Yale HSA3095 Installation Instruction

Manual is about: Home-monitoring and intruder alarm system

Summary of HSA3095

  • Page 1

    An assa abloy group brand kit 5 home-monitoring and intruder alarm system hsa3095 installation ¥ programming ¥ operating keep in a handy place for reference and for future maintenance helpline 01902 635998.

  • Page 2

    2 introduction general system overview thank you for choosing the yale hsa3095 home-monitoring and intruder alarm system. This simple to install system has been designed with the user in mind. Two window stickers are included in the pack. Please stick them in a front and rear window. No connections ...

  • Page 3

    3 contents contents 1 location planning 4 2 unpack the parts 6 3 easy install programming 8 4 installation/mounting 13 5 testing the system 15 6 monitoring service 16 7 using the system 17 8 configuring your system 20 9 installing and using accessories 23 changing the batteries 24 trouble shooting 2...

  • Page 4

    Location planning work out the best places to locate the devices for maximum protection. Having chosen the locations do not mount at this stage. 4 1 keypad remote control accessory when used as second keypad, it is ideal in bedrooms or at the top of a stairwell so the ground floor can be armed when ...

  • Page 5

    5 smoke detector ¥ mount on the ceiling at the top of a stairwell, or where smoke would most likely be detected. Pir movement detector ¥ mount in a position such that an intruder would normally move across the pirs field of view. ¥ height should be between 1.7 and 2.3 metres above floor level. ¥ loc...

  • Page 6

    Control unit plug the power adaptor into the mains supply wall socket and the other end into the control unit. A long beep will be heard ¥ in addition to the adapter, there is a rechargeable battery inside the control unit that serves as a back up in case of a power failure. When the battery is full...

  • Page 7

    Door/window contact 1 remove the cover by loosening the fixing screw. 2 insert the two aaa batteries as shown. The indicator will flash briefly. 7 + + + 3 a b flood detector unscrew the two screws and insert 12v battery. Note: the detector will not respond to inserting the battery until the learning...

  • Page 8

    7 the system asks you for a new pin code. Think of one you can remember and key it in. Don t forget it, write it in system records page 19. 8 press ok. 9 confirm by keying in your pin code again. 10 press ok. If the incorrect code is entered, a message prompts the previous step. 11 the display now o...

  • Page 9

    9 ¥ when the name is complete, press ok to confirm and return to the previous or main menu. Note the name can be erased by clearing the display by entering backward spaces and pressing ok to delete user pin code ¥ except user #1 which is activated by factory default and can t be deleted in any way, ...

  • Page 10

    10 1 press # (program key), enter your prorgam code and press ok. 2 select devices +/- by scrolling down the program menu and press ok. 3 select add devices and press ok. ¥ display will show push button on device to add . 4 press the learn/test button in the rear of the door/window contact. ¥ the co...

  • Page 11

    11 sound a two-tone confirmation and the control unit will confirm. Please ensure that you test smoke detectors regularly. Add the flood detector 1 enter the devices +/- menu and select the add devices sub menu 2 when prompted by the control unit, bridge the water sensor probes with a coin so that a...

  • Page 12

    12 ¥ with j7 off , jamming by radio interference is detected when continuously present for more than 30 seconds and activates the siren only when armed. 7 replace the battery and electronics compartment covers, ensuring the gasket between the electronics compartment and cover is correctly located an...

  • Page 13

    13 installation/mounting warning to prevent the alarm from activating during installation, the siren must have its tamper disabled and the control unit must be in walk test /program mode. 4 mounting methods yale provide two methods of mounting. Choose either the self adhesive pads or the screws and ...

  • Page 14

    14 ¥ do not position a pir to look directly at a door protected by a door contact, this could cause the door contact and pir radio signals to be transmitted at the same instant when entering, cancelling each other out. ¥ ensure the jumper is in the normal off position when testing is finished, other...

  • Page 15

    Pir sleep feature the pir has a built-in sleep timer to save battery power. If there is no movement in front of the pir for 1 minute, the pir will become ready to signal and movement will now be reported. The pir will sleep for 1 minute after. Any movement detected in sleep time will not be reported...

  • Page 16

    6 16 connecting to the intamac home monitoring tm service connect to the online home monitoring and messaging service, with your free 12 months subscription. Call or register online with intamac telephone intamac on 0845 230 0708 during working hours (mon-thurs 9am-5pm, fri 9am-4pm) or register onli...

  • Page 17

    17 arming the system away arming 1 enter your pin code and press ok. 2 arm and home can be selected by using the arrow keys, select arm . 3 press ok. The exit delay is displayed and counts down from the default setting of 30 seconds. The control unit beeps (unless exit sound has been switched off). ...

  • Page 18

    18 system will sound an alarm. 1 key in your pin code, and then press ok, the audible alarm will stop. ¥ if the alarm is silenced before reporting has finished the control panel will show reporting - - - pls wait and you will be prompted to press ok to carry on, when the reporting is finished. 2 the...

  • Page 19

    19 a tamper alarm when the system is disarmed. To enable the display to be cleared a tamper condition has to be rectified. For example, if a detector has been tampered the display can only be cleared once the detector tamper has been closed. The display is cleared by entering your pin code, pressing...

  • Page 20

    8 20 configuring your system fine tune the operation of the control panel to your requirements; advanced programming for pirs and door/window contacts. General settings menu pin code to change pin code, follow steps in easy install programming . Temporary code to change temporary code, see steps in ...

  • Page 21

    21 3 now the day will flash, use arrow keys to select the day. 4 press ok to confirm. Note: date will be reset if all power to the unit is lost. Panel siren allows you to set the duration of the siren from disabled (silent) to 15 minutes in 1 minute steps. 1 use arrow keys to switch between options....

  • Page 22

    Armed or home mode points for consideration ¥ in home mode, detectors set as burglar will cause an alarm when activated, whilst detectors set as home omit will not trigger an alarm. ¥ if the system is fully or home armed, detectors set as entry will start the entry countdown when activated. When dis...

  • Page 23

    23 9 keyfob remote control accessory programming learn in the keyfob as follows: 1 enter the devices +/- menu and select the add device sub menu. 2 press the arm button on the keyfob remote when prompted and confirm it is the correct detector by pressing ok. 3 after you have assigned a zone number f...

  • Page 24

    24 changing the batteries always use alkaline batteries as replacements, any other type of battery can cause problems with the operation of the system. Typical life of batteries is three years. Ensure the correct steps are taken when changing batteries in tamper protected devices. Siren the siren wi...

  • Page 25

    25 trouble shooting siren siren does not respond to arming or disarming ¥ siren batteries are completely exhausted. Check siren batteries by removing siren cover, if there is no tamper alarm when removed, replace batteries with new alkaline equivalents. ¥ siren not learnt-in. If siren produces a tam...

  • Page 26

    26 specifications all devices emc tested to en 300 220-1 and ets 300 683 environmental conditions -10¡ c to 40¡ c, relative humidity 70% non-condensing for all units except the external siren. Siren: -20¡ c to 50¡ c, relative humidity 95% non-condensing radio operational range 30m in a typical domes...

  • Page 27

    27.

  • Page 28

    28 key points stopping the alarm ¥ key in your pin code and press ok on the control panel if any of the devices beep or flash, they have either been tampered with see trouble-shooting, page 25 or require a new battery see how to change a battery, page 24 yale the meadows, cannock road, wolverhampton...