- DL manuals
- Yale
- Door locks
- AYRD110
- Installation And Programming Instructions
Yale AYRD110 Installation And Programming Instructions - Handing The Lock
Summary of AYRD110
Page 1
1 p/n -110- - - rev d ayrd standalone inst ful yale real living ® installation and programming instructions key free push button deadbolt b1 l ® x3 #8-32 x 5/16" machine screws x4 #7 wood & #8-32 machine x 20mm combination screws x2 m6x47mm long through bolt failure to follow these instructions coul...
Page 2: Preparing Door
2 p/n -110- - - rev d ayrd standalone inst ful preparing door.
Page 3
3 p/n -110- - - rev d ayrd standalone inst ful o x4 1 d faut e 2-3/8" position 2-3/4" position installing latch & strike plate press pull optional bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism..
Page 4: Installing Keypad Escutcheon
4 p/n -110- - - rev d ayrd standalone inst ful 2 installing keypad escutcheon outside of door inside of door bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism..
Page 5
5 p/n -110- - - rev d ayrd standalone inst ful x2 3 installing interior mounting plate loosen screw to remove cover..
Page 6: Attaching The Cable Assembly
4 attaching the cable assembly 6 p/n -110- - - rev d ayrd standalone inst ful.
Page 7
7 p/n -110- - - rev d ayrd standalone inst ful x3 5 installing interior escutcheon.
Page 8: Testing Operation
8 p/n -110- - - rev d ayrd standalone inst ful testing operation bolt must be in retracted (unlocked) position before installing batteries. Aa !.
Page 9: Handing The Lock
9 p/n -110- - - rev d ayrd standalone inst ful handing the lock press . Press . Press . Enter new master code (4-8 digits). Pin press to complete. After entering the master code, pin press any key to complete handing..
Page 10: Installing Cover
10 p/n -110- - - rev d ayrd standalone inst ful 6 installing cover congratulations, you've installed the yale real living ® key free push button deadbolt b1l! Turn sheet over for programming instructions to customize your product..
Page 11: Programming Instructions
11 p/n -110- - - rev d ayrd standalone inst ful programming instructions low battery warning- flashes red failsafe 9 volt battery connection (use alkaline battery) ! Master code must be created before any further programming. Pin max user codes = 25 warning: changes or modifications to this device, ...
Page 12: Creating Master
1 creating master code pin press press press enter 4-8 digit master code. Pin press 12 p/n -110- - - rev d ayrd standalone inst ful.
Page 13: Creating User
2 creating user codes pin master code must be created first. Pin *max user codes = 25 enter master code pin press enter 4-8 digit code pin press press press press press 13 p/n -110- - - rev d ayrd standalone inst ful.
Page 14: Unlocking Door With
14 p/n -110- - - rev d ayrd standalone inst ful 3 unlocking door with code pin "unlock" enter pin press user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ pin code management (up to 25 users) duplicate if necessary user name user # pin code master user ___ user ___ user...
Page 15
15 p/n -110- - - rev d ayrd standalone inst ful resetting lock to factory default when lock is reset to factory defaults all user codes (including the master code*) are pin deleted and all programming features are reset to original default settings (see "factory default settings"). 1. Remove the bat...
Page 16: Definitions
16 p/n -110- - - rev d ayrd standalone inst ful definitions all code lockout mode: this feature is enabled by the master code. When enabled, it restricts all user (except master) code access. When attempting to enter a code while the unit is in lockout, the keypad flashes 8 pin times and the lock be...
Page 17: Using Master
17 p/n -110- - - rev d ayrd standalone inst ful feature programming through menu mode using master code* pin master code setting pin m m user code registration pin register delete advanced lock settings audio mode n/a all code lockout mode enable enable disable disable user number ( ) 1~25 max pin 4...
Page 18: Programming Troubleshooting
18 p/n -110- - - rev d ayrd standalone inst ful programming troubleshooting symptom suggested action lock does not respond – door is open and accessible. • press each keypad button for response when pressed. • check batteries are installed and oriented correctly (polarity) in the battery case. • che...
Page 19
19 p/n -110- - - rev d ayrd standalone inst ful fcc: this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the rules. These limits are designed to provide reasonable protection against harmful fcc interference in a residential install...
Page 20
20 p/n -110- - - rev d ayrd standalone inst ful yale® and yale real living® are registered trademarks of yale security inc., an group company. Assa abloy copyright © 2017, yale security inc., an group company. Assa abloy all rights reserved. Reproduction in whole or in part without the express writt...