Zanussi Electrolux TCE 7276W Instruction Booklet - page 16
16
Adjusting the level of conductivity
Water contains, a variable quantity of limestone and
mineral salts of which quantities vary according to
geographical locations thus varying its conductivity
values.
Relevant variations of the conductivity of the water
compared to those prefixed by the factory could
slightly influence the residual humidity of the
laundry at the end of the cycle.
Your dryer allows you to regulate the sensitivity of
the drying sensor based on conductivity values of the
water by using the following procedure.
Procedure:
Turn the programme selector dial to switch on the
appliance
In selection mode press simultaneously the buttons 3
and 6 until «
C0
» appears on the digits.
Adjusting the level of
conductivity:
Press the button 5 sequentially: the level of
conductivity is indicated by the lighting of the
horizontal hyphens.
TCE 7276 W
PROGRAMMES
CLOGGED CONDENSER
DRYING
COOLING
END
CLOGGED FILTERS
FULL TANK
START/
PAUSE
DOOR
RELEASE
QUICK
DRY
DELAY
START
NO
BUZZER
LOW
TEMPERATURE
1 2 3 4 5
6
6
X
TRA
C
APACITY
TCE 7276 W
PROGRAMMES
CLOGGED CONDENSER
DRYING
COOLING
END
CLOGGED FILTERS
FULL TANK
START/
PAUSE
DOOR
RELEASE
QUICK
DRY
DELAY
START
NO
BUZZER
LOW
TEMPERATURE
1 2 3 4 5
6
6
X
TRA
C
APACITY
Normally, the appliance is factory-set to the
highest level; however, certain models may be
configured differently.
Memorizing the new
setting:
Simultaneously press down the buttons 3 and 6 until
the previous drying cycle time appears again on the
display and the buzzer sounds.
Display
Conductivity degree
Approximative value
(µS/cm)
C
C 0
0
Low
< 300
C
C 0
0
Medium
300 - 600
C
C 0
0
High
> 600