Zap Zaptruck-XL 2009 Owner's And Operator's Manual - page 16
Owner and Operator’s Manual
TM
-XL
Introduction of Devices and Control Mechanism
7. Multi-Functional Display
It is a automatic reposition button, when the ignition
switch is at the“ON” position,pressing the button will
switch the display mode: electric capacity-power
battery voltage-power battery current-assistant
battery voltage-electric capacity.
The times of the display mode changing and the times
of pressing the button is the same
1) Display Mode Choice Button
2) Screen
The display screen shows the system
information of current module, but also failure
information
When the state of charge module is
working, the display shows state of charge
capacity of current power battery with two
digits 01 to 10 with no unit, the 01 means 10%
of residual electricity and 10 means 100%.
When
the total of discharging energy module is
working, it shows with six digits integral with
unit of kW/h.
When the
discharging current module is working, it shows
current power (ampere) main battery
discharging current wit a four digit number
showing unit of ampere, three digits of the front
number are integral, and the rear number is
decimal.
When the
auxiliary battery voltage module is working, it
shows with three digits the unit of voltage, two
digits of the front number are integral, and the
rear number is a decimal fraction.
When the voltage of the secondary battery is
below 12V, the display emits warning two times,
and does so repeatedly for a sustained amount
of time. This shows the current value and
secondary battery voltage value by turns.
When there is something wrong with the
vehicle, the display emits warning three times,
and displays failure information,such as E-XX.
When there are more than two kinds of
warning, the display emit warning with same
period.
E-04: electrifying neutral checking: when the
vehicle is starting, if the direction choose switch
is at “R” or “F” position, the electric controller
system will output nothing and emit the failure
code to multifunction display. Turn the ignition
switch to “OFF” position, and turn the direction
choose switch to “N” position, and then start
the vehicle,the failure will disappear.
E-09: running logic protection: when the vehicle
is running,the“R” shift and the“F” shift have
(Q) will light up on the Choice
Button.
(W) will light up on the Choice Button.
(A) will light up on the Choice Button.
(U) will light up on the Choice Button.
The following is a sample of part of a failure
code.
NOTE
When there is failure with the vehicle, the
LCD screen of the multi-function display will
show the failure code and current
information alternately.
15
1
2
3
Definition
protection
over voltage
driving voltage- low of IPM or
over current
ow voltage in the control/drive circuit
>75
temperature
battery low
over-speed
over-load of t
relay
running logic protection
service brake valid warning
contactor
setting value
contactor failure
code plate circuitry failure
beforehand charg
failure
current sensor failure
voltage sensor failure
phase fault
accelerator over high
order fault
IGBT failure
motor
-
l
voltage
hermal sensitive
drop voltage beyond
ing loop
starting
℃
Code
E-01
E-02
E-03
E-04
E-05
E-06
E-07
E-08
E-09
E10
E-11
E-12
E-13
E-14
E-15
E-16
E-17
E-18
E-19
Idiographic Failure Code and Information: