  • Page 1

    Operation manual hk070f hk125fw hk175fw hk215fw kerosene forced air heater.

  • Page 2: Safety

    2 safety 6 safety rules 7 safety warnings 10 unpacking features 11 features of model hk070f 11 features of models hk125fw/hk175fw assembly 12 hardware components 12 frame components for models hk125fw/ hk175fw/hk215fw 13 attaching handle for model hk070f 13 assembly cord wrap 13 assembly frame and w...

  • Page 3: Exploded View

    3 exploded view 28 exploded view parts list 29 hk070f 31 hk125fw 33 hk175fw 35 hk215fw parts list 37 model hk070f 37 model hk125fw/hk175fw/hk215fw warranty 38 limited warranty table of contents.

  • Page 4

    4 using the operator’s manual the operating manual is an important part of your heater and should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed. Reading the owner’s manual thoroughly will help avoid any personal inj...

  • Page 5

    5 product identification record identification numbers heater if you need to contact an authorized dealer or customer service line (1- 866-770-1711) for information on servicing, always provide the product model and identification numbers. You will need to locate the model and serial number for the ...

  • Page 6

    6 safety the safety alert symbol ( ) is used with a signal word (danger, caution, warning), a pictorial and/or a safety message to alert you to hazards. Danger indicates a hazard which, if not avoided, will result in death or serious injury. Warning indicates a hazard which, if not avoided, could re...

  • Page 7: Warning

    7 safety warning • fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by these instructions. Never use the heater in spaces which do or may contain volatile or airborne combustible...

  • Page 8: Warning

    8 safety warning risk of electric shock! • use only the electrical power (voltage and frequency) specified on the model plate of the heater. Use only a three- prong, grounded outlet and extension cord. • always install the heater so that it is not directly exposed to water spray, rain, dripping wate...

  • Page 9: Warning

    9 safety warning risk of burns/fire/explosion! • never use fuels such as gasoline, benzene, paint thinners, or other oil compounds in this heater (risk of fire or explosion). • never refill the heater’s fuel tank while heater is operating or still hot. This heater is extremely hot while in operation...

  • Page 10

    10 safety unpacking remove the heater and all of the packaging materials from the shipping carton. Note: save the box and packaging materials for future storage. Check the chart below to be sure that you have all of the parts required to assembly your heater. If you find that any parts are missing, ...

  • Page 11: Kerosene User’S Manual

    11 features © 2012, pinnacle products international, inc. 3 kerosene user’s manual never leave heater unattended while burn- ing or while connected to a power source safety information (continued) simply locate fan in safe, desired position on level ground, and connect to approved power source. - ge...

  • Page 12: Assembly

    12 assembly assembly hardware components hk070f hk125fw hk175fw hk215fw wheel support frame no yes yes yes wheel (2 pieces) no yes yes yes front and rear handle no yes yes yes axle no yes yes yes top handle yes no no no screws & nuts (a) 8 each no yes yes yes screws & nuts (b) 4 each yes no no no wh...

  • Page 13

    13 attaching handle for model hk070f assembly cord wrap assembly frame and wheels models hk125fw/hk- 175fw/hk215fw assembly tools required: medium phillips screw driver. 1. Align the holes in the upper housing with the 2 holes in the handle. 2. Insert and tighten screws securely with screw driver. 1...

  • Page 14: Caution

    14 assembly assembly cord wrap 1. Align holes in cord wrap with corresponding holes in rear handle. In- sert screws (b) through holes, attach nuts and tighten (see figure 7). Models pt-45/70t-kfa only - tools required: medium phillips screw driver. Assembling handle 1.Align the holes in the upper ho...

  • Page 15: Operation

    15 operation operation kerosene (1-k) for optimal performance of this heater, it is strongly suggested that 1-k kerosene be used. 1-k kerosene has been refined to virtually eliminate contaminants, such as sulfur, which can cause a rotten egg odor during the operation of the heater. However, #1 or #2...

  • Page 16: Kerosene User’S Manual

    16 operation air system: a fan is turned by the heavy duty motor, which forces air around and into the combustion chamber, where it is super-heated and forced out the front of the chamber. Temperature limit control: this heater is equipped with a temperature limit control designed to turn the heater...

  • Page 17: Warning

    17 operation ventilation staring the heater risk of indoor air pollution. Use heater only in well ventilated areas. Always provide a fresh air opening in the heated space of at least three square feet (2,800 sq. Cm) for each 100,000 btu/hr. Of heater output. Provide a larger opening if more heaters ...

  • Page 18: Notice

    18 operation simply turn the power switch to “off” position and unplug the power cord. 1. Wait ten seconds after shutting off heater. 2. Turn the power switch to “on” position. 3. Be sure to follow all starting procedure precautions. Stopping the heater restarting the heater electrical outlet notice...

  • Page 19: Operation (Continued)

    19 operation drain fuel tank for models hk070k, drain fuel through the fuel cap opening using an ap- proved siphon. For models hk125fw/hk175fw/hk215fw drain fuel through the drain plug at the bottom of the fuel tank. 1. To remove the drain plug (125/175/215), pull the plug grip down- ward and remove...

  • Page 20

    20 operation 3. Using a small amount of kerosene, rinse and swirl the kerosene inside of the fuel tank. Empty the tank fully. 4. To replace, push the drain head fully into the drain hole and secure by pushing the seal cap fully into the head hole (see figure 12). Important: never store leftover kero...

  • Page 21: Maintenance

    21 maintenance maintenance use only original equipment replacement parts. The use of alternate or third party components can cause unsafe operating conditions, and will void your warranty. We suggest following a maintenance schedule as follows: fuel/fuel tank: flush every 200 hours of operation or a...

  • Page 22: Notice

    22 maintenance notice use of diesel may require additional maintenance. Using this heater without proper maintenance or with contaminated or old fuel may lead to improper combustion and possible soot production. Be sure fuel used is approved (see operation on page 6). Nozzles: nozzles should be clea...

  • Page 23: Maintenance (Continued)

    23 maintenance spark plug: clean and re-gap every 600 hours of operation, or replace as needed. After removing the spark plug, clean the terminals with a wire brush. Re- gap the terminals to 0.140” (3.5mm). Photocell: the photocell should be cleaned at least once per heating season or more depending...

  • Page 24: Notice

    24 maintenance notice to remove the filter from model hk070f, turn filter 90° clockwise. To remove the filter from models hk125fw/hk175fw/hk215fw, turn filter 90° counter-clockwise. Fuel filter: the fuel filter should be cleaned at least twice per heating season by rinsing it in clean 1-k kerosene. ...

  • Page 25: Maintenance (Continued)

    25 maintenance pump pressure adjustment: while heater is operating, turn relief valve clockwise to increase, counterclockwise to decrease (see figure 20). Use flat blade screwdriver to turn valve. Correct pump pressure is as follows: for best measurement of pressure, test with full tank of fuel. Opt...

  • Page 26: Troubleshooting

    26 troubleshooting problem possible case solution heater fires, but main pcb shuts heater off after a short period of time. Lamp is flickering, and led display shows “e1”. 1. Incorrect pump pressure. 2. Dirty input, output or lint filter. 3. Dirty fuel filter. 4. Nozzle is dirty. 5. Photocell lens i...

  • Page 27

    27 troubleshooting problem possible case solution poor combustion and / or excess soot production. 1. Dirty input, output or lint filter. 2. Dirty fuel filter. 3. Poor quality of fuel. 4. Psi is too high or too low. 1. Clean/replace air filter (p.9) 2. Clean/replace fuel filter (p.10) 3. Be sure fue...

  • Page 28: Exploded View

    28 exploded view exploded view never leave heater unattended while burn- ing or while connected to a power source © 2012, pinnacle products international, inc. 12 kerosene user’s manual exploded view figure 21: exploded view for models pt-45 / 70t / 125t / 175t / 215t-kfa (125/175/215 only) (70 only...

  • Page 29: Parts List

    29 parts list parts list hk070f item # description hk070f 1 fuel tank assembly 70-002-0100 2 drain plug – 3 fuel gauge assembly 70-007-0115 4 fuel filter assembly 70-003-0100 5 fuel cap 70-006-0100 6 power cord 70-034-0100 7 power switch 70-038-0100 8 window display – 9 thermostat control knob 70-03...

  • Page 30

    30 parts list item # description hk070f 39 capacitor 70-020-0125 40 fan assembly 70-024-0200 41 ignitor 70-037-0300 42 right side cover 70-008-0200 43 left side cover 70-009-0100 44 fan guard 70-016-0700 45 main pcb assembly 70-027-0200 46 fuse 70-027-0101 47 clip nut 70-001-0105 48 upper shell – 49...

  • Page 31

    31 parts list hk125fw item # description hk125fw 1 fuel tank assembly 70-002-0200 2 drain plug 70-002-0105 3 fuel gauge assembly 70-007-0210 4 fuel filter assembly 70-003-0200 5 fuel cap 70-006-0100 6 power cord 70-034-0200 7 power switch 70-038-0100 8 window display 70-040-0100 9 thermostat control...

  • Page 32

    32 parts list item # description hk125fw 41 ignitor 70-037-0300 42 right side cover 70-008-0300 43 left side cover 70-009-0200 44 fan guard 70-016-0200 45 main pcb assembly 70-027-0300 46 fuse 70-027-0101 47 clip nut 70-001-0105 48 upper shell – 49 storage box 70-053-0100 50 bushing grommet 70-017-0...

  • Page 33

    33 parts list hk175fw item # description hk175fw 1 fuel tank assembly 70-002-0300 2 drain plug 70-002-0105 3 fuel gauge assembly 70-007-0210 4 fuel filter assembly 70-003-0200 5 fuel cap 70-006-0100 6 power cord 70-034-0200 7 power switch 70-038-0100 8 window display 70-040-0100 9 thermostat control...

  • Page 34

    34 parts list item # description hk175fw 41 ignitor 70-037-0300 42 right side cover 70-008-0400 43 left side cover 70-009-0300 44 fan guard 70-016-0200 45 main pcb assembly 70-027-0300 46 fuse 70-027-0101 47 clip nut 70-001-0105 48 upper shell – 49 storage box 70-053-0100 50 bushing grommet 70-017-0...

  • Page 35

    35 parts list hk215fw item # description hk215fw 1 fuel tank assembly 70-002-0300 2 drain plug 70-002-0105 3 fuel gauge assembly 70-007-0215 4 fuel filter assembly 70-003-0200 5 fuel cap 70-006-0100 6 power cord 70-034-0200 7 power switch 70-038-0100 8 window display 70-040-0100 9 thermostat control...

  • Page 36

    36 parts list item # description hk215fw 41 ignitor 70-037-0300 42 right side cover 70-008-0450 43 left side cover 70-009-0300 44 fan guard 70-016-0220 45 main pcb assembly 70-027-0300 46 fuse 70-027-0101 47 clip nut 70-001-0105 48 upper shell – 49 storage box 70-053-0100 50 bushing grommet 70-017-0...

  • Page 37: Wiring Diagrams

    37 wiring diagrams wiring diagrams model hk070f never leave heater unattended while burn- ing or while connected to a power source wiring diagrams figure 22: model pt-45-kfa figure 23: model pt-70t-kfa figure 23: model pt-125t / 175t / 215t- kfa © 2012, pinnacle products international, inc. 14 keros...

  • Page 38

    38 warranty limited warranty x-stream warrants this heater to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with th...

  • Page 39

    39 x-stream assumes no responsibility for any defects caused by third parties. This limited warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or conse...

  • Page 40

    40 if you need assistance with the assembly or operation of this heater please call 1-866-770-1711.