Yale RH00436G Use, Care, And Installation Manual Model Number

Summary of RH00436G

  • Page 1

    Use, care, and installation guide model number: serial number: jan11.0201 rh00436g rh00436s.

  • Page 3: Able of Contents

    1 safety notice ................................................................. 2-3 list of materials ....................................................... 4 installation ducting calculation sheet ....................................... 5 mounting height & clearance ................................

  • Page 4: Important Safety Notice

    Important safety notice read and save these instructions 2 warning to reduce the risk of fire or electric shock, do not use this fan with any solid-state control device. Warning to reduce the risk of fire electric shock, or injury to persons, observe the following: a. Use this unit only in the manne...

  • Page 5: Important Safety Notice

    Important safety notice 3 warning to reduce the risk of fire, use only metal ductwork. Not for use in outdoor cooking environments. Caution to reduce risk of fi re and to properly exhaust air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. Operat...

  • Page 6: List of Materials

    List of materials 4 (3) wire nuts (1) suction cup (4) 6 x 1-1/2” (wood screws) (2) m4 x 8 (top support frame screws) (1) m4 x 12 (safety screw) (12) m3 x 6 (duct cover screws) 1 - hardware package 2 - thick trim pieces 2 - thin trim pieces 1 - top support frame 1 - bottom support frame 2 - top duct ...

  • Page 7: Installation –

    5 duct pieces total equivalent number length x used = 3- 1/ 4” x 10” rect., straight 1 ft. X ( ) = ft. 8” round, straight 1 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 90 0 elbow 15 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 45 0 elbow 9 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 90 0 flat elbow 24 ft. X ( ) = ft. 3- ...

  • Page 8: Installation –

    Installation – mounting height & clearance 6 ducting a minimum of 6” round duct must be used to maintain maximum air fl ow effi ciency. Always use rigid type metal ducts only. Flexible ducts could restrict air fl ow by up to 50%. Use calculation worksheet to compute total duct work (page 5). Always, wh...

  • Page 9: Installation –

    7 warning fire hazard never exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal scr...

  • Page 10: Installation –

    8 installation – hood specifi cations front side top of hood top support frame (top view) 10 3/8 ” 23 15/16 ” 35 3/16 ” 25 9/16 ” 24 1/2 ” 3 9/16 ” 10 3/4 ” 2 3/4 ” 11 5/8 ” 4 3/8 ” min. Ducted - 28” min. Recirc. - 28” maximum - 38” (top of electrical box) 13 3/4 ” 5/16 ” c/l 6” elec. K/o 8 3/4 ” 3 3...

  • Page 11: Installation –

    9 installation – mounting the hood hood is intended to be mounted to a fi nished ceiling. 1. Ceiling preparation: determine hood mounting location and temporarily tape paper template (incluided with the hood) to the ceiling. Cut-out internal shaded area of template to allow the ductng and electrical ...

  • Page 12: Installation –

    10 installation – mounting the hood 5. Remove tape securing electronics mounting bracket to hood. (fig. D, #1) remove (3) screws from top of hood body and set screws aside. Position electronics mounting bracket as show in (fig. D, #2) and secure to hood body using the (3) previously removed screws. ...

  • Page 13: Installation –

    11 fig. G 2 1 3 5 4 top duct covers top support frame bottom duct covers bottom support frame thick trim piece (top) thin trim piece (bottom) cut trim piece if necessary 10. *secure top duct covers (with louver holes) to top support frame using (2) m4 x 8 screws. (fig. G, #1). Note: if using hood in...

  • Page 14: Installation –

    12 ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The ...

  • Page 15: Features & Controls -

    13 blower off lights on/off 1 3 2 blower speed selection blower off the blower will be powered off by pressing: blower speed selection select one of three speed levels by pressing: lights on/off power lights on and off by pressing: 3 features & controls - mechanical controls.

  • Page 16: Maintenance –

    14 surface maintenance: clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive sta...

  • Page 17: Maintenance –

    15 replacing light bulbs caution: light bulb becomes extremely hot when turned on. Do not touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: bulb does not uns...

  • Page 18: Roubleshooting

    16 t roubleshooting troubleshooting procedures issue cause what to do after installation, the unit doesn’t work. 1. The power source is not turned on. 1. Make sure the circuit breaker and the unit’s power is on. 2. The power line and the cable locking connector is not connecting properly. 2. Check t...

  • Page 19: Iring Diagrams

    17 w iring diagrams.

  • Page 20: List of Materials

    List of materials 18 description part# replacement parts light bulb gu-10 50w (each) z0b-0020 optional accessories recirculating kit rhrk004s replacement charcoal filter z0f-c002 duct cover extension (up to 12’ ceiling) rhex004s to order parts, visit us online at www.Ventingservices.Com or call us a...

  • Page 21: Limited Warranty

    1-888-750-1698 staple your receipt here to obtain service under warranty or for any service related questions, please call: venting services (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of range hoods (the “products”) that s...