Xo XOJ30S User Instructions

Summary of XOJ30S

  • Page 1

    Range hood - user instructions hotte de cuisine - notice d’utilisation campana extractora - manual de utilización usa f e need help? Call our ventilation experts toll free al 800-966-8300 avez-vous besoin d’aide ? Contactez nos experts au numéro gratuit 800-966-8300 ¿necesita ayuda? Póngase en conta...

  • Page 2

    Proof of original purchase date and invoice is needed to obtain service under warranty. Limited 2 year warranty. For 2 years from the original date of purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the hood that fails because of a man...

  • Page 3: English

    - 3 - important safety instructions for residential use only read and save these instructions please read entire instructions before proceeding. Important: save these instructions for the local electrical inspectors use. Installer: please leave these instructions with this unit for the owner. Owner:...

  • Page 4

    - 4 - crepes suzette, cherries jubilee, peppercorn beef flambè). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, filters and grease laden surfa...

  • Page 5

    - 5 - d. Ducted fans must always be vented to the outdoors. E. This unit must be grounded. Warning - to reduce the risk of fire, use only metal ductwork. Warning - under certain circumstances domestic appliances may be dan- gerous. A. Do not check filters with hood working. B. Do not touch the lamps...

  • Page 6: Installa

    - 6 - installa tion p repar ation duct fittings: this hood must use an 6" round duct. It can transition to 3-1/4" x 10" or 3-1/4" x 12" duct. Use this chart to compu- te maximum permissible lengths for duct runs to outdoors. Note: do not exceed maxi- mum permissible equivalent lengths! Maximum duct ...

  • Page 7: Warning Fire Hazard

    - 7 - warning fire hazard never exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal...

  • Page 8: D Sp

    - 8 - h oo d sp ecific ations › front of hood › side of hood › top of hood › mounting height and clearance: product dimensions and clearance xov30s - xov36s...

  • Page 9: Installation Instructions

    - 9 - fig.1 fig.2 installation instructions installation - vented to the outside 1. Mount to the wall: drill the holes a respecting the distances indicated (fig.1). Fix the appliance to the wall and align it in horizontal position to the wall units. When the appliance has been adju...

  • Page 10: Power Supply:

    - 10 - power supply: important – (please read carefully) warning: for personal safety, this appliance must be properly grounded. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow national electrical codes...

  • Page 11

    - 11 - 2. Connect electrical: warning - to reduce the risk of fire, electric shock, or injury to per- sons, observe the following: before making electrical connections to power supply, the electrical box must be secured in place as indicated in fig.3. Before installing the appliance fix the electric...

  • Page 12

    - 12 - fig.4 fig.5 • power supply connection: for connection to the power supply refer to the following fig.4-5: 1. Remove the power supply cover by undoing the (2) screws fig.4-5a. 2. Break through the hole on the box cover. 3. Secure the power supply conduit to the cover. 4. Connect the wi...

  • Page 13

    - 13 - fig.6 3. Connect the ductwork: - carry out the power supplly connection in accordance with the national electric code, ansi/nfpa 70-1999. 5. Insert the wires into the box, then close the box cover, securing it using the screws that were previously removed. The appliance ...

  • Page 14

    - 14 - 4. Install the duct cover: arrange the electrical power supply within the dimensions of the decorative flue. If your appliance is to be installed in the ducting version or in the version with external motor, prepare the air exhaust opening. Adjust the width of the support bracket of the upper...

  • Page 15: ���

    - 15 - ductless recirculating option: carbon filter kit xorfk03 (36" - 42"): we have an air diverter a, 12 screws b, 4 rectangular filters c and the bracket d. Carbon filter kit xorfk02 (30"): we have an air diverter a, 10 screws b, 2 rectangular filters c and...

  • Page 16: �

    - 16 - fig.4: take the air diverter a and drill two holes as shown in the figure (hole diameter: 1/4" inches). Once the two holes have been drilled, fasten the air diverter a to the bracket h. Fig.3: put toge...

  • Page 17: �

    - 17 - fig.5: fasten the air diverter permanently to the wall with a screw (the hole previously drilled in fig.2). Fig.6: once the air diverter has been inserted into the bracket and fastened to the wall connect the flexible (6" round flexi...

  • Page 18: ���

    - 18 - fig.9: take the bracket d and fasten it to the hood using the 10 screws b (provided). Take the 2 rectangular filters c and apply them onto the bracket d as shown in the figure. Fig.10: take the bracket d and fasten it to the hood using the 12 screws...

  • Page 19: �

    - 19 - fig.11: put the aluminum panels back in place (fig.8)..

  • Page 20: Maintenance

    - 20 - maintenance •we recommend that the cooker hood is switched on before any food is cooked. We also recommend that the appliance is left running for 15 minutes after the food is cooked, in order to thoroughly eliminate all contaminated air. The ef- fective performance of the cooker hood depends ...

  • Page 21

    - 21 - - do not allow deposit to remain for long periods of time. - do not use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust. - do not allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for...

  • Page 22: Fuse

    - 22 - fuse • the halogen lamps circuit is controlled by a fuse 5x20 mm, 125v 5a. In case of necessity it can be replaced only by spe- cialized personnel. • replacing halogen light bulbs: in order to replace the dichroic lamps, carefully remove the lamp from the lamp holder with the help of a small ...

  • Page 23: Xov30S - Xov36S - Xov42S:

    - 23 - xov30s - xov36s - xov42s:.

  • Page 24: ���

    - 24 - options and accessories: model xorfk02 ductless recirculating filter kit. Model xorfk03 ductless recirculating filter kit..

  • Page 25

    - 25 - model xoedcv - duct cover extension. This accessory is available for installation with ceiling heights above 9 ft to 10 ft..

  • Page 26: Installation Preparation:

    - 26 - installation preparation: check installation hardware: locate the hardware package packed with the hood and check contents. Duct bracket aluminum filter 2-piece decorative duct cover (dimension shown for reference only) type description n° a 1/8" x 1/2" scr...

  • Page 27: Xov Spec Sheet

    - 27 - xov spec sheet model: xov30s - xov36s - xov42s sizes: 30"- 36"- 42" depth: 24" features and benefits: - premium 700 cfm (ebm) high velocity, whisper quiet blower optimally removes smoke, grease and odors. - illuminated touch controls with 3 level light dimmer. - two 50 w halogen lights - prov...