G
4 Wire Heat Pump
w/o Aux Heat +C
From
Furnace
RH
C
O
Y
B
WIRES:
C B
or
O Y RH G
CA8900 Terminals
Y
B
RH G
C
HEAT PUMP SYSTEM
O
C B O W2 W
Y RH RC G A
or
or
Connect
1.
O wire to the O terminal or B wire to the B terminal
on the CA8900. (If you have both O and B, connect O wire to O
terminal
DO NOT connect B to B terminal. (See page 10 Trane for the B
wire terminal.) This connects the change-over valve.
Connect the
2.
Y wire to Y on the CA8900. This connects the Com-
pressor.
Connect the
3.
R (or RH) wire to RH on the CA8900. This connects
to the 24vac power.
Connect the
4.
G wire to the G terminal on the CA8900. This con-
nects the Fan.
Connect the
5.
C wire to the C terminal on the CA8900. This con-
nects 24vac power.
Set Config jumpers as shown.
6.
Your system is now connected. Continue on page 9.
4 Wire
Heat
Pump
w/o
Aux
+C
1 2 3
4 5
C B
or
O W2 Y R H G
5 Wire
Heat Pump
w/ Aux Heat
+C
From
Furnace
RH
C
O
or
W2
B
G
Y
WIRES:
CA8900 Terminals
Y
W2
B
R G
C
HEAT PUMP SYSTEM
O
C B O W2 W
Y RH RC G A
OPTIONAL POWER
or
or
Connect
1.
O wire to the O terminal or B wire to the B terminal on the
CA8900. If you have both O and B, connect O wire to O terminal.
DO NOT connect B to B terminal. See page 10 Trane for B
wire terminal.
Connect the
2.
W2 wire to W2 on the CA8900.
Connect the
3.
Y wire to Y on the CA8900.
Connect the
4.
R wire to RH on the CA8900.
Connect the
5.
G wire to G on the CA8900.
Connect the
6.
C wire to the C terminal on the CA8900. This con-
nects 24vac power.
Set Config jumpers as shown.
7.
Set jumper 5 if you have Gas
8.
or Oil aux heat.
Your system is now connected. Continue on page 9.
1 2 3
4 5
5 Wire
Heat
Pump
w/ Aux
Heat +C
G
RH
C W2 W Y R H G
1 stage Cool
2 stage Heat
+C
From
Furnace
C
W
Y
W
2
WIRES:
CA8900 Terminals
W2
W Y
RH
G
C
HVAC SYSTEM
C B O W2 W
Y RH RC G A
OPTIONAL
POWER
Connect the
1.
W wire to the W terminal and W2 to W2 on the
CA8900. This connects 2 stages of heat.
Connect the
2.
Y wire to the Y terminal wire on the CA8900. This
connects cool.
Connect the
3.
RH or R wire to the RH terminal on the thermostat. This
connects the Heater/Cool Power.
Connect the
4.
G wire to the G terminal on the Thermostat. This
connects to the Fan.
Connect the
5.
C wire to the C terminal on the CA8900. This con-
nects 24vac power
Set Config jumpers as shown.
6.
If you have Electric heat, set
-
1A.
If you have Gas or Oil, set
-
1B.
Your system is now connected. Continue on page 9.
2 Stage
Heat and
1 Stage
Cool +C
2 3 4 5
1
A