Yaesu FT-270E Technical Supplement - Alignment
12
FT-270R/E Technical Supplement
Alignment
CTCSS TX Deviation
1. Rotate the DIAL knob to select the display to “B0206,”
then activate the CTCSS encoder with a “100 Hz” tone,
and set the transmit power level to “LOW.”
2. Press the [F/W] key, then press the [MR/MW(SKIP)]
key to set the alignment parameter to “A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx.”
3. With in five second of appearing the “A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx” on
the display, press the PTT switch to activate the trans-
mitter (with no microphone input), adjust the DIAL
knob so that the deviation meter reading is 0.7 kHz
(±0.05 kHz).
S-meter Sensitivity
1. Rotate the DIAL knob to select the display to “B0206.”
2. Inject a 146.050 MHz signal at a level of –5 dBμV (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
3. Press the [F/W] key, then press the [MR/MW(SKIP)]
key to set the alignment parameter to “A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U/D
D
D
D
D.”
4. With in five second of appearing the “A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U/D
D
D
D
D” on
the display, press the [(MHz)] key.
5. Increase the RF signal generator output level to +23
dBμV.
6. Press the [F/W] key to recall the alignment parameter
to “A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U/D
D
D
D
D.”
7. With in five second of appearing the “A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U/D
D
D
D
D” on
the display, press the [(MHz)] key.
Squelch Sensitivity
1. Rotate the DIAL knob to select the display to “B0206.”
2. Inject a 146.050 MHz signal at a level of –12 dBμV (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
3. Press the [F/W] key, then press the [MR/MW(SKIP)]
key to set the alignment parameter to “A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U/D
D
D
D
D.”
4. With in five second of appearing the “A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U/D
D
D
D
D” on
the display, press the [(MHz)] key.
5. Increase the RF signal generator output level to –3
dBμV.
6. Press the [F/W] key to recall the alignment parameter
to “A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U/D
D
D
D
D.”
7. With in five second of appearing the “A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U
A7 SQL U/D
D
D
D
D” on
the display, press the [(MHz)] key.
DC Voltmeter
1. Set the power supply voltage to 9.9 V.
2. Press the [F/W] key, then press the [MR/MW(SKIP)]
key to set the alignment parameter to “A8 BAT RV
A8 BAT RV
A8 BAT RV
A8 BAT RV
A8 BAT RV.”
3. With in five second of appearing the “A8 BAT RV
A8 BAT RV
A8 BAT RV
A8 BAT RV
A8 BAT RV” on
the display, press the [REV(HOME)] key.
To close the alignment mode
1. Turn the power off by rotating the [VOL/PWR] knob
fully counter clockwise.
2. The next time the transceiver is turned on, press and
hold in the [VFO(PRI)] key turning the radio on. Once
the radio is on, release the key.