Xo XOM30G User Instructions

Summary of XOM30G

  • Page 1

    Range hood - user instructions hotte de cuisine - notice d’utilisation campana extractora - manual de utilización usa f e xom30g xom36g need help? Call our ventilation experts toll free al 800-966-8300 avez-vous besoin d’aide ? Contactez nos experts au numéro gratuit 800-966-8300 ¿necesita ayuda? Pó...

  • Page 2

    Proof of original purchase date and invoice is needed to obtain service under warranty. Limited 2 year warranty. For 2 years from the original date of purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the hood that fails because of a man...

  • Page 3: English

    - 3 - important safety instructions for residential use only read and save these instructions please read entire instructions before proceeding. Important: save these instructions for the local electrical inspectors use. Installer: please leave these instructions with this unit for the owner. Owner:...

  • Page 4

    - 4 - crepes suzette, cherries jubilee, peppercorn beef flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, filters and grease laden surf...

  • Page 5

    - 5 - d. Ducted fans must always be vented to the outdoors. E. This unit must be grounded. Warning - to reduce the risk of fire, use only metal ductwork. Warning - under certain circumstances domestic appliances may be dan- gerous. A. Do not check filters with hood working. B. Do not touch the lamps...

  • Page 6: Installa

    - 6 - installa tion p repar ation duct fittings: this hood must use an 6" round duct. It can transition to 3-1/4" x 10" or 3-1/4" x 12" duct. Use this chart to compu- te maximum permissible lengths for duct runs to outdoors. Note: do not exceed maxi- mum permissible equivalent lengths! Maximum duct ...

  • Page 7: Warning Fire Hazard

    - 7 - warning fire hazard never exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal...

  • Page 8: D Sp

    - 8 - h oo d sp ecific ations › front of hood › side of hood › top of hood › mounting height and...

  • Page 9: Installation Instructions

    - 9 - fig.1 fig.2 installation instructions installation - vented to the outside 1. Mount to the wall: drill the holes a respecting the distances indicated (fig.1). Fix the appliance to the wall and align it in horizontal position to the wall units. When the appliance has been ad...

  • Page 10: Power Supply:

    - 10 - power supply: important – (please read carefully) warning: for personal safety, this appliance must be properly grounded. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow national electrical codes...

  • Page 11

    - 11 - 2. Connect electrical: warning - to reduce the risk of fire, electric shock, or injury to per- sons, observe the following: before making electrical connections to power supply, the electrical box must be secured in place as indicated in fig.3 before installing the appliance fix the electrica...

  • Page 12

    - 12 - fig.5 fig.4 • power supply connection: for connection to the power supply refer to the following fig.4: 1. Remove the power supply cover by undoing the (2) screws fig.4. 2. Break through the hole on the box cover. 3. Secure the power supply conduit to the cover. 4. Conne...

  • Page 13

    - 13 - 4. Install the duct cover: arrange the electrical power supply within the dimensions of the decorative flue. If your appliance is to be installed in the ducting version or in the version with external motor, prepare the air exhaust opening. Adjust the width of the support bracket of the upper...

  • Page 14: �

    - 14 - ductless recirculating option: fig.1: remove the 2 screws e and have the top flue f go into the bottom flue g. Remove the two flues f-g and place them on a flat surface. Carbon filter kit xorfk01: the kit includes an air diverter a, 2 screws and 2 expan- sion...

  • Page 15: �

    - 15 - fig.3: put together the two parts of the air deviator as shown in picture no 3.1. It may be neces- sary to cut the deviator to fit the width of the chimney as shown in picture 3.2. A sharp blade or hacksaw is recommended to trim the plastic. Fig.4: take the air...

  • Page 16: �

    - 16 - fig.7: place the bottom flue g on top of the frame. Then pull out the top flue f to the bracket and fasten it using the 2 screws e. Fig.8: remove the aluminum panels by pulling the lever 1 out and pushing downwards 2. Fig.9: the charcoal fi lters c must be fit- ted i...

  • Page 17: Use

    - 17 - use • if the apparatus is equipped with the following controls luminous: a = light b = off c = speed i d = speed ii e = speed iii f = automatic stop timer - 15 minutes (*) • if your appliance does not have the intensive speed function, press key e for two seconds and it will be activated for ...

  • Page 18: Maintenance

    - 18 - maintenance •we recommend that the cooker hood is switched on before any food is cooked. We also recommend that the appliance is left running for 15 minutes after the food is cooked, in order to thoroughly eliminate all contaminated air. The ef- fective performance of the cooker hood depends ...

  • Page 19

    - 19 - - do not allow deposit to remain for long periods of time. - do not use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust. - do not allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for...

  • Page 20: Fuse

    - 20 - fuse • the halogen lamps circuit is controlled by a fuse 5x20 mm, 125v 5a. In case of ne- cessity it can be replaced only by special- ized personnel. • replacing halogen light bulbs: to replace the halogen light bulbs b, remove the glass panel c using a lever action on the relevant cracks. Re...

  • Page 21: Xom30G - Xom36G:

    - 21 - xom30g - xom36g:.

  • Page 22: Options and Accessories:

    - 22 - options and accessories: model xorfk01 ductless recirculating filter kit. Model xoedcm - duct cover extension. This accessory is available for installation with ceiling heights above 9ft to 10 ft..

  • Page 23: Installation Preparation:

    - 23 - type description n° a 1/8" x 6/8" screws for attaching the decorative flue to the mounting bracket. 2 b 1/8" x 6/8" screws for attaching the decorative flue to the mounting bracket. 6 duct bracket aluminum filter 2-piece decorative duct cover (dimension shown for reference only) ...

  • Page 24: Xom Spec Sheet

    - 24 - xom spec sheet model: xom30g - xom36g sizes: 30"-36" depth: 19-5/16" features and benefits: - 600 cfm high velocity blower optimally removes smoke, grease and odors. - 4 speed electronic illuminated controls. - two 20 w halogen lights. - aluminum mesh filters - trap airborne smoke and grease ...