Xpelair XHR150HP Installation Instructions Manual

Manual is about: Heat Recovery Ventilator

Summary of XHR150HP

  • Page 1

    Remote control transformer note: the transformer unit should be connected to the mains supply through a fused double pole isolating switch maximum 5 amps. Min 6 inches installation instructions if working above ground floor level, appropriate safety precautions must be observed. Warning eye protecti...

  • Page 2

    2 low voltage output mains input slow/fast fan trickle speed fuses factory sealed do not adjust light level sensor adjuster (see page 8) thumb wheel humidity level adjuster (see page 1) mains l e d pull cord l e d pull cord switch (manual trickle boost control) isolating transformer (humidity sensor...

  • Page 3

    Sitting the ventilator do not install where ambient temperatures are likely to exceed 40 o c (104 o f). ◆ this electrical product, if installed in a shower room or bathroom, must be situated so that they cannot be touched by the person using the bath or shower. ◆ when intended for use in possible ch...

  • Page 4

    Max 1.5° or 8mm pack here installation 1. Check that the electrical rating shown on the inside of the product matches the main supply 2. Check there are no buried pipes or cables e.G. Electricity, gas, water behind the switch location (in wall or above the ceiling) 3. Isolate the mains supply c) you...

  • Page 5

    Inside installation of the finisher ring proceed as follows: i) push the large tube through the hole so it extends some 50mm beyond the face of the outside wall. Ii) apply silicon mastic around the rear face of the split finisher – do not compress the adhesive. Ensure exterior brickwork is dust free...

  • Page 6

    6 try to cut it as evenly as possible with minimum offset. File or otherwise finish your cut end to remove any offset and swarf. J) mounted on the heat exchanger is a round plastic baffle which secures the air intake filters. The extraction fan adjacent to these filters goes to the outside wall. Use...

  • Page 7

    7 fan wall wall transformer note: this part must not be mounted in the interior of a bath tub or shower basin and must be positioned out of reach of a person using a fixed bath or shower. It should be also positioned away from any source of water spray. Location of the transformer unit 1. Check that...

  • Page 8

    N) follow the line diagram below to make the correct connections between the fan assembly and the transformer/humidity sensor, and wall plate. O) place the fan assembly and front cover through the wall plate and push home. Apply power to the system and check operation. Conduct a smoke test to ensure...

  • Page 9

    9 light level sensor a light level sensor is included to prevent the fan from switching automatically to boost at night-time. This is a useful feature particularly if the heat recovery ventilator is installed in a bedroom or bed-sit accommodation, ensuring noise is kept to a minimum. The sensor is f...

  • Page 10

    10 do’s and don’ts • do read the entire instruction leaflet before commencing installation. • do install the transformer with a double pole isolating switch. • do make sure that the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning...