc bus unbalanced 04 inverter start failure 11 inverter high voltage 12 inverter low voltage 13 short circuit dete...

  • Page 40

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 40 troubleshooting problem probable cause & solucion short runtime in battery mode low batteries charge: recharge batteries during 4-6 h. Old batteries: batteries must be replaced by new ones alarms probable cause & soluci...

  • Page 41

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 41 10. Software our monitoring software allows user to manage ups and monitoring of all of its features. Main software features are: configuring ups parameters, automatic shutdown for protected pcs (os and files) when long...

  • Page 42

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 42 13. Support & warranty support: if a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved please contact authorized service center or authorized dealer. Batteri...

  • Page 43

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 43 14. Rear panel 1 terminal block (ac input & output) 8 epo: emergency power off port 2 not used 9 parallel control ports: shared current 3 ac input breaker 10 parallel control ports: parallel control 4 connector for ext....

  • Page 44

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 44 15. Specifications (1/2) online - optima rt10 capacity / capacidad input / entrada input voltage / voltaje de entrada input range / rango de entrada frequency range / rango frecuencia phase / fases power factor / factor...

  • Page 45

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 45 15. Specifications (2/2) online - optima rt10 indicators / indicadores lcd / pantalla lcd alarm / alarmas beep alarm / alarma sonora: product size & weight / dimensiones y pesos del equipo d x w x h / prof. X ancho x al...

  • Page 46

    Index user manual - optima rt10 6k/10k www.Xmart-ups.Com ver.161205-ga2 (eng) 46 notas.